Loading...
Asbury Manor-LR 980129FUGRO-McCLELLAND (SOUTHWEST), INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Fairfield Development Report Date: January 29, 1998 PROJECT: Aviara Apartments at Bear Creek, Euless, Texas Project No.: 0771-2186 SAMPLE DATE: December 31, 1-997 CONTRACTOR: Fairfield TICKET NO.: 951220 CONCRETE SUPPLIER: TXI AMBIENT TEMP. (°F): 53 PLANT/TRUCK: 18-531 CONCRETE TEMP. (°F) (ASTM C-1064): 59 MIX ID NUMBER: 9789 TIME BATCHED: 12:00 p.m AIR (%) (ASTM C-231): TIME SAMPLED: 12:30 p.m WATER ADDED (gal): 10 WEATHER CONDITION: Clear SLUMP (in.) (ASTM C-'143): 5 LOCATION OF PLACEMENT: Main entrance on west side CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 1'2", 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) AAE 195 7 1/7/98 95000 3360 3000/28 days AAE 196 28 1/28/98 127000 4492 AAE 197 28 1/28/98 125000 4421 AAE 198 Hold ' Fracture mode is (A) unless otherwise noted Specifications: ~ Making & ASTM C-31 ~ Testing ASTM C-143,, , ,iTypesof [~ ~] ~ ~ ;Cudng: ; Methods: ASTM C-39 ; Fracture: A B C D REMARKS: Technician: Brandon Harrell FUGRO-McCLELLAND (SOUTHWEST), INC. Checked By: SMH/rm Distribution: Fairfield Development - Bob Wilson