Asbury Manor-LR 980129 (2)
FUGRO-McCLELLAND (SOUTHWEST), INC. - 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Fairfield Development Report Date: January 29, 1998 PROJECT: Aviara Apartments at Bear Creek, Euless, Texas Project No.: 0771-2186 SAMPLE DATE: December 31,- 1997' I CONTRACTOR: Fairfield TICKET NO.: 950911 CONCRETE SUPPLIER: TXI AMBIENT TEMP. (°F): 40 PLANT/TRUCK: 18-549 CONCRETE TEMP. (°F) (ASTM C-1064): 53 MIX ID NUMBER: 8271 TIME BATCHED: 9:00 a.m AIR (%) (ASTM C-231): TIME SAMPLED: 9:45 a.m WATER ADDED (gal): 10 WEATHER CONDITION: Clear SLUMP (in.) (ASTM C-143): 5.5 LOCATION OF PLACEMENT: Main entrance on west side CONCRETE' CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) AAE 191 7 1/7/98 65000 2299 3000/28 days AAE 192 28 1/28/98 90000 3183 AAE 193 28 1/28/98 93000 3289 AAE 194 Hold I Fracture mode is (A) unless otherwise noted Specificati°ns: ~ Making & ASTM C'31 i Testing ASTM C'143'' ' 'iTypes°f ~] ~'] ~ D ; Curing: i Methods: ASTM C-39 i Fracture: A B C D REMARKS: Technician: Brandon Harretl FUGRO-McCLELLAND (SOUTHWEST), INC. Checked By: ~' ~ SMH/rm Distribution: Fairfield Development- Bob Wilson