Tax 2011B-LR130104iiLLIf�YCE GEOTCCHfIICRL C�iOUP Consulting Engineering' Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 12/07/2012 Report Date: 01/04/2013 Previously Reported: 12/17/2012 Sampled By: Vidak, Neil Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: conc 250 paving Order Number: 1770 Client: City of Coppell REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 139605 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 139605 Page 1 of 3 Set: 1 of 3 Material: CONCRETE Location: W.bound Van Bebber Dr, station 11 +00 Number of Specimens: 4 C 01/04/13: 28 6.00 28.27 164,425 Type 2 Lab 5,820 D 01/04/13: 28 6.00 28.27 158,720 Type 2 Lab 5,610 F LI S t~ 111 R [_....._J [I Type 1 Type 2 Type 3 Type 4 Type 5 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 12/08/2012 Curing Method: Standard Maximum 10:15 am Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 12/10/12 :3 6.00 28.27 127,430 Type 2 Lab 4,510 4,510 B 12/14/12: 7 6.00 28.27 131,025 Type 2 Lab 4,630 4,630 C 01/04/13: 28 6.00 28.27 164,425 Type 2 Lab 5,820 D 01/04/13: 28 6.00 28.27 158,720 Type 2 Lab 5,610 F LI S t~ 111 R [_....._J [I Type 1 Type 2 Type 3 Type 4 Type 5 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 12/08/2012 Curing Method: Standard Time Sampled: 10:15 am Time Batched: 9:34 am Temp.: Ambient: 64 °F Mix: 70 °F CONFORMS Slump: 2.25 Inches Air Content: 5.7% Mix Code: 8274 5,710 LJ Type 6 Transported By: TXI Source /Sampled At: Truck / Center Plant: TXI - Plant #131 Truck /Ticket No: 1588 / 1559284 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 250 cu. yd. total placement Remarks: *Slump does not meet specifications Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. flU.Ifl�ICE GEOTECHNICML GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 12/07/2012 Report Date: 01/04/2013 Previously Reported: 12/17/2012 Sampled By: Vidak, Neil Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: conc 250 paving Order Number: 1770 Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 139605 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 139605 Page 2 of 3 Set: 2 of 3 Material: CONCRETE Location: W.bound lane of Van Bebber Dr, 5'W. of sta 13 +31 Number of Specimens: 4 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 12/08/2012 Curing Method: Standard Time Sampled: 12:35 pm Time Batched: 12:01 pm Temp.: Ambient: 68 °F Mix: 74 °F CONFORMS Slump: 3.0 Inches Transported By: TXI Air Content: 4.1% Source /Sampled At: Truck / Center Mix Code: 8274 Plant: TXI - Plant #141 Truck /Ticket No: 8025 / 1559611 Quantity Represented: 10 cu. yds. at 110 cu. yds. placed of a 250 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENTAN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTANDARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in Z) (lbs) Break Type Loc (PSI) (PSI) By Comments A 12/10/12: 3 6.00 28.27 98,065 Type 2 Lab 3,470 3,470 B 12/14/12:7 6.00 28.27 117,640 Type Lab 4,160 4,160 C 01/04/13 : 28 6.00 28.27 168,335 Type 2 Lab 5,950 D 01/04/13: 28 6.00 28.27 163,580 Type 2 Lab 5,870 15,790 El F1 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 12/08/2012 Curing Method: Standard Time Sampled: 12:35 pm Time Batched: 12:01 pm Temp.: Ambient: 68 °F Mix: 74 °F CONFORMS Slump: 3.0 Inches Transported By: TXI Air Content: 4.1% Source /Sampled At: Truck / Center Mix Code: 8274 Plant: TXI - Plant #141 Truck /Ticket No: 8025 / 1559611 Quantity Represented: 10 cu. yds. at 110 cu. yds. placed of a 250 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENTAN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTANDARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. ALLinnce GEOTKFiI'llCfil. CROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 12/07/2012 Report Date: 01/04/2013 Previously Reported: 12/17/2012 Sampled By: Vidak, Neil Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: cone 250 paving Order Number: 1770 Client: City of Coppell REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 139605 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 139605 Page 3 of 3 Set: 3 of 3 Material: CONCRETE Location: W.bound Van Bebber Dr, station 16 +00 Number of Specimens: 4 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 12/08/2012 Curing Method: Standard Maximum 3:25 pm Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 12/10/12 :3 6.00 28.27 103,175 Type 2 Lab 3,650 3,650 B 12/14/12: 7 6.00 28.27 130,135 Type 3 Lab 4,600 4,600 C 01/04/13: 28 6.00 28.27 161,835 Type 2 Lab 5,720 D 01/04/13 : 28 6.00 28.27_162,720 Type 2 Lab 5,760 5,740 E 11`71EI 11 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 12/08/2012 Curing Method: Standard Time Sampled: 3:25 pm Time Batched: 3:00 pm Temp.: Ambient: 73 °F Mix: 77 °F CONFORMS Slump: 2.5 Inches Transported By: TXI Air Content: 4.5% Source /Sampled At: Truck / Center Mix Code: 8274 Plant: TXI - Plant #141 Truck /Ticket No: 3804 / 1559942 Quantity Represented: 10 cu. yds. at 210 cu. yds. placed of a 250 cu. yd. total placement Remarks: *Slump does not meet specifications Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group r Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.