Loading...
Townhouses-LR010726 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 10 Concrete Compression Test Dallas, Texas 75229 Report (972) 620-8911 p Tested For: LEMP DEVELOPMENT Our Report No.: 00430-165 ATTN: GREG LEMP Issue Date: 07/26/2001 4101 MCGWEN, SUITE 110 DALLAS,TX 75244 Fax Number: (972)404-1833 Project Desc: COPPELL TOWNHOMES COPPELL,TEXAS FIELD DATA Placement Location: MC 6-16 BOX CULVERT TOP @ STATION 5+00 Date Placed: 6/26/01 Plant Number: 27-4500 Time Placed: 4:30 PM Delivery Ticket No.: 863175 Slump(ASTM C-143): 4.5 Made By: ALPHA Air Content: N/A Air Temperature: 92 Cured Specification: ASTM C-31 Specimen Temperature: 95 Date Received: 6/27/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: VICORS,VICTOR Mix Data Submitted By: HANSON CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI: 101 LAB C-1231 7/3/01 7 12 N/A 6 28.27 130200 4600 102 LAB C-1231 7/24/01 28 12 N/A 6 28.27 151032 5340 103 LAB C-1231 7/24/01 28 12 N/A 6 28.27 150804 5330 104 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 4000 Results to Date: PASS Notes: Respectfully Submitted By: �/,f�� of Alpha Testing,Inc. Our test results and reports are for the exclusive use of the Client(and their designated recepients on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed,and are not indicative of the qualities of apparently identical or similar specimens.