Townhouses-LR010618
REPORT OF FIELD /h. COMPACTION TESTS ALPHA TESTING, INC. • 2209 Wisconsin St.,Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 06/18/01 DALLAS, TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-160 COPPELL, TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT' PCF % PCF 2135 06/18/01 FSG 8L 24.0 92.5 25.2 90 97 1-A TEST LOCATION: 2135 ELECTRICAL TRENCH BACKFILL ON INDEPENDENCE (AT POLE RISER) CC: STEVE TOPLETZ,ANDANTE / 1. FILL •A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS R;•- tful• ubm -•� 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST ALPH• ' .T .G, .C. Our test results&reports are for the exclusive use of the Client(and their designated recipients on file in our office)and shall not be reproduced and/or d'•ributed e ept h express approval• ALPHA. The use of our name&test results must receive our written approval. Test results&reports apply only to the samples tested and/or observed,and are not indicative of the•ual' of apparently iden al or similar specimens. Geotechnical Engineering I Construction Materials Testing I Environmental Engineering N Consulting Nik ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, Texas 75229 (972) 620-8911 Report Tested For: LEMP DEVELOPMENT Our Report No.: 00430-138 ATTN: GREG LEMP Issue Date: 06/18/2001 4101 MCGWEN,SUITE 110 DALLAS,TX 75244 Fax Number: (972)404-1833 Project Desc: COPPELL TOWNHOMES COPPELL,TEXAS FIELD DATA Placement Location: PAVING,STATION 4+50 ON COLONIAL DR. Date Placed: 5/17/01 Plant Number: -3600 Time Placed: 3:45 PM Delivery Ticket No.: 21868 Slump(ASTM C-143): 2.5 Made By ALPHA Air Content: 4.4 (ASTM C-173) Air Temperature: 82 Cured Specification: ASTM C-31 Specimen Temperature: 92 Date Received: 5/18/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: FORESE,NICHOLAS Mix Data Submitted By: SITE CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI: 29 LAB C-1231 5/24/01 7 12 N/A 6 28.27 94922 3350 30 LAB C-1231 6/14/01 28 12 N/A 6 28.27 110825 3920 31 LAB C-1231 6/14/01 28 12 N/A 6 28.27 116281 4110 32 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 I Results to Date: PASS L. Notes: Respectfully Submitted By: ,/,, 4 of Alpha Testing,Inc. Our test results and reports are for the exclusive use of the Client(and their designated receplents on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed,and are not Indicative of the qualities of apparently Identical or similar specimens. Geotechnical Engineering*Construction Materials Testing* Environmental Engineering*Consulting 8273 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Concrete Compression Test ���� Dallas, Texas 75229 Report (972) 620-8911 p Tested For: LEMP DEVELOPMENT Our Report No.: 00430-137 ATTN: GREG LEMP Issue Date: 06/18/2001 4101 MCGWEN,SUITE 110 DALLAS,TX 75244 Fax Number: (972)404-1833 Project Desc: COPPELL TOWNHOMES COPPELL,TEXAS FIELD DATA Placement Location: PAVING,STATION 1+07 ON LIBERTY CIRCLE Date Placed: 5/17/01 Plant Number: -3600 Time Placed: 11:45 AM Delivery Ticket No.: 21834 Slump(ASTM C-143): 3 Made By: ALPHA Air Content: 4.6 (ASTM C-173) Air Temperature: 76 Cured Specification: ASTM C-31 Specimen Temperature: 85 Date Received: 5/18/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: FORESE, NICHOLAS Mix Data Submitted By: SITE CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI: 25 LAB C-1231 5/24/01 7 12 N/A 6 28.27 89900 3180 26 LAB C-1231 6/14/01 28 12 N/A 6 28.27 111538 3940 27 LAB C-1231 6/14/01 28 12 N/A 6 28.27 109189 3860 28 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 Results to Date: PASS Notes: Respectfully Submitted By: of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client(and their designated receplents on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed,and are not Indicative of the qualities of apparently Identical or similar specimens. Geotechnlcal Engineering•Construction Materials Testing• Environmental Engineering Consulting 8272 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Concrete