Loading...
Chaucer-CS 920605 ,Coppell, Texas 75019  The City With A Beautiful Future 214-462-0022 June 5, 1992 Mr. Bill Anderson Dan M. Dowdey & Associates 16250 Dallas Parkway, Su!te iQ0 Dallas, IX 75248-2684 Re: Chaucer Estates Dear ~r. Anderson: ihe City of Coppeii has received and rev!ewed the referenced plans and has the fo!iowlng comments to offer: !he typical street section on Plate #2 shows the 4 foot sidewalk adjacent to the back of curb. Please be advised that any sidewalk adjacent to the back of curve should be 5 foot in width. However, our subdivision rules require that the s~dewa!k be placed i foot off the property line. Also, as per the subdivision rules, the sidewalk should be shown in the plan view and a note should be provided as to the schedule when the sidewalks will be installed. A vertical curve should be provided between Station 6 + O0 and 8 * 00 on Dickens Drive. Additional informatien should be provided concerning the slopes between Alley A and Heartz Road. There appears to be approximately a 4 !/2 foot difference in grade. 4 The drainage areas for the on-site drainage basins are very unusuai. Please reevaluate to ensure that this is the pattern that the lots will be graded by. 5) Profiles should be provided for all laterals and pipes. 6) Xore detaiis should be provided for the proposed wye inlet adjacent to Lot 2 Block C, i.e. the ditch section and the existing ground should be provided. 7} The inlets at Station 6 + 03 on Dickens Drive should be relocated further south. The street capacity on Dickens Drive is only approximately 15 CFS. 8) As we discussed on June 4, 1992, I have some concern about the hydraulics of the system. In several locations the hydraulic grade line of the 100-year storm is above the top of pavement. This occurs on both systems leaving the proposed lake area. Please reevaluate and comment on this situation. Letter to Mr. Mike Daniel, P.E. June 5, 1992 Page 2 9) The proposed 9 by 5 reinforced box culvert is entirely submerged in water at all times. It is my opinion that this pipe will experience siltation over time and could become a problem. Please comment how you intend to address this problem. Also, at the Development Review Committee meeting we were notified that the normal pool elevation for the lake will be raised to 459.5. Please comment as to how this will affect your drainage design. The service connections for the water line along Dickens Drive should be shown. 1!) As we previously discussed, a sewer line should be stubbed out for the property to the west. It appears that the stub should be between lots 21 and 22 of Block C. 12) A material list for the waterline at the intersection of Tennyson Place and Park Valley Drive should be provided. 13) Note 25 of the general notes should also state that the maximum cover of the sewer service is 6 foot. 14) The proposed manhole at Station 1 + 53.2 of Line A and Station 0 + 00 Line B is shown in one place as a drop manhole and not as a drop manhole in another place. These should be consistent. i5) The slope on the sewer line for Line A exceeds the maximum allowable slope. Please reevaluate. 16} The proposed drop manhole should have concrete encasement as per our standard details. 17) All inlets should be shown on the site grading plan. i8) Notice the locations that the site grading plans and the drainage area maps are inconsistent. These two documents should be consistent. 19) Please reevaluate the flow arrows shown on Lots 21 and 22 Block B. There are various other minor comments throughout these plans. Once all comments have been addressed, the revised set of plans should be resubmitted to the City for review. If you should have any questions concerning these comments, please feel free to contact me at your convenience. Sincerely, Kenneth M. Griffin, P.E. City Engineer k'MG/bd CHAUC