Loading...
Villas at LV 2-CS121127 DI-MIX CONCRETE) November 27,2012 Red-Mx Cofaete,L.P. a US Concrete Company To: Guzman Construction The Technical Service Department 331 North Main St Euless,TX 76039 Project: Villas at Lake Vista P- —Coppell Office:(817)835-4100 Fax(817)439-6701 RE: Submittal Provisions RedmixQC®usmtcrete.cam www.us-mocrete.00m Enclosed you will find the necessary submittal documents for the referenced project above for your review. Redi-Mix's strength guarantee per ASTM C94 will not be effective unless the field sampling has been done per ASTM C172 and ASTM C31 and the laboratory testing fully complies with ASTM C39 and ASTM C 1077.Redi-Mix will also guarantee the strength performance of the mix designs submitted for a concrete temperature between 55°F and 95°F provided the design plastic properties arc not exceeded and the concrete is placed within 90 minutes of batch time.This concrete temperature range shall not supersede any temperature specification.All concrete should be placed and cured with the appropriate ACI guidelines and recommendations for hot and cold weather concreting. Redi-Mix cannot be responsible for non-conformance of strength if cylinders are not cured per ACI 301,section 1.63.2.d. Hot weather concreting practices will require you to order ice and/or chilled water to meet concrete temperature specifications. The purchaser shall be responsible for precautions taken against excessive wind,heat and low humidity per AC1 305 guidelines. The purchaser shall assume responsibility for any concrete defects related to the finishing process (cracking, sealing, dusting, delamination, discoloration,etc.),which is beyond Redi-Mix's control.This includes proper preparation,compaction and wetting of subgrade as well as proper spacing and depth of joints and rebar. During periods of cold weather,all concrete surfaces should be protected from frying for at least the first 24 hours after placement to allow the concrete to attain a compressive strength of 500 psi. Should the purchaser elect not to order temperature control measures,the purchaser shall then assume all liability for costs associated with rejected concrete due to non-compliant concrete temperature. According to ACI 304.28 Section 42.1"Placing Concrete by Pumping Methods",the inside diameter of the hose should be a minimum of 3 times the maximum angular aggregate size of the concrete. (ASTM C33 allows#57LS to have up to 5% retained on the 1"sieve), It is recommended to minimize or eliminate the free fall of concrete to avoid loss of air content Depending on boom configurations,alterations to the mix design may be required.With regard to pumped concrete,the various boom configurations,length of hose,line reductions and free fall distance are beyond Redi-Mix's control and we therefore cannot be responsible for loss of air content or any costs associated with either rejected fresh concrete or the removal and replacement of hardened concrete due to non-compliant air content We thank you for allowing us to submit these documents for your review. Please copy Redi-Mix with the approved submittal. The approved submittal allows Redi-Mix to review any notes,comments or exceptions made by the engineer or owner relating to the specification. Failure to notify us prior to first placement shall constitute acceptance of the submitted mix designs and submittal provisions. Please order by mix number when scheduling concrete delivery. We request that you add Redi-Mix to the list