Loading...
Villas at LV 2-LR121025 From: 12/12/2012 15:32 #235 P.024/051 ALPHA +\JTESTINC • REPORT OF FIELD 2209 Wisconsin Street,Suite 100 COMPACTION TESTS Dallas,Texas 75229 Geotechnical!Construction Materials I Environmental www.alphatesting.com TBPE Firm No.813 TESTED FOR: JBGL BF Development LLC DATE: 10/25/12 Dallas, Texas PROJECT: Villas at Lake Vista Phase II -Site Grading OUR REPORT NO.: 121535-16 Coppell, Texas TEST DATA: TECHNICIAN: J. Ranjbaran TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT" % PCF % PCF 145 10/25/12 SG 3 21.2 98.3 28.1 94 96 2-A 146 10/25/12 SG 3 21.2 98.3 27.6 93 95 2-A 147 10/25/12 SG 3 21.2 98.3 28.7 95 97 2-A 148 10/25/12 FG-4.5 3 21.2 98.3 30.2 92 93 1-A 149 10/25/12 FG-4.5 3 21.2 98.3 27.9 92 94 1-A 150 10/25/12 FG-4.5 3 21.2 98.3 27.3 94 96 1-A 151 10/25/12 FG-4.0 3 21.2 98.3 29.3 92 94 1-A TEST LOCATION: Building Pad 145 40'N and 30'W from SE Corner of Block A, Pad 36 146 20' N and 40'W from SE Corner of Block A, Pad 37 147 60' N and 20' W from SE Corner of Block A, Pad 38 148 50' N and 60'W from SE Corner of Block A, Pad 36 149 30' N and 40'W from SE Corner of Block A, Pad 37 150 40'N and 20'W from SE Corner of Block A, Pad 38 • 151 30' N and 50'W from SE Corner of Block A, Pad 36 1. FILL •A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST 51911141 Bulent Ethem,P.G. ALPHA TESTING,INC. Our test results and reports are for the exclusive use of the Orient land their deslgneted recipients on file in our office)and shall not be reproduced and/or dtslributed except with sucrose approve/of ALPHA. The use of our name end test resufs must reoaive our written approval.Test results and reports apply only to the samples tested end/or observed.end are not indicative of the qualities of apparently identical or sioler Spadmena. From: 12/12/2012 15:32 #235 P.025/051 ALPHA ATESTING REPORT OF FIELD 2209 Wisconsin Street, Suite 100 COMPACTION TESTS Dallas,Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No.813 TESTED FOR: - JBGL BF Development LLC DATE: 10/25/12 Dallas, Texas PROJECT: Villas at Lake Vista Phase II-Site Grading OUR REPORT NO.: 121535-16A Coppell, Texas TEST DATA: TECHNICIAN: J. Ranjbaran OPTIMUM MAXIMUM LAB IN PLACE IN PLACE TEST ELEV. SOIL ID PERCENT DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT* NO. DEPTH NUMBER % PCF % PCF COMPACTION 152 10/25/12 FG-4.0 3 21.2 98.3 28.0 95 96 1-A 153 10/25/12 FG-4.0 3 21.2 98.3 27.7 93 94 1-A 154 10/25/12 FG-3.5 3 21.2 98.3 29.6 92 93 1-A 155 10/25/12 FG-3.5 3 21.2 98.3 29.5 93 95 1-A 156 10/25/12 FG-3.5 3 21.2 98.3 27.8 93 94 1-A 157 10/25/12 FG-3.0 3 21.2 98.3 28.1 93 , 95 1-A 158 10/25/12 FG-3.0 3 21.2 98.3 30.6 92 93 1-A TEST LOCATION: Building Pad 152 20' N and 30' E from SW Corner of Block A, Pad 37 153 40' N and 40' E from SW Corner of Block A, Pad 38 154 30' N and 60' E from SW Corner of Block A, Pad 36 155 20' N and 50' E from SW Corner of Block A, Pad 37 156 25' N and 20' E from SW Corner of Block A, Pad 38 157 45' N and 30' E from SW Corner of Block A, Pad 36 158 60'N and 40' E from SW Corner of Block A, Pad 37 I. FILL •A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST 594/141 Bulent Ethem,P.G. ALPHA TESTING,INC. Our lest remelts and reports are for the eidusive use of the Client(end their designated recipients on file In our office)and shall not be reproduced mdlor dtstdbuled except with express approval of ALPHA.The use of our name and tad results must receiya our written approveL Toot results end reports apply only to the semples tested and/or observed.and are not indicative of the quallties of apparently identical or sender specimens. From: 12/12/2012 15:33 #235 P.026/051 ALPHA 4\ TESTING REPORT OF FIELD 2209 Wisconsin Street,Suite 100 COMPACTION TESTS Dallas,Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No.813 TESTED FOR: JBGL BF Development LLC DATE: 10/25/12 Dallas, Texas PROJECT: Villas at Lake Vista Phase II -Site Grading OUR REPORT NO.: 121535-16B Coppell, Texas TEST DATA: TECHNICIAN: J, Ranjbaran OPTIMUM MAXIMUM LAB IN PLACE IN PLACE TEST ELEV. SOIL ID PERCENT DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT` NO. DEPTH NUMBER % PCF k PCF COMPACTION 159 10/25/12 FG-3.0 3 21.2 98.3 27.5 95 97 1-A 160 10/25/12 FG-2.5 3 21.2 98.3 29.2 93 95 1-A 161 10/25/12 FG-2.5 3 21.2 98.3 28.1 94 96 1-A 162 10/25/12 FG-2.5 3 21.2 98.3 30.2 92 93 1-A 163 10/25/12 FG-2.0 3 21.2 98.3 30.4 92 94 1-A 164 10/25/12 FG-2.0 3 21.2 98.3 28.4 92 93 1-A 165 10/25/12 FG-2.0 3 21.2 98.3 28.6 93 95 1-A TEST LOCATION: Building Pad 159 30' S and 30'W from NE Corner of Block A, Pad 38 160 20'S and 40'W from NE Corner of Block A, Pad 36 161 50'S and 20'W from NE Corner of Block A, Pad 37 162 25'S and 50'W from NE Corner of Block A, Pad 38 163 45'S and 60'W from NE Corner of Block A, Pad 36 164 60'S and 30'W from NE Corner of Block A, Pad 37 165 30'S and 50'W from NE Corner of Block A, Pad 38 1. FILL •A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Bulent Ethem,P.G. ALPHA TESTING,INC. Our test results and reports we for the exclusive ties of the Client(and their designated recipients on file in our office)and shall not be reproduced andlor dlstrlbulad except with express approve/of ALPHA.The use of our name and test results must receive our written approval not results and reports apply only to the samples tested eMlor observed,and are not indicative of the qualities of apparently identical or similar Specimens.