Loading...
Townhouses-LR010709 REPORT OF FIELD Nk COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 07/09/01 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-169 COPPELL,TEXAS TEST DATA: RAISED ELEVATION ON THESE PADS TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT' % PCF % PCF 2136 07/09/01 FG+ 9 15.5 111 19.4 106 96 1-A 2137 07/09/01 FG+ 9 15.5 111 19.4 109 98 1-A 2138 07/09/01 FG+ 9 15.5 111 17.3 109 98 1-A 2139 07/09/01 FG+ 9 15.5 111 19.0 106 96 1-A 2140 07/09/01 FG+ 9 15.5 111 17.9 107 96 1-A 2141 07/09/01 FG+ 9 15.5 111 17.7 107 96 1-A 2142 07/09/01 FG+ 9 15.5 111 18.6 107 97 1-A TEST LOCATION: 2136 12'EAST AND 50'SOUTH FROM NORTHWEST CORNER OF BLOCK A, PAD#2 2137 12'EAST AND 50'SOUTH FROM NORTHWEST CORNER OF BLOCK A, PAD#3 2138 12'EAST AND 50'SOUTH FROM NORTHWEST CORNER OF BLOCK A, PAD#4 2139 12' EAST AND 50'SOUTH FROM NORTHWEST CORNER OF BLOCK A, PAD#5 2140 12'EAST AND 50'SOUTH FROM NORTHWEST CORNER OF BLOCK A, PAD#6 2141 12'EAST AND 50'SOUTH FROM NORTHWEST CORNER OF BLOCK A, PAD#7 2142 12'EAST AND 50'SOUTH FROM NORTHWEST CORNER OF BLOCK A, PAD#65 CC: STEVE TOPLTEZ,ANDANTE - GARRETH CAMPBELL, CITY OF COPPELL / 1. FILL *A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS R,-.-. Ily S y ed 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS I 4. CEMENT TREATED D. RETEST •LP • # NG,INC. Our test results&reports are for the exclusive use of the Client(and thek designated recipients on file In our office)and shall not be reproduced and/or d', -uted-cept express app. -I of ALPHA The use of our name&test results must receive our written approval. Test results&reports apply only to the samples tested and/or observed,and are not indicative of the qual'••s of apparently -entical or similar specimens. Geotechnical Engineering I Construction Materials Testing I Environmental Engineering I Consulting REPORT OF FIELD 1/ COMPACTION TESTS ALPHA TESTING, INC. • 2209 Wisconsin St.,Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 07/09/01 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-169A COPPELL,TEXAS TEST DATA: RAISED ELEVATION ON THESE PADS TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 2143 07/09/01 FG+ 9 15.5 111 19.3 106 96 1-A 2144 07/09/01 FG+ 9 15.5 111 19.3 107 96 1-A 2145 07/09/01 FG+ 9 15.5 111 18.3 107 96 1-A 2146 07/09/01 FG+ 9 15.5 111 19.3 106 95 1-A 2147 07/09/01 FG+ 9 15.5 111 19.5 106 95 1-A 2148 07/09/01 FG+ 9 15.5 111 19.5 106 96 1-A 2149 07/09/01 FG+ 9 15.5 111 19.1 106 95 1-A TEST LOCATION: . 2143 12'WEST AND 50' NORTH FROM SOUTHEAST CORNER OF BLOCK A, PAD#64 2144 12'WEST AND 50' NORTH FROM SOUTHEAST CORNER OF BLOCK A, PAD#63 2145 12'WEST AND 50'NORTH FROM SOUTHEAST CORNER OF BLOCK A, PAD#62 2146 12'WEST AND 50' NORTH FROM SOUTHEAST CORNER OF BLOCK A, PAD#61 2147 12'WEST AND 50' NORTH FROM SOUTHEAST CORNER OF BLOCK A, PAD#59 2148 12'WEST AND 50'NORTH FROM SOUTHEAST CORNER OF BLOCK A, PAD#58 2149 12'WEST AND 50' NORTH FROM SOUTHEAST CORNER OF BLOCK A, PAD#57 CC: STEVE TOPLTEZ,ANDANTE - GARRETH CAMPBELL, CITY OF COPPELL 1. FILL •A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS / / 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS pec . itted tted 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST ALPH, =T G,IN . Our test results&reports are for the exclusive use of the Client(and the designated recipients on file In our office)and shall not be reproduced and/or d':.'r uted e,.-pt . express a proval of ALPHA The use of our name&test results must receive our written approval. Test results&reports apply only to the samples tested and/or observed,and are not Indicative of the al' of apparen. identical or simXar specimens. Geotechnical Engineering I Construction Materials Testing I Environmental Engineering I Consulting