of names receivirur suuies of testing laboratory information for this project. ASTM C94 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. This information is another tool for Redi-Mix to review and monitor the quality and performance of the concrete product delivered. The information within this submittal is confidential and the exclusive property of Redi-Mix. It shall not be disseminated to third parties without written permission from Redi-Mix Concrete. Please contact Technical Services with any questions at(817)835-4186. Respectfully, lizliyi2e1/1// Carol Dunn Technical Services Supervisor t w NEW E Frtk THE NSTRUCT $ ON i rvoclg LPL' CgNICRFTF £T/2'd OLS£b0£2LST:01 90T2-2L8-Ob6 'ONI `INIdN:WOZId 617:0T 2T02-82-(1ON DIIMIX Date: 11/27/2012 Ad. CONCRETE Mix Number: • -1-0' Redi-Mix Concrete, L.P. Strength: 000 p • , 28 d, a US Concrete Company Description: -. •K AIR NR The Technical Service Department 331 N.Main St Plant No.: 259 Euless,TX 76039 Customer: Guzman Construction Office:(817)8354187 Fax: (817)835-4074 Project: Villas at Lake Vista PH II - Coppell RedimixQC @usconcrete.com Usage: Inlet Structures www.us.concrete.com Saturated Surface Dry Weights Per Cubic Yard Material Source Quantity Vol ASTM C150 Type I/II Cement Cemex, Balcones 564 lb 2.87 0 0.00 ASTM C33 No. 57 LS Martin Marietta, Chico 1825 lb 11.21 ASTM C33 Concrete Sand Redi-Mix Concrete 1282 lb 7.84 ASTM C494 A & D NRWR BASF 322N 2-4 oz/cwt ASTM C260 Air Entrainment BASF AE90 1-4 oz/cy 1.08 ASTM C94 Water 30 gal 4.00 Total Volume: 27.00 Specified Slump 4 +/- 1" Specified Air Percent: 4.5 +/- 1.5% Wet Unit Weight: 145.2 Ib/ft^3 Design w/c ratio: 0.44 The use of an EF Technology mix design will reduce the amount of CO2 entering the atmosphere, thereby reducing potential global warming. "Your Project, Our World" Notes: Please make sure that redimixgc @us-concrete.com is on the list to receive break reports. (1/4 i, ii; z91 , This mix has been designed to meet the requir ents of this project based on the information sent to Redi-mix Concrete.It is the responsibility of the purchaser to determine whether this mix design meets project specifications and is appropriate for the anticipated environment conditions.The specified strength guarantee per ASTM C94 will not be effective unless field sampling has been done per ASTM C172 and ASTM C31 and the laboratory fully complies with ASTM C39 and ASTM C1077.In the event of limited material availability,substitution of a similar performing material may be required.All substituted materials will meet the appropriate ASTM requirements.In order to maintain the required mix volume,weights of individual materials may be varied to accommodate different material specific gravities.Material certifications for substituted materials are avaliable upon request. All Redi-Mix Concrete mix designs are proprietary and confidential.The information contained in this submittal is only intended for parties associated with this project to validate the mix design materials,properties and its performance.Use of this submittal for other purposes without permission or consent from Redi-Mix Concrete is strictly prohibited. awK^° T H E N E W R E S O U R C E F O R T H E C O N S T R U C T I O N I N D U S T R Y CONCRETE MIX 10L11504 ACI-318 Statistical Analysis MAX 93 81 5.00 3330 5275 6040 6100 1788 5.6 MIN 59 50 3.00 3130 3195 4650 5870 -319 3.0 NO. 15 14 15 2 15 15 2 15 15 MEAN 75 67 4.32 3230 4208 5050 5985 843 4.4 SD 9.0 8.0 0.60 141 533 406 163 483 0.9 