Loading...
Tax 2011B-LR130111ALI...lfiNCE GEOTECHNICRL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 01/11/2013 Report Date: 02/11/2013 Previously Reported: 01/16/2013 Sampled By: Spooner, Charles Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: Hand paving, W.bound Vanbebber at N.bound Westwood Ct Order Number: 1770 Number of Client: City of Coppell Specimens: 4 REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 140879 Material: CONCRETE Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 140879 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (lbs) Break Type Loc (PSI) (PSI) By Comments A 01/14/13: 3 6.00 28.27 100,755 Type 2 Lab 3,560 3,560 B 01/18/13: 7 6.00 28.27 123,820 Type 2 Lab 4,380 4,380 C 02/08/13: 28 6.00 28.27 157,180 Type 2 Lab 5,560 D 02/08/13: 28 6.00 28.27 159,030 Type 2 Lab 5,620 5,590 RF RM 1U R 171F] [� Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 01/12/2013 Curing Method: Standard Time Sampled: 11:35 am Time Batched: 11:03 am Temp.: Ambient: 61 °F Mix: 66 °F CONFORMS Slump: 4.5 Inches Transported By: TXI Air Content: 5.8% Source /Sampled At: Truck / Center Mix Code: 8274 Plant: TXI - Plant #141 Truck /Ticket No: 8047 / 1577487 Quantity Represented: 10 cu. yds. Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group —&-Z Perry C. K ara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. GEOTECHNICiL ,; OUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 02/01/2013 Report Date: 02/05/2013 Sampled By: Smith, Courtney Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: conc 180 yds Order Number: 1770 Client: City of Coppell REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 141798 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 141798 Page 1 of 2 Set: 1 of 2 Material: CONCRETE Location: Vanbebber St, station 17 +00, N.bound side D 03/01/13:28 E 03/01/13:28 6.00 28.27 6.00 28.27 Type 1 Specification Strength: 4,000 psi @ 28 days Slump: 1 - 3 Air Content: 3 - 5 Date Received: 02/02/2013 Curing Method: Standard Maximum 8:48 am Time Batched: Compressive Spec Age Tested Diameter Area Load /Sampled At: Truck / Center Cure Strength Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc (PSI) A 02/04/13: 3 6.00 28.27 117,375 Type 2 Lab 4,150 B 02/08/13: 7 6.00 28.27 132,900 Type 3 Lab 4,700 C 02/08/13: 7 6.00 28.27 133,685 Type 2 Lab 4,730 D 03/01/13:28 E 03/01/13:28 6.00 28.27 6.00 28.27 Type 1 Specification Strength: 4,000 psi @ 28 days Slump: 1 - 3 Air Content: 3 - 5 Date Received: 02/02/2013 Curing Method: Standard Time Sampled: 8:48 am Time Batched: 7:58 am Temp.: Ambient: 36 °F Mix: 50 °F Number of Specimens: 5 Average Strength Tested (PSI) By Comments 4,150 4,710 Lab Lab 7F1 ................. F1 Type 2 Type 3 Type 4 Type 5 Type 6 Slump: 2.0 Inches Transported By: TXI Air Content: 3.0% Source /Sampled At: Truck / Center Mix Code: 8274 Plant: TXI - Plant #141 Truck /Ticket No: 7038 / 1594640 Quantity Represented: 10 cu. yds_ at 20 cu. yds. placed of a 150 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENTAN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. fii...LlPNCE GEOTECHNICML Gft OUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Lab Date Sampled: 02/01/2013 Report Date: 02/05/2013 Type 2 Type 3 Type 4 Type 5 Type 6 Slump: 4.0 Inches Sampled By: Smith, Courtney Project: Vanbebber Drive Street Improvements Source /Sampled At: Truck / Center Mix Code: 8274 By Order Of: Chris Location: conc 180 yds Truck /Ticket No: 1525 / 1595000 Order Number: 1770 Client: City of Coppell REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 141798 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 141798 Page 2 of 2 Set: 2 of 2 Material: CONCRETE Number of Specimens: 5 Location: Vanbebber Street, station 14 +50, N.bound side Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 02/04/13 :3 6.00 28.27 91,600 Type 2 Lab 3,240 3,240 B 02/08/13: 7 6.00 28.27 95,365 Type 2 Lab 3,370 C 02/08/13 : 7 6.00 28.27 95,460 Type 2 Lab 3,380 3,370 D 03/01/13:28 E 03/01/13:28 6.00 28.27 6.00 28.27 :. ..... Type 1...... Specification Strength: 4,000 psi @ 28 days Slump: 1 - 3 Air Content: 3 - 5 Date Received: 02/02/2013 Curing Method: Standard Time Sampled: 10:50 am Time Batched: 10:13 am Temp.: Ambient: 51 °F Mix: 65 °F Lab Lab Type 2 Type 3 Type 4 Type 5 Type 6 Slump: 4.0 Inches Transported By: TXI Air Content: 5.0% Source /Sampled At: Truck / Center Mix Code: 8274 Plant: TXI - Plant #141 Truck /Ticket No: 1525 / 1595000 Quantity Represented: 10 cu. yds. at 