Villas at LV 2-LR121027 From: 12/12/2012 15:33 #235 P.030/051
ALPHA / TESTING REPORT OF FIELD
2209 Wisconsin Street,Suite 100
COMPACTION TESTS
Dallas,Texas 75229
Geotechnical I Construction Materials I Environmental
www.alphatesting.com
TBPE Firm No.813
■
TESTED FOR: JBGL BF Development LLC DATE: 10/27/12
Dallas, Texas
PROJECT: Villas at Lake Vista Phase II -Site Grading OUR REPORT NO.: 1 21 535-1 9
Coppell, Texas
TEST DATA: TECHNICIAN: J. Ranjbaran
OPTIMUM MAXIMUM LAB IN PLACE IN PLACE
TEST ELEV. SOIL ID PERCENT
DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT'
NO. DEPTH NUMBER % PCF PCF COMPACTION
186 10/27/12 FG-1.5 3 21.2 98.3 28.4 92 3 1-A
187 10/27/12 FG-1.5 3 21.2 98.3 29.4 94 /96 1-A
188 10/27/12 FG-1.0 3 21.2 98.3 28.1 93 5 1-A
189 10/27/12 FG-1.0 3 21.2 98.3 28.9 93 94 1-A
190 10/27/12 FG-1.5 3 21.2 98.3 27.6 94 96 1-A
191 10/27/12 FG-1.5 3 21.2 98.3 29.1 95 97 1-A
192 10/27/12 FG-1.5 3 21.2 98.3 29,6 93 \\95 1-A
TEST LOCATION: Building Pad
186 40' N and 20'W from SE Corner of Block A, Pad 39
187 20' N and 60'W from SE Corner of Block A, Pad 40
188 60' N and 40'W from SE Corner of Block A, Pad 39
189 30' N and 50' W from SE Corner of Block A, Pad 40
190 50' N and 30'W from SE Corner of Block D, Pad 11
191 40'N and 20'W from SE Corner of Block D, Pad 12
192 20'N and 50'W from SE Corner of Block D, Pad 13
1. FILL "A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted,
4. CEMENT TREATED D. RETEST
*Ill14/17)
Bulent Ethem,P.G.
ALPHA TESTING,INC.
Our teat results and repats are for the exclusive use of the Client(and their designated recipients on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The
use of our name and led results must receive our written approval.Test results and reports apply only to the samples tested and/or observed,and are not Indoafba of the/pralities of apparently identical or similar
specimens.
From: 12/12/2012 15:34 #235 P.031/051
ALPHA / TESTING REPORT OF FIELD
2209 Wisconsin Street, Suite 100
COMPACTION TESTS
Dallas,Texas 75229
Geotechnical I Construction Materials I Environmental
www.alphatesting.com
TBPE Firm No.813
TESTED FOR: JBGL BF Development LLC DATE: 10/27/12
Dallas, Texas
PROJECT: Villas at Lake Vista Phase II -Site Grading OUR REPORT NO.: 121535-19A
Coppell, Texas
TEST DATA: TECHNICIAN: J. Ranjbaran
OPTIMUM MAXIMUM LAB IN PLACE IN PLACE
TEST ELEV. SOIL ID PERCENT
DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT*
NO. DEPTH NUMBER % PCF ro PCF COMPACTION
193 10/27/12 FG-1.5 3 21.2 98.3 27.7 94 96 1-A
194 10/27/12 FG-1.5 3 21.2 98.3 27.1 95 97 1-A
195 10/27/12 FG-1.0 3 21.2 98.3 29.4 94 96 1-A
196 10/27/12 FG-1.0 3 21,2 98.3 29.8 93 95 1-A
197 10/27/12 FG-1.0 3 21.2 98.3 27.9 92 94 1-A
198 10/27/12 FG-1.0 3 21.2 98.3 27.9 94 96 1-A
199 10/27/12 FG-1.0 3 21.2 98.3 27.7 93 95 1-A
TEST LOCATION: Building Pad
193 30'S and 30'W from NE Corner of Block D, Pad 14
194 20' S and 20'W from NE Corner of Block D, Pad 15
195 60' S and 50'W from NE Corner of Block D, Pad 11
196 40'S and 60'W from NE Corner of Block D, Pad 12
197 50'S and 30'W from NE Corner of Block D, Pad 13
198 30'S and 50'W from NE Corner of Block D, Pad 14
199 40'S and 20'W from NE Corner of Block D, Pad 15
1. FILL `A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted,
4. CEMENT TREATED D. RETEST
S-/1511-1144/1")
Bulent Ethem,P.G.
ALPHA TESTING,INC.
Our test results and reports are for the exclusive use of the Client(and their designated recipients on file In our office)and shell not be reproduced and/or dislrloted except with express approval of ALPHA.The
use of our name end test results must receive our written approval.Test results and reports apply only to the samples lasted and/or observed,and are not Indicative of the qualities of apparently Identical or simier
specimens.
From: 12/12/2012 15:34 #235 P.032/051
ALPHA +\ TESTING REPORT OF FIELD
2209 Wisconsin Street,Suite 100
COMPACTION TESTS
Dallas,Texas 75229
Geotechnical I Construction Materials I Environmental
www.alphatesting.com
TBPE Firm No.813
TESTED FOR: JBGL BF Development LLC DATE: 10/27/12
Dallas, Texas
PROJECT: Villas at Lake Vista Phase II -Site Grading OUR REPORT NO.: 121535-19B
Coppell, Texas
TEST DATA: TECHNICIAN: J. Ranjbaran
OPTIMUM MAXIMUM LAB IN PLACE IN PLACE
TEST ELEV. SOIL ID PERCENT
DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT'
NO. DEPTH NUMBER PCF % PCF COMPACTION
200 10/27/12 SG 3 21.2 98.3 24.8 94 96 2-A
201 10/27/12 FG-1.0 3 21.2 98.3 25.8 93 95 1-A
202 10/27/12 FG-0.5 3 21.2 98.3 24.7 94 96 1-A
203 10/27/12 FG 3 21.2 98.3 23.9 96 97 1-A
204 10/27/12 SG 3 21.2 98.3 24.8 95 96 2-A
205 10/27/12 SG 3 21.2 98.3 24.0 95 97 2-A
206 10/27/12 SG 3 21.2 98.3 25.6 94 96 2-A
TEST LOCATION: Building Pad
200 30'N and 30' E from SW Corner of Block A, Pad 41
201 40' N and 60' E from SW Corner of Block A, Pad 41
202 20' N and 30' E from SW Corner of Block A, Pad 41
203 60' N and 20' E from SW Corner of Block A, Pad 41
204 50'N and 50' E from SW Corner of Block A, Pad 42
205 20' N and 40' E from SW Corner of Block A, Pad 43
206 30' N and 50' E from SW Corner of Block A, Pad 44
1. FILL •A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted,
4. CEMENT TREATED D. RETEST
Bulent Ethem,P.G.
ALPHA TESTING,INC.
Our tort reaufte end reporter are for the exclusive use of the Client lend their designated redpienta on file in our office)and shall not be reproduced and(oe distributed except with express approval of ALPHA The
use of our name and teal results must receive our wiiten approval. Test results and reports apply only to the samples tested and/or observed.and are not indicative of the qualities of apparently identical or simtler
specimens.