Compression Test ���� Dallas, Texas 75229 Report (972) 620-8911 p Tested For: LEMP DEVELOPMENT Our Report No.: 00430-136 ATTN: GREG LEMP Issue Date: 06/18/2001 4101 MCGWEN,SUITE 110 DALLAS,TX 75244 Fax Number: (972)404-1833 Project Desc: COPPELL TOWNHOMES COPPELL,TEXAS FIELD DATA Placement Location: PAVING,STATION 5+60 ON INDEPENDENCE DR. Date Placed: 5/17/01 Plant Number: N/A Time Placed: 9:15 AM Delivery Ticket No.: N/A Slump(ASTM C-143): 2 Made By: ALPHA Air Content: 4.3 (ASTM C-173) Air Temperature: 73 Cured Specification: ASTM C-31 Specimen Temperature: 84 Date Received: 5/18/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: FORESE, NICHOLAS Mix Data Submitted By: SITE CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI: 21 LAB C-1231 5/24/01 7 12 N/A 6 28.27 66495 2350 22 LAB C-1231 6/14/01 28 12 N/A 6 28.27 87699 3100 23 LAB C-1231 6/14/01 28 12 N/A 6 28.27 86800 3070 24 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 LResults to Date: PASS Notes: Respectfully Submitted By: 1,w! L '/ of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client(and their designated receplents on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed,and are not indicative of the qualities of apparently identical or similar specimens. Geotechnlcal Engineering*Construction Materials Testing Environmental Engineering*Consulting 8271 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Concrete Compression Test ���� Dallas,Texas 75229 ors (972) 620-8911 Report Tested For: LEMP DEVELOPMENT Our Report No.: 00430-152 ATTN: GREG LEMP Issue Date: 06/18/2001 4101 MCGWEN,SUITE 110 DALLAS,TX 75244 Fax Number: (972)404-1833 Project Desc: COPPELL TOWNHOMES COPPELL,TEXAS FIELD DATA Placement Location: BOX CULVERT MC 6-16 © STATION 4+00 Date Placed: 6/8/01 Plant Number: 27-4500 Time Placed: 2:30 PM Delivery Ticket No.: 848644 Slump(ASTM C-143): 3.25 Made By: ALPHA Air Content: N/A Air Temperature: 87 Cured Specification: ASTM C-31 Specimen Temperature: 95 Date Received: 6/9/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: JOHNSTON,DARREL Mix Data Submitted By: HANSON CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.ln. Load: PSI: 73 LAB C-1231 6/15/01 7 12 N/A 6 28.27 140833 4980 74 LAB 7/6/01 28 12 N/A 6 28.27 0 75 LAB 7/6/01 28 12 N/A 6 28.27 0 76 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 4000 I Results to Date: N/A Notes: Respectfully Submitted By: A of Alpha Testing,Inc. Our test results and reports are for the exclusive use of the Gient(and their designated recepients on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed,and are not indicative of the qualities of apparently identical or similar specimens. N//i ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, Texas 75229 (972) 620-8911 Report Tested For: LEMP DEVELOPMENT Our Report No.: 00430-151 ATTN: GREG LEMP Issue Date: 06/18/2001 4101 MCGWEN,SUITE 110 DALLAS,TX 75244 Fax Number: (972)404-1833 Project Desc: COPPELL TOWNHOMES COPPELL,TEXAS FIELD DATA Placement Location: BOX CULVERT WALL,LINE A @ STATION 4+00&STATION 3+04.86 Date Placed: 6/6/01 Plant Number: 29-4500 Time Placed: 3:45 PM Delivery Ticket No.: 640282 Slump(ASTM C-143): 5 Made By ALPHA Air Content: N/A Cured Specification: ASTM C-31 Air Temperature: 83 Specimen Temperature: 88 Date Received: 6/7/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: SANDERS,JUSTIN S. Mix Data Submitted By: PIONEER CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI: 69 LAB C-1231 6/13/01 7 12 N/A 6 28.27 125178 4420 70 LAB 7/4/01 28 12 N/A 6 28.27 0 71 LAB 7/4/01 28 12 N/A 6 28.27 0 72 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 _ 4000 Results to Date: N/A Notes: Respectfully Submitted By: 1/ of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client(and their designated recepients on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed,and are not Indicative of the qualities of apparently Identical or similar specimens. Geotechnlcal Engineering`Construction Materials Testing• Environmental Engineering*Consulting 8852