Tax 2011B-LR130115RLLlfil'ICE 6 CEflTECHf11C19L Q4G1UP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 12/18/2012 Report Date: 01/15/2013 Previously Reported: 12/27/2012 Sampled By: Godwin, Jonathan Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: W.bound Van Bebber at Denton Tap intersection, Sloundn Order Number: 1770 Lakwood @ Van Bebber, intersection and S.bound Edgewood Dr at Van Bebber Dr Number of Client: City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 140186 Material: CONCRETE Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 140186 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (lbs) Break Type Loc (PSI) (PSI) By Comments A 12/21/12: 3 6.00 28.27 79,200 Type 2 Lab 2,800 2,800 B 12/25/12: 7 6.00 28.27 104,635 Type 3 Lab 3,700 3,700 C 01/15/13: 28 6.00 28.27 140,130 Type 3 Lab 4,960 D 01/15/13: 28 6.00 28.27 137,825 Type 2 Lab 4,870 4,920 F71 R M IU R F] EI �]' Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 3,600 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 12/19/2012 Curing Method: Standard Time Sampled: 1:05 pm Time Batched: 12:10 pm Temp.: Ambient: 72 °F Mix: 63 °F CONFORMS Slump: 3.0 Inches Transported By: TXI Air Content: 4.0% Source /Sampled At: Truck/ Center Mix Code: 8274 Plant: TXI - Plant #145 Truck /Ticket No: 8027 / 1567912 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Xakara, CME Department Manager THIS REPORTAPPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. ALLIflIYCE �j C�t?TKHflICf1L GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 01/07/2013 Report Date: 01/15/2013 Sampled By: Godwin, Jonathan Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: N.bound Lakewood Ct at VanBebber intersection Order Number: 1770 (Ibs) A Number of 6.00 Client: City of Coppell Specimens: 5 REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 140729 Material: CONCRETE Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 140729 E Page 1 of 1 6.00 Compressive Cure Strength Break Type Maximum Spec Age Tested Diameter Area Load Nbr (date : days) (in) (in Z) (Ibs) A 01/10/13:3 6.00 28.27 96,920 B 01/14/13:7 6.00 28.27 113,630 C 01/14/13:7 6.00 28.27 111,040 D 02/04/13:28 6.00 28.27 E 02/04/13:28 6.00 28.27 Compressive FIIF�91 RR IU Type 1 Type 2 Type 3 Specification Strength: 4,500 psi @ 28 days Slump: 3 - 5 Air Content: 4 - 6 Date Received: 01/08/2013 Curing Method: Standard Time Sampled: 11:55 am Time Batched: 11:18 am Temp.: Ambient: 39 °F Mix: 59 °F Average Strength Tested (PSI) By Comments 3,430 3,970 Lab Lab R 1111 [� Type 4 Type 5 Type 6 Slump: 4.75 Inches Air Content: 5.3% Mix Code: 8274 Transported By: TXI Source /Sampled At: Truck / Center Plant: TXI - Plant #131 Truck /Ticket No: 7034 / 1575448 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 50 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Cure Strength Break Type Loc (PSI) Type 2 Lab 3,430 Type 3 Lab 4,020 Type 3 Lab 3,930 FIIF�91 RR IU Type 1 Type 2 Type 3 Specification Strength: 4,500 psi @ 28 days Slump: 3 - 5 Air Content: 4 - 6 Date Received: 01/08/2013 Curing Method: Standard Time Sampled: 11:55 am Time Batched: 11:18 am Temp.: Ambient: 39 °F Mix: 59 °F Average Strength Tested (PSI) By Comments 3,430 3,970 Lab Lab R 1111 [� Type 4 Type 5 Type 6 Slump: 4.75 Inches Air Content: 5.3% Mix Code: 8274 Transported By: TXI Source /Sampled At: Truck / Center Plant: TXI - Plant #131 Truck /Ticket No: 7034 / 1575448 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 50 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. V GW0TE<NtYICfiL CROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 12/17/2012 Report Date: 01/15/2013 Previously Reported: 12/21/2012 Sampled By: Cyrus, Kenny Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: CONC 250 YDS Order Number: 1770 Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 140035 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 140035 Page 1 of 2 Set: 1 of 2 Material: CONCRETE Location: Intersection of Van Bebber and Edgewood, W.bound lane Number of Specimens: 6 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 12/18/2012 Curing Method: Standard Maximum 9:30 am Time Batched: Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 12/20/12: 3 6.00 28.27 101,645 Type 2 Lab 3,590 B 12/20/12: 3 6.00 28.27 98,385 Type 2 Lab 3,480 3,540 C 12/24/12: 7 6.00 28.27 131,090 Type 2 Lab 4,640 D 12/24/12: 7 6.00 28.27 127,825 Type 2 Lab 4,520 4,580 E 01/14/13: 28 6.00 28.27 147,855 Type 2 Lab 5,230 F 01/14/13: 28 6.00 28.27 156,520 Type 2 Lab 5,540 5,380 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 12/18/2012 Curing Method: Standard Time Sampled: 9:30 am Time Batched: 8:49 am Temp.: Ambient: 45 °F Mix: 63 °F CONFORMS Slump: 3.5 Inches Transported By: TXI Air Content: 4.9% Source /Sampled At: Truck / Center Mix Code: 8274 Plant: TXI - Plant #131 Truck /Ticket No: 3803 / 1566387 Quantity Represented: 10 cu. yds. at 30 cu. yds. placed of a 200 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group e Perry C. Kakara, CME Department Manager THIS REPORTAPPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. � UP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 12/17/2012 Report Date: 01/15/2013 Previously Reported: 12/21/2012 Sampled By: Cyrus, Kenny Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: CONIC 250 YDS Order Number: 1770 Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 140035 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 140035 Page 2 of 2 Set: 2 of 2 Material: CONCRETE Location: E. of intersection of Van Bebber and Westwood, W.bound lane' Number of Specimens: 6 RIXF RM IU EIEI [71 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 12/18/2012 Curing Method: Standard Time Sampled: 11:45 am Time Batched: 10:52 am Temp.: Ambient: 55 °F Mix: 65 °F CONFORMS Slump: 3.0 Inches Transported By: TXI Air Content: 5.2% Source /Sampled At: Truck / Center Mix Code: 8274 Plant: TXI - Plant #141 Truck /Ticket No: 3808 / 1566610 Quantity Represented: 10 cu. yds. at 130 cu. yds. placed of a 200 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (lbs) Break Type Loc (PSI) (PSI) By Comments A 12/20/12: 3 6.00 28.27 111,040 Type 2 Lab 3,930 B 12/20/12: 3 6.00 28.27 105,725 Type 2 Lab 3,740 3,830 C 12/24/12: 7 6.00 28.27 127,920 Type 2 Lab 4,520 D 12/24/12: 7 6.00 28.27 128,240 Type 2 Lab 4,540 4,530 E 01/14/13: 28 6.00 28.27 148,185 Type 2 Lab 5,240 F 01/14/13: 28 6.00 28.27 159,630 Type 2 Lab 5,650 5,440 RIXF RM IU EIEI [71 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 12/18/2012 Curing Method: Standard Time Sampled: 11:45 am Time Batched: 10:52 am Temp.: Ambient: 55 °F Mix: 65 °F CONFORMS Slump: 3.0 Inches Transported By: TXI Air Content: 5.2% Source /Sampled At: Truck / Center Mix Code: 8274 Plant: TXI - Plant #141 Truck /Ticket No: 3808 / 1566610 Quantity Represented: 10 cu. yds. at 130 cu. yds. placed of a 200 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.