COV% 12.0 11.9 13.9 4.4 12.7 8.0 2.7 57.3 21.2 DATE CONC AIR 3D 7D 28D 56D 7-28 Air % YY-MM-DD TEMP TEMP SLMP STR. STR. STR. STR. GAIN 2011-10-31 73 68 4.75 3840 5147 1307 4.3 2011-11-09 59 75 4.75 3130 4440 4740 6100 300 4.8 2011-12-22 70 50 3.50 4400 5840 5870 1440 4.6 2012-01-07 64 55 4.00 3195 4983 1788 3.3 2012-01-19 70 66 3.00 3795 4655 860 3.0 2012-01-31 72 64 4.00 3330 4180 5043 863 3.2 2012-03-07 75 64 5.00 5275 6040 765 4.0 2012-03-23 75 68 5.00 3665 4650 985 5.5 2012-03-27 79 59 4.00 3805 4787 982 4.0 2012-03-30 72 70 4.00 4255 5063 808 3.4 2012-04-13 81 66 4.00 4130 4913 783 4.0 2012-04-16 84 81 4.75 4151 4751 600 5.3 2012-04-16 81 73 4.25 4338 5171 833 5. 5 2012-04-16 84 4.75 4539 5181 642 5.5 2012-04-18 93 72 5.00 5111 4792 -319 5.6 PER ACI-318, TABLE 5.3.2.1 & 5.3.1.2 REQUIRED AVERAGE STRENGTH (F'CR)= 0.90 (F'C) + 2.335 (1.16) F'CR = 4597 AVERAGE MEAN FOR THIS MIX IS 5050 WHICH EXCEEDS THE OVER DESIGN Page 1 CC-MC-X wall Road CEMENT New Braunfels,TX 78132 Telephone(210)250-4100 MILL FAX(210)250-4044 Customer Service TEST TXDOT MPL#99332 Telephone(800)492-9004 REPORT Material#1442809 FAX(210)250-4153 Cement Identified as: Balcones Type I,Type II Low Alkali Date of Report:08/01/2012 Plant: CEMEX Cement of Texas, LP Beginning Production Date: July 1,2012 Location: New Braunfels,TX Ending Production Date: July 31,2012 CHEMICAL REQUIREMENTS 'Spec.Limit TYPE I TYPE II I TEST (ASTM C-114) (ASTM C-150) Low Alkali Low Alkali RESULTS Silicon Dioxide(Si02), % Min --- --- 20.2 Aluminum Oxide(AI203),% Max --- 6.0 4.6 Ferric Oxide(Fe203),% Max --- 6.0 3.4 Calcium Oxide(CaO),% - --- --- 64.8 Magnesium Oxide(MgO),% Max 6.0 6.0 1.0 Sulfur Trioxide(S03),% * Max 3.0 3.0 2.6 Loss on Ignition(LOI),% Max 3.0 3.0 2.2 Insoluble Residue(IR),% Max 0.75 0.75 0.16 Free Lime,% --- --- --- 1.5 Alkalies(Na20 equivalent),% Max 0.60 0.60 0.52 Na20 Equ.@ 95%Confidence Level -- --- --- 0.52+/-0.02 CO2 in Cement,% -- --- --- 1.3 Limestone in Cement,% Max 5.0 5.0 1.4 CaCO3 in Limestone,% Min 70 70 93 Inorganic Processing Addition,% ** Max 5.0 5.0 0.6 PONTENTIAL PHASE COMPOSITION*** I Tricalcium Silicate(C3S),% Max --- --- 60 Tricalcium Aluminate(C3A),% Max --- 8 6 Heat Index,C35+(4.75 C3A) Max 100 100 91 PHYSICAL REQUIREMENTS (ASTM C-204) Blaine Fineness,m2/kg Min 280 280 403 (ASTM C-191) Time of Setting (vicar) Initial Set, mins Min 45 45 109 Final Set, mins Max 375 375 203 (ASTM C-266) Time of Setting (Giumore) Initial Set, mins Min 60 60 168 Final Set, mins Max 600 600 229 (ASTM C-185) Air Content,% Max 12 12 8 (ASTM C-151) Autoclave Expansion, % Max 0.80 0.80 0.03 (ASTM C-109) Compressive Strength 1-Day, psi -- --- --- 2320 3-Day, psi Min 1740 1450 4090 7-Day, psi Min 2760 2470 5120 (Previous)28-Day, psi -- --- --- 6250 (ASTM C-186) Heat of Hydration(7-Day),cal/g Test result is provided for information only 79 The performance of CEMEX Type I LA, Type II LA has proven to be improved with sulfur trioxide levels in excess of the 3.0%limit for Type II. Note D in ASTM C-150 allows for additional sulfate,provided expansion as measured by ASTM C-1038 does not exceed 0.020%. ** This cement contains processing additions which meet the requirements of ASTM C-465.Compliance documents are available upon request. Additional data for the Inorganic Processing Addition is located on page 2 of this certification. **' Potential Phase Composition adjusted per A1.6. CEMEX hereby certifies that this cement meets or exceeds the chemical and physical specifications of: [X] ASTM C-150 for Type I Low Alkali - -.