Loading...
Townhouses-LR010627 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, Texas 75229 (972) 620-8911 Report Tested For: LEMP DEVELOPMENT Our Report No.: 00430-146 ATTN: GREG LEMP Issue Date: 06/27/2001 4101 MCGWEN,SUITE 110 DALLAS,TX 75244 Fax Number: (972)404-1833 Project Desc: COPPELL TOWNHOMES COPPELL,TEXAS FIELD DATA Placement Location: PAVING,20W&3'N FROM THE NW CORNER OF PAD#21 Date Placed: 5/22/01 Plant Number: -3600 Time Placed: 10:45 AM Delivery Ticket No.: 22286 Slump(ASTM C-143): 4 Made By: ALPHA Air Content: 5.25 (ASTM C-173) Air Temperature: 78 Cured Specification: ASTM C-31 Specimen Temperature: 80 Date Received: 5/23/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: CASANOVA,STEVEN Mix Data Submitted By: SITE CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI: 45 LAB C-1231 5/29/01 7 12 N/A 6 28.27 89514 3160 46 LAB C-1231 6/19/01 28 12 N/A 6 28.27 131110 4630 47 LAB C-1231 6/19/01 28 12 N/A 6 28.27 129859 4590 48 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3600 Results to Date: PASS Notes: Respectfully Submitted By: AI of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client(and their designated receplents on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed,and are not indicative of the qualities of apparently Identical or similar specimens. .° . `" G;t :*r*:j14*Nt ". . la t*j*`,. *t tltllBt* i 1161E t*;C:ott#t It n r.0 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Concrete Compression Test /A Dallas, Texas 75229 Report (972) 620-8911 Re p Tested For: LEMP DEVELOPMENT Our Report No.: 00430-145 ATTN: GREG LEMP Issue Date: 06/27/2001 4101 MCGWEN,SUITE 110 DALLAS,TX 75244 Fax Number: (972)404-1833 Project Desc: COPPELL TOWNHOMES COPPELL,TEXAS FIELD DATA Placement Location: PAVING, 15W&2'N FROM THE NW CORNER OF PAD#18 Date Placed: 5/22/01 Plant Number: -3600 Time Placed: 7:45 AM Delivery Ticket No.: 22276 Slump(ASTM C-143): 3.75 Made By: ALPHA Air Content: 5.5 (ASTM C-173) Air Temperature: 77 Cured Specification: ASTM C-31 Specimen Temperature: 80 Date Received: 5/23/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: CASANOVA,STEVEN Mix Data Submitted By: SITE CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI: 41 LAB C-1231 5/29/01 7 12 N/A 6 28.27 92570 3270 42 LAB C-1231 6/19/01 28 12 N/A 6 28.27 133579 4720 43 LAB C-1231 6/19/01 28 12 N/A 6 28.27 127441 4500 44 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3600 `Results to Date: PASS I Notes: Respectfully Submitted By: 4U of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client(and their designated receplents on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed,and are not indicative of¢the qualities of apparently identical or similar specimens. g 3 /� y=y ��j�j� ...a 7Tra XE'i- 3 t1�tt110 .1 P ,x .7'T � F�,x on t 1'**nt "i Y 46410 0**4 4� i3I.- .-7,7*,'-`" 8F31