Big Cedar-CS 910829DRC DATE:
REVIEW OF:
CITY OF COPPELL
PUBLIC WORKS
ENGINEERING DIVISION
BY:
Shohre Daneshmand, Phone ~ 462-8495
PREL/.MINARY PLAT AND PLAMS:
Please make the following additions and/or corrections to 'the
preliminary plat, as marked:
The names and zoning of adjacent properties, n~mes on
record of owners of adjoining parcels.
2)
3)
The location, widths and names of all existing and
proposed streets, easemen'ts, fire lanes or other public
ways within or adjacent to the trac'l'-.
Existing and proposed zoning of. 'the site and the
surrounding properties.
4)
S)
- Topography of the site (intervals of 5 feet or less,
referred, to sea level datum).
Per Floodplain Manageh%ent Ordinance 41'~7390, (Ar-~'~ 5, Sec.
' C, Item 4, Page 34), all subdivision proposals must have
-the following note placed on the preliminary a~]d final
plats. '"
"Floodplain Development Permi't Application No.
has been filed with the City of Coppell Floodplain
Administrator on , 19 .
6)
1)
2)
(FlOodplain Administrator)
( Date )
- No Con~ent.
The following information, as marked, is required to be
c_~ained in the preliminary engineering plans.
Submit preliminary engineering plans.
The plans shall show existing structures, utilities,
sewers, water mains, culverts, power poles, telephone
Page 1/2
3)
4)
5)
6)
7)
9)
lines, gas lines, and other underground structures within
the tract and immediately adjacent thereto with pipe
sizes and locations. Provide dimension controls for all
utilities and right-of-ways.
On appropriate plans, provide a legend identifying the
utilities,' such as water, sewer, gas line, storm'sewer
...etc
Preliminary plans of proposed water dis'%ributio~ system
sewage collection system and their relation
~o't~e existing utilities in the'a~e~, and to the Utility
Master Plan.
Provide a Drainage Area Map, covering two parts:
a)
show On-site Drainage Map, on a scale of 1"-20'
-- ,
40', 50', etc. . . ; with all details as required in
tho Subdivision Ordinance.
show the Off-site Drainage Map, on. a~--scale 'of
1"=100', 200', etc' . Delineate. the project's
boundary on it, plus 't~e less detailed drainage
system, to clearly demonstrate the affect of such
activities, drainage outfalls, on the adjacent
properties and the Drainage Master Plan.
- If the applicant is requesting' any variance to the
Subdivision Ordinance, he/she must submit a letter
specifically outlining his respective requests. This
/~'letter shall be submitted along with corrected plan.
Show the boundaries of the 100-year Floodplain and
'Floodway clearly on the preliminary and final plats.
Ail above comments must be addressed, prior to staff's
. pDeCommendation for approval of the preliminary plat and
lane.
· Provide a written response on all comments, with
explanations provided on items not addressed as requested
above.
DRC/COM/4ENTS/ENG/PRELIM
Page 2/2