� [X] ASTM C-150 for Type II Low Alkali k��" -°-` Quality Control Manager CEMEX-Balcones Cement Plant 2580 Wald Road CEMENT New Braunfels,TX 78132 CCt11C Telephone(210)250-4100 MILL FAX(210)250-4044 Customer Service TEST Telephone(800)492-9004 REPORT FAX(210)250-4153 Cement Identified as: Balcones Type I,Type II Low Alkali Date of Report:08/01/2012 Plant: CEMEX Cement of Texas, LP Beginning Production Date: July 1,2012 Location: New Braunfels,TX Ending Production Date: July 31,2012 ADDITIONAL DATA Inorganic Processing Addition Type Lime Kiln Dust(LKDZ Silicon Dioxide(Si02),% 16.3 Aluminum Oxide(A1203),% 2.1 Ferric Oxide(Fe203), % 0.0 Calcium Oxide(CaO), % 79.7 Sulfur Trioxide(S03), % 13.2 Base Cement Phase Composition C3S,% 63 C2S, % 13 C3A,% 7 C4AF,% 11 CEMEX hereby certifies that the above described data represents the materials used in the cement manufactured during the production period indicated. By: Quality Control Manager CEMEX-Balcones Cement Plant "MIX . F CONCRETE CONCRETE 1 REDI-MIX TECHNICAL SERVICES LABORATORY SIEVE ANALYSIS RESULTS Plant: REDI-MIX CONCRETE, Plant 259 Product: Fine Aggregate, ASTM C33 Section 5 Date Sampled: 6/11/12 Date Tested: 8/2/12 Tested by: WCH Percentage SPEC'S Sieve mm %Ret %Pass - 11/2 38.10 0 100 - 1 25.40 0 100 3/4" 19.00 0 100 100 1/2" 12.70 0 100 100 3/8" 9.51 0 100 100 #4 4.76 1 99 95-100 #8 2.38 15 85 80-100 #16 1.19 34 66 50-85 #30 0.60 50 50 25-60 #50 0.30 74 26 05-30 #100 0.15 94 6 0-10 Pan 100 0 - #200(Decant) 0.07 - 2 0-3 FM 2.7 2.3-3.1 ABS% 1.8 S.G. 2.61 �i Technical Resource Supervisor Mirtin.#ti is ttaatatit is . wr . Detail Quality Statistical Summary Report • Period 07/01/2012-09/19/2012 Plant 54501-Chico Quarry Product 511-#57 Cone Agg Specification No.57 Concrete Aggregate Sieve/Test Tests Average Min Max Range St Dev Target Specification PWS 1 1/2"(37.5mm) 270 100.0 100.0 100.0 0.0 0.00 100-100 100-100 100.0 1"(25mm) 271 96.8 95.0 100.0 5.0 1.00 96-100 95-100 96.4 3/4"(19mm) 271 76.6 64.1 88.2 24.1 4.21 1/2'(12.5mm) 271 40.7 27.6 51.8 24.2 4A7 30-45 25-60 100.0 3/8"(9.5mm) 271 22.9 11,5 33.2 21.7 4.19 #4(4.75mm) 271 3.9 1.5 7.4 5.8 1.30 0-7 0-10 100.0 #8(2.36mm) 271 1.2 0.4 2.8 2.4 0.38 0-3 0-5 100.0 Pan 271 0.00 0.00 •0.00 0.00 0.000 4200(75um) • 92 0.56 0.20 0.80 0.60 0.161 <0.8 <1.5 100.0 Soundness(MgSO4) 1 11.9 11.9 11,9 0.0 <18 Micro-Deval 1 16.0 16.0 16.0 0.0 Absorption 2 1.54 1.47 1.60 0.13 0.092 SPGR(Dry,Gsb) 2 2.592 2.580 2.603 0.023 0.0163 SPGR(SSD) 2 2.631 2.621 2.641 0.020 0.0141 SPGR(Apparent,Gsa) 2 2.698 2.691 2.706 0.015 0.0106 Comments Query Query Selections Date Created 09/19/2012 Date Range 07/01/2012-09/19/2012 Plant Chico Quarry Sample Type Shipping r•'",,, Whitney D Gayter ex e,:, Notary Public 'p ' " State ofOklams * , CouatrOPPoatotee ` ' C o Daia# 69 Expiration Date October 16;2012 ,,,o r")//�c^ tif r t/t)hk(4)'" G) ? FG Co r1m issi a/ 40BOIOc �e 0,-1--,(0 t, (54- ac ■c, r aggQC 09/19/2012 Martin Marietta Materials,Inc. Page: 1 of 1 Wr#la Ailed tta Mataretsla Product Quality Summary Report Period 03/19/2012-09/19/2012 Plant 54501-Chico Quarry Product 511 #57 Conc Agg Specification No.57 Concrete Aggregate 1 1/2"(37.5mm) 100.0 1"(25mm) 96.7 • 3/4"(19mm) 75.4 1/2"(12.5mm) 39.9 3/8"(9.5mm) 23.1 #4(4.75mm) 4.5 #8(2.36mm) 1.3 Pan 0.00 -#200(75um) 0.61 LA Abrasion 26.9 Soundness(MgSO4) 13.4 Micro-Deval 18.9 Absorption 1.57 SPGR(Dry,Gsb) 2.587 SPGR(SSD) 2627 SPGR(Apparent,Gsa) 2.694 CaCO3 92.0 *lira D.G N ayle, otary Publk '1: State of Okliboran f,. County OfPoiatotot • Corantiasion#08010694 Expiration Date October 16 2912 4101°F-✓ bt)firAtt G M&rk. ()Iry►iSS of\ .1"O8Oi0(0 (4.7-410 dkc v■NcoN).