Loading...
Townhouses-LR010803 ALPHA TESTING, INC. Concrete Compression Test ���� 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 Report (972) 620-8911 p Tested For: LEMP DEVELOPMENT Our Report No.: 00430-174 ATTN: GREG LEMP Issue Date: 08/03/2001 4101 MCGWEN,SUITE 110 DALLAS,TX 75244 Fax Number: (972)404-1833 Project Desc: COPPELL TOWNHOMES COPPELL,TEXAS FIELD DATA Placement Location: CONCRETE EMBEDMENT DRAINAGE FLUME ALONG ENTIRE N.WALL Date Placed: 7/23/01 Plant Number: 7-5.0 SK Time Placed: 3:55 PM Delivery Ticket No.: 7105223 Slump(ASTM C-143): 3.5 Made By: ALPHA Air Content: 4.0 (ASTM C-173) Air Temperature: 100 Cured Specification: ASTM C-31 Specimen Temperature: 97 Date Received: 7/24/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: BROWN,REESE Mix Data Submitted By: LMC CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI: 105 LAB C-1231 7/30/01 7 12 N/A 6 28.27 86180 3040 106 LAB 8/20/01 28 12 N/A 6 28.27 0 107 LAB 8/20/01 28 12 N/A 6 28.27 0 108 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 4000 Results to Date: N/A Notes: Respectfully Submitted By: A V of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client(and their designated recepients on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed,and are not indicative of the qualities of apparently identical or similar specimens. Via» �, / e‘x��;� --.� .�•1z;`;')t�l�'-;.. ti: ,� ��.' � � � .��� �a ��_. ,h" .cv`,,4t*.�, �a:. rh