Loading...
Neighborhood CU-CS130118UAI DR RANKIN, PLLC TBPE Firm #8838 January 18`h, 2012 Via Email Mr. Rick O'Dell City of Coppell Construction Inspection 255 Parkway Boulevard Coppell, TX 75019 RE: TexasBank Addition (Lot 1R1, Block A) Neighborhood Credit Union 360 S. Denton Tap Road Concrete Paving Requirements Mr. O'Dell: Based on the recommendation found in our site geotechnical report, and pursuant to our conversation during our recent preconstruction meeting, we respectfully request that the City allow our site paving construction to proceed without a hydrated lime stabilized subgrade. In lieu of the required lime stabilized subgrade, we agree to increase the fire lane and parking area pavement thickness by 1" (each). We also agree to construct the increased pavement thickness with #4 steel reinforcement bars at 18" O.C.E.W. Site paving will be constructed on subgrade compacted to 95% Standard Proctor Density. Please contact us to confirm your allowance of this subgrade preparation revision. Respectfully, ar.. Z, - Z" Donald R. Rankin, P.E. DR RANKIN, PLLC Cc: JR Aguero (Level 5) cor -2013- 0118 -drr- Odell - Coppell- Paving -Lime DR RANKIN, PLLC 2321 Daybreak Trail Plano, Texas 75093 972 3780683 WE Firm #8838