-yer • aggQC i 09/19/2012 Martin Marietta Materials,inc. Page: 1 of 2 BASF The Chemical Company January 5, 2012 Certificate of Conformance Pozzolith 322N Admixture BASF Corporation*Admixture for Concrete *(successor in interest to BASF Construction Chemicals,LLC,which is successor by merger to BASF Admixtures, Inc., formerly known as Degussa Admixtures,inc.,formerly known as Master Builders,Inc.) TO WHOM IT MAY CONCERN: State of Ohio ) County of Cuyahoga ) SS Before me, a Notary Public, in and for the aforesaid State and County, personally appeared Richard Hubbard III, who being duly sworn, deposes and says: That he is a Sr. Technical Specialist for BASF Corporation in Cleveland, Ohio; and That Pozzolith 322N admixture is manufactured by BASF Corporation—Admixture Systems; and That Pozzolith 322N admixture, based on the chlorides originating from all the ingredients used in its manufacture, contributes less than 0.00024 percent (2.4 ppm) chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg (1 fluid ounce per 100 pounds) of cement; and That Pozzolith 322N admixture meets the requirements for a Type A, Water-Reducing, Type B, Retarding, and Type D, Water-Reducing and Retarding Admixture specified in ASTM C 494/C 494M, Standard Specifications for Chemical Admixtures for Concrete, as well as the requirements for Type A, Type B and Type D admixtures as specified in Corps of Engineers'CRD-C 87 and AASHTO M194. CN\ A—AA,b(JoiN.1 tr Richard Hubbard Ill BASF Corporation -Admixture Systems Subscribed and sworn to before me thP] 'jfL',day of Janua ,2012' f /- ( ff / Charlene R. Mandan' Notary Public,State of Ohio My Commission Expires November 4,2016 Recorded in Summit County Master Builders ,,,,, ,,., ,,,, '':'.:,,,:;':, - BASF The Chemical Company January 5, 2012 Certificate of Conformance Pozzolith 300R Admixture BASF Construction Chemicals *Admixture for Concrete *(successor in interest to BASF Construction Chemicals,LLC,which is successor by merger to BASF Admixtures,Inc., formerly known as Degussa Admixtures,Inc.,formerly known as Master Builders,Inc.) TO WHOM IT MAY CONCERN: State of Ohio ) County of Cuyahoga ) Ss Before me, a Notary Public, in and for the aforesaid State and County, personally appeared Richard Hubbard III, who being duly sworn, deposes and says: That he is a Technical Specialist for BASF Corporation in Cleveland, Ohio; and That Pozzolith 300R admixture is manufactured by BASF Corporation—Admixture Systems; and That no calcium chloride or chloride based ingredient is used in the manufacture of Pozzolith 300R admixture; and That Pozzolith 300R admixture, based on the chlorides originating from all the ingredients used in its manufacture, contributes less than 0.0002 percent (2.0 ppm) chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg (1 fluid ounce per 100 pounds)of cement; and That Pozzolith 300R admixture meets the requirements for a Type B, Retarding, and Type D, Water- Reducing and Retarding Admixture specified in ASTM C 494/C 494M, Standard Specifications for Chemical Admixtures for Concrete, as well as the requirements for Type B and Type D admixtures as specified in Corps of Engineers'CRD-C 87, and AASHTO M194. .'„,_-._\,...0,A._ .