Loading...
Tax 2011B-LR121210RLLU9hICE GErJTECHIYICRL W P _ Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 12/05/2012 Report Date: 12/10/2012 Sampled By: Jones, Richard Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: Van Blabber Drive Order Number: 1770 Client: City of Coppell REPORT: Nuclear Field Density Test LAB NO: 139472 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 139472 Page 1 of 1 Optimum Maximum Proctor Moisture Dry Density Proctor No Date (%) (pcf) Color/ Description 138912 -1 11/27/2012 23.9 96.0 Lime Treated Brown Clay 138912 -2 11/27/2012 31.0 87.3 Lime Treated Gray Clay Specification Moisture Band Specification No. Moisture Specification Compaction % Minimum Maximum 1 Opt + 1 95% 0.0 Material: Wet Moisture Dry Percent Test Lift # / Density Content Density Proctor Spec. Moisture Proctor Pass No. Depth Location (pcf) % (pcf) Number No. Deviation Density Fail 1 Final W.bound Van Bebber Dr, sta 17 +66 107.7 22.3 88.1 138912 -2 1 -8.7 100.9 Fail 2 Final W.bound Van Bebber Dr, sta 20 +60 110.9 21.5 91.3 138912 -1 1 -2.4 95.1 Fail 3 Final W.bound Van Bebber Dr, sta 22 +50 112.9 18.6 95.2 138912 -1 1 -5.3 99.2 Fail Gauge No.: 4563 Daily Standard Counts: 12/05/2012 DS: 2962 MS: 486 Test Methods: ASTM D6938 -07 Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. DOES NOT CONFORM Respectfully Submitted, Alliance Geotechnical Group t!� Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. I Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 12/07/2012 Report Date: 12/10/2012 Sampled By: Sarmiento, Alex Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: Van Bebber Drive Order Number: 1770 Client: City of Coppell REPORT: Nuclear Field Density Test LAB NO: 139662 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 139662 Page 1 of 1 Optimum Proctor Moisture Proctor No Date (%) 138912 -2 11/27/2012 31.0 Maximum Dry Density (pcf) Color / Description 87.3 Lime Treated Gray Clay Specification Moisture Band Specification No. Moisture Specification Compaction, % Minimum Maximum 1 Opt + 0.0 95.0 Material: Wet Moisture Dry Percent Test Lift # / Density Content Density Proctor Spec. Moisture Proctor Pass No. Depth Location (pcf) % (pcf) Number No. Deviation Density Fail 1 Grade Retest of test #1, dated 12/5/12 115.6 28.3 90.1 138912 -2 1 -2.7 103.2 Fail 2 Grade Retest of test #2, dated 12/5/12 119.1 29.7 91.8 138912 -2 1 -1.3 105.2 Fail Gauge No.: 17768 Daily Standard Counts: 12/07/2012 DS: 254 MS: 541 Test Methods: ASTM D6938 -07 Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. DOES NOT CONFORM Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.