110 cu. yds. placed of a 150 cu. yd. total placement Remarks: *Slump exceeds specifications Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. t1lfil'ICE 'P, L'�'EuEi' pTECHf11CF1L OUP C onsulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 02/05/2013 Report Date: 02/11/2013 Sampled By: Smith, Courtney Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: Vanbebber Drive Order Number: 1770 Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 141945 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 141945 Page 1 of 2 Set: 1 of 2 Material: CONCRETE Location: Vanbebber Drive, station 17 +00 Spec Age Tested Diameter Nbr (date : days) (in) A 02/08/13:3 6.00 B 02/12/13:7 6.00 C 02/12/13:7 6.00 D 03/05/13:28 6.00 E 03/05/13:28 6.00 Maximum Area Load (in 2) (Ibs) 28.27 103,415 28.27 28.27 28.27 28.27 �t Type 1 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 02/06/2013 Curing Method: Standard Time Sampled: 10:30 am Time Batched: 9:40 am Temp.: Ambient: 62 °F Mix: 65 °F Compressive Cure Strength Break Type Loc (PSI) Type 5 Lab 3,660 Lab Lab Lab Lab RM IU R Type 2 Type 3 Type 4 Number of Specimens: 5 Average Strength Tested (PSI) By Comments 3,660 FIE"I F1 Type 5 Type 6 Slump: 4.75 Inches Air Content: 6.0% Mix Code: 8274 Transported By: TXI Source /Sampled At: Truck / Center Plant: TXI - Plant #131 Truck /Ticket No: 1518 / 1598026 Quantity Represented: 10 cu. yds. at 40 cu. yds. placed of a 120 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group &_ Z " �. Perry C. Ka ara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLES) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. ALLIR'10E CiEOTECHnICRL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Report Date: 02/11/2013 Project: Vanbebber Drive Street Improvements Location: Vanbebber Drive Client: City of Coppell Date Sampled: 02/05/2013 Sampled By: Smith, Courtney By Order Of: Chris Order Number: 1770 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 141945 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 141945 Page 2 of 2 Set: 2 of 2 Compressive Material: CONCRETE Location: Vanbebber Drive, station 18 +50 Loc (PSI) (PSI) By Comments Lab Maximum 3,690 Spec Age Tested Diameter Area Load Nbr (date : days) (in) (in 2) (Ibs) Break Type A 02/08/13 :3 6.00 28.27 104,305 Type 5 B 02/12/13:7 6.00 28.27 C 02/12/13:7 6.00 28.27 D 03/05/13:28 6.00 28.27 E 03/05/13: 28 6.00 28.27 H>5'. P l [ I.h I....,'..l...i .� Type 1 Type 2 Type 3 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 02/06/2013 Curing Method: Standard Time Sampled: 12:50 pm Time Batched: 12:00 pm Temp.: Ambient: 64 °F Mix: 63 °F Number of Specimens: 5 Slump: 5.0 Inches Air Content: 5.0% Mix Code: 8274 Transported By: TXI Source /Sampled At: Truck / Center Plant: TXI - Plant #142 Truck /Ticket No: 3027 / 1598369 Quantity Represented: 10 cu. yds. at 100 cu. yds. placed of a 120 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. K ara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Compressive Average Cure Strength Strength Tested Loc (PSI) (PSI) By Comments Lab 3,690 3,690 Lab Lab Lab Lab ll ll Type 4 Type 5 Type 6 Slump: 5.0 Inches Air Content: 5.0% Mix Code: 8274 Transported By: TXI Source /Sampled At: Truck / Center Plant: TXI - Plant #142 Truck /Ticket No: 3027 / 1598369 Quantity Represented: 10 cu. yds. at 100 cu. yds. placed of a 120 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. K ara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. aarl RLLIftt'IC CEOTECHf11CFlL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 02/04/2013 Report Date: 02/06/2013 Sampled By: Smith, Courtney Project: Vanbebber Drive Street Improvements UT-1 By Order Of: Chris Location: Vanbebber Drive Type 2 Type 3 Type 4 Order Number: 1770 Client: City of Coppell Slump: 2.0 Inches Transported By: TXI Air Content: 4.0% REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 141892 Plant: TXI - Plant #141 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 141892 Page 1 of 2 Set: 1 of 2 Material: CONCRETE Number of Specimens: 5 Location: Vanbebber Drive entrance to Shell Gas Station, station 4 +00 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 02/05/13: 1 6.00 28.27 66,220 Type 2 Lab 2,340 2,340 B 02/11/13: 7 6.00 28.27 111,220 Type 2 Lab 3,930 C 02/11/13: 7 6.00 28.27 109,735 Type 2 Lab 3,880 3,910 D 03/04/13:28 E 03/04/13:28 6.00 28.27 6.00 28.27 ............................ Type 1 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 02/05/2013 Curing Method: Standard Time Sampled: 11:30 am Time Batched: 10:30 am Temp.: Ambient: 63 °F Mix: 68 °F Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 150 cu. yd. total placement Remarks: *Slump below specifications Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. akara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Lab Lab UT-1 F1 [71EI 171 Type 2 Type 3 Type 4 Type 5 Type 6 Slump: 2.0 Inches Transported By: TXI Air Content: 4.0% Source /Sampled At: Truck / Center Mix Code: 8274 Plant: TXI - Plant #141 Truck /Ticket No: 8060 / 1596752 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 150 cu. yd. total placement Remarks: *Slump below specifications Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. akara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. �WGLL IFN'ICE �OTECHfilCRL �iOUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 02/04/2013 Report Date: 02/06/2013 Sampled By: Smith, Courtney Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: Vanbebber Drive Order Number: 1770 Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 141892 Test Method.- See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 141892 Page 2 of 2 Set: 2 of 2 Material: CONCRETE Location: Vanbebber Drive, station 19 +00, N.bound side D 03/04/13:28 6.00 28.27 E 03/04/13:28 6.00 28.27 ff r IS Type 1 Type 2 Type 3 Specification Strength: 4,000 psi @ 28 days Slump: 1 - 3 Air Content: 3 - 5 Date Received: 02/05/2013 Curing Method: Standard Time Sampled: 2:40 pm Time Batched: 1:44 pm Temp.: Ambient: 64 °F Mix: 68 °F Compressive Cure Strength Loc (PSI) 3,120 4,630 4,520 Lab Lab Lab Lab Lab j(j Imo\ Type 4 Number of Specimens: 5 Average Strength Tested (PSI) By Comments 3,120 4,580 FEI Type5 Type ..3 Slump: 3.0 Inches Air Content: 3.5% Mix Code: 8274 Transported By: TXI Source /Sampled At: Truck / Center Plant: TXI - Plant #131 Truck /Ticket No: 1511 / 1597119 Quantity Represented: 10 cu. yds. at 80 cu. yds. placed of a 150 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group —4 L Perry . Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Maximum Spec Age Tested Diameter Area Load Nbr (date : days) (in) (in 2) (Ibs) Break Type A 02/05/13 :1 6.00 28.27 88,215 Type 2 B 02/11/13: 7 6.00 28.27 131,045 Type 2 C 02/11/13 : 7 6.00 28.27 127,860 Type 2 D 03/04/13:28 6.00 28.27 E 03/04/13:28 6.00 28.27 ff r IS Type 1 Type 2 Type 3 Specification Strength: 4,000 psi @ 28 days Slump: 1 - 3 Air Content: 3 - 5 Date Received: 02/05/2013 Curing Method: Standard Time Sampled: 2:40 pm Time Batched: 1:44 pm Temp.: Ambient: 64 °F Mix: 68 °F Compressive Cure Strength Loc (PSI) 3,120 4,630 4,520 Lab Lab Lab Lab Lab j(j Imo\ Type 4 Number of Specimens: 5 Average Strength Tested (PSI) By Comments 3,120 4,580 FEI Type5 Type ..3 Slump: 3.0 Inches Air Content: 3.5% Mix Code: 8274 Transported By: TXI Source /Sampled At: Truck / Center Plant: TXI - Plant #131 Truck /Ticket No: 1511 / 1597119 Quantity Represented: 10 cu. yds. at 80 cu. yds. placed of a 150 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group —4 L Perry . Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. ALlEf�'IC� GEOTECHfi1CfIL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 01/03/2013 Report Date: 01/11/2013 Sampled By: Galloway, Chaz Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: W. corner of Vanbebber Dr and Westwood Ct Order Number.- 1770 Number of Client: City of Coppell Specimens: 5 REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 140616 Material: CONCRETE Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 140616 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (lbs) Break Type Loc (PSI) (PSI) By Comments A 01/06/13:3 6.00 28.27 Lab B 01/10/13: 7 6.00 28.27 124,265 Type 2 Lab 4,390 C 01/10/13: 7 6.00 28.27 129,830 Type 2 Lab 4,590 4,490 D 01/31/13:28 6.00 28.27 Lab E 01/31/13:28 6.00 2`827 Lab Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 4,500 psi @ 28 days Slump: 5 max Slump: 3.5 Inches Transported By: Southern Star Air Content: 3 - 6 Air Content: 4.0% Source /Sampled At: Truck / Center Mix Code: Plant: Southern Star - Plant #125 Date Received: 01/04/2013 Truck /Ticket No: 1063 / 1152430 Curing Method: Standard Time Sampled: 12:39 pm Time Batched: 11:40 am Temp.: Ambient: 48 °F Mix: 60 °F Quantity Represented: 8 cu. yds. at 8 cu. yds. placed of a 8 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group ,4/� Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENTAN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.