\\----„A, Tr_.1,\VT-CIT Richard Hubbard III BASF Corporation—Admixture Systems Subscribed and sworn to before me the 5 day of January, 20/2 Charlene R. Mandate Notary Public, State of Ohio My Commission Expires November 4,2016 Recorded in summit County Master Builders P„ BASF The Chemical Company January 5, 2012 Certificate of Conformance PolyHeed 1020 Admixture BASF Corporation*Admixture for Concrete '(successor in interest to BASF Construction Chemicals,LLC,which is successor by merger to BASF Admixtures,Inc., formerly known as Degussa Admixtures, Inc.,formerly known as Master Builders,Inc.) TO WHOM IT MAY CONCERN: State of Ohio ) County of Cuyahoga )ss Before me, a Notary Public, in and for the aforesaid State and County, personally appeared Richard Hubbard III, who being duly sworn, deposes and says: That he is a Sr. Technical Specialist for BASF Corporation in Cleveland, Ohio; and That PolyHeed 1020 admixture is manufactured by BASF Corporation—Admixture Systems; and That no calcium chloride or chloride based ingredient is used in the manufacture of PolyHeed 1020 admixture; and That PolyHeed 1020 admixture, based on the chlorides originating from all the ingredients used in its manufacture, contributes less than 0.00014 percent(1.4 ppm)chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg (1 fluid ounce per 100 pounds) of cement; and That PolyHeed 1020 admixture meets the requirements for a Type A, Water-Reducing, and Type F, Water-Reducing, High Range Admixture specified in ASTM C 494/C 494M, Standard Specifications for Chemical Admixtures for Concrete, as well as the requirements for Type A and Type F admixtures as specified in Corps of Engineers' CRD-C 87 and AASHTO M194. Richard Hubbard III BASF Corporation —Admixture Systems Subscribed and sworn to before me the th day of January, *12 ;r Charlene R.Mandat Notary Public,State of Ohio My Commission Expires November 4,2016 Recorded in summit County Master Builders BASF The Chemical Company January 5, 2012 Certificate of Conformance MB AE 90 Admixture BASF Corporation*Admixture for Concrete *(successor in interest to BASF Construction Chemicals,LLC,which is successor by merger to BASF Admixtures,Inc., formerly known as Degussa Admixtures,Inc.,formerly known as Master Builders,Inc.) TO WHOM IT MAY CONCERN: State of Ohio ) County of Cuyahoga )SS Before me, a Notary Public, in and for the aforesaid State and County, personally appeared Richard Hubbard III, who being duly sworn, deposes and says: That he is a Sr. Technical Specialist for BASF Corporation in Cleveland, Ohio; and That MB AE 90 admixture is manufactured by BASF Corporation—Admixture Systems; and That MB AE 90 admxiture is Master Builders air-entraining admixture for concrete; and That no calcium chloride or chloride based ingredient is used in the manufacture of MB AE 90admxiture; and That MB AE 90 admixture, based on the chlorides originating from all the ingredients used in its manufacture, contributes less than 0.000068 percent (0.68 ppm) chloride ions by weight of the cement when used at the rate of 65 ml. per 100 kg (1 fluid ounce per 100 pounds) of cement; and That MB AE 90 admixture meets the requirements of ASTM C 260, Standard Specifications for Air- Entraining Admixtures for Concrete, as well as the requirements for air-entraining admixtures as specified in Corps of Engineers CRD-C 13, and AASHTO M154. \r\ Richard Hubbard Ill BASF Corporation—Admixture Systems Subscribed and sworn to before me thzeirtli day of January, 12 Charlene R. Mandat Notary Public, State of Ohio My Commission Expires November 4,2016 Recorded in Summit County Master • Builders