Asbury Manor-LR 971124 (2) -F-u6BD FUGRO-McCLELLAND (SOUTHWEST), INC. - 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 FIELD DENSITY REPORT CLIENT: Ryland Homes REPORT DATE: November 24, 1997 PROJECT: Asbury Manor, Coppell, Texas PROJECT NO.: 0771-2111 DATE PERFORMED.: November 11, 1997 MOISTURE/DENSITY RELATIONS Material Proctor Results Number Description Maximum Dry Density (pcf) Optimum Moisture (%) 1