Townhouses-LR010620 ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100 Concrete Compression Test
A Dallas, Texas 75229 Report
(972) 620-8911 p
Tested For: LEMP DEVELOPMENT Our Report No.: 00430-135
ATTN: GREG LEMP Issue Date: 06/20/2001
4101 MCGWEN,SUITE 110
DALLAS,TX 75244
Fax Number: (972)404-1833
Project Desc: COPPELL TOWNHOMES
COPPELL,TEXAS
FIELD DATA
Placement Location: PAVING,FIRE LANE @ STATION 3+00
Date Placed: 5/16/01 Plant Number: N/A
Time Placed: 3:00 PM Delivery Ticket No.: N/A
Slump(ASTM C-143): 2 Made By: ALPHA
Air Content: 5.5 (ASTM C-173)
Air Temperature: 90 Cured Specification: ASTM C-31
Specimen Temperature: 86
Date Received: 5/17/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: GROTBERG,ERIC
Mix Data Submitted By: N/A
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI:
17 LAB C-1231 5/23/01 7 12 N/A 6 28.27 98890 3490
18 LAB C-1231 6/13/01 28 12 N/A 6 28.27 139845 4940
19 LAB C-1231 6/13/01 28 12 N/A 6 28.27 145777 5150
20 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3000 I
Results to Date: PASS
Notes:
Respectfully Submitted By: / /11 !� of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of the Client(and their designated recepients on file in our office)and shall not be reproduced and/or distributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or