Townhouses-LR010719 REPORT OF FIELD
Niii, COMPACTION TESTS
ALPHA TESTING, INC.
2209 Wisconsin St,,Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263-4937(Metro)
FAX: 972/406-8023
TESTED FOR LEMP DEVELOPMENT DATE 07/19/01
DALLAS, TEXAS
PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-173 .
COPPELL, TEXAS
TEST DATA:
TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT*
% PCF % PCF
2181 07/19/01 FG 4 20.1 101.9 22.0 98 97 1-A
2182 07/19/01 FG 1 22.5 99.5 24.2 97 97 1-A
2183 07/19/01 FG 1 22.5 99.5 24.8 96 96 1-A
2184 07/19/01 FG-2.0 1 22.5 99.5 23.0 97 98 1-A
2185 07/19/01 FG-1.5 1 22.5 99.5 23.1 98 98 1-A
2186 07/19/01 FG-0.5 1 22.5 99.5 23.2 97 97 1-A
2187 07/19/01 FG 1 22.5 99.5 22.6 98 98 1-A
TEST LOCATION: FILL FOR RETAINING WALL
2181 12' N AND 15' E FROM SE CORNER OF BLOCK A, PAD 40
2182 12' N AND 15' E FROM SE CORNER OF BLOCK A, PAD 38
2183 12' N AND 15' E FROM SE CORNER OF BLOCK A, PAD 26
2184 10' N AND 10' E FROM SE CORNER OF BLOCK A, PAD 34
2185 10' N AND 10' E FROM SE CORNER OF BLOCK A, PAD 33
2186 10' N AND 10' E FROM SE CORNER OF BLOCK A, PAD 32
2187 10' N AND 10' E FROM SE CORNER OF BLOCK A, PAD 31
CC STEVE TOPLTEZ, ANDANTE - GARRETH CAMPBELL, CITY OF COPPELL
1 FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
2 NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Res.- ly Submitted
3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
4 CEMENT TREATED D. RETEST -- STING,INC.
Our test results&reports are for the exclusive use of the Client(and their designated recipients on file in our office)and shall not be reproduced and/or distributed except wi - press ap. . al of A A e use
of our name&test results must receive our written approval. Test results&reports apply only to the samples tested and/or observed,and are not indicative of the qualities of apparently identic or ar specimens
Geotechnical Engineering 7 Construction Materials Testing n'% Environmental Engineering I." Consulting
REPORT OF FIELD
// . COMPACTION TESTS
ALPHA TESTING, INC.
2209 Wisconsin St.,Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263-4937(Metro)
FAX: 972/406-8023
TESTED FOR LEMP DEVELOPMENT DATE 07/19/01
DALLAS, TEXAS
PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-173A
COPPELL, TEXAS
TEST DATA
TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT*
PCF % PCF
2188 07/19/01 FG 1 22.5 99.5 24.3 96 97 1-A
2189 07/19/01 FG-4.0 1 22.5 99.5 22.7 98 98 1-A
2190 07/19/01 FG-3.5 1 22.5 99.5 24.1 96 96 1-A
2191 07/19/01 FG-3.0 1 22.5 99.5 24.3 96 97 1-A
2192 07/19/01 FG-2.5 1 22.5 99.5 23.6 97 97 1-A
TEST LOCATION: RETAINING WALL FILL
2188 15' E AND 12' N FROM SE CORNER OF BLOCK A, PAD 34
2189 15' E AND 12' N FROM SE CORNER OF BLOCK A, PAD 27
2190 15' E AND 12' N FROM SE CORNER OF BLOCK A, PAD 28
2191 15' E AND 12' N FROM SE CORNER OF BLOCK A, PAD 27
2192 15' E AND 12' N FROM SE CORNER OF BLOCK A, PAD 28
CC STEVE TOPLTEZ, ANDANTE - GARRETH CAMPBELL, CITY OF COPPELL
F'LL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
2 NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Res•e r
3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
4 CEMENT TREATED D. RETEST ALPHA TESTING,INC.
lest'esults&reports are for the exclusive use of the Client(and their designated recipients on file in our office)and shall not be reproduced and/or distribute• ept with expre ••roval• •HA he use
r f ore name&test results must receive our written approval. Test results&reports apply only to the samples tested and/or observed,and are not indicative of the qualities• .._ ••-:entic- or similar.pecimens
Geotechnical Engineering i Construction Materials Testing /_%Environmental Engineering is Consulting
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 10 Concrete Compression Test
Dallas, Texas 75229 Report
(972) 620-8911
p
Tested For: LEMP DEVELOPMENT Our Report No.: 00430-162
ATTN: GREG LEMP Issue Date: 07/19/2001
4101 MCGWEN,SUITE 110
DALLAS,TX 75244
Fax Number: (972)404-1833
Project Desc: COPPELL TOWNHOMES
COPPELL,TEXAS
HELD DATA
Placement Location: MC 6-16 BOX CULVERT MIDDLE WALLS,STATION 4+00 TO 6+00
Date Placed: 6/20/01 Plant Number: 27-4500
Time Placed: 11:20 AM Delivery Ticket No.: 862856
Slump(ASTM C-143): 4.0 Made By: ALPHA
Air Content: N/A
Air Temperature: 85 Cured Specification: ASTM C-31
Specimen Temperature: 92
Date Received: 6/21/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: JOHNSTON,DARREL
Mix Data Submitted By: HANSON
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI:
97 LAB C-1231 6/27/01 7 12 N/A 6 28.27 115448 4080
98 LAB C-1231 7/18/01 28 12 N/A 6 28.27 163711 5790
99 LAB C-1231 7/18/01 28 12 N/A 6 28.27 167873 5930
100 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 4000
Results to Date: PASS
Notes:
Respectfully Submitted By: �/ of Alpha Testing,Inc.
Our test results and reports are for the exclusive use of the Client Kul their designated receplents on file in our office)and shall not be reproduced and/or distributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed,and are not Indicative of the qualities of apparently identical or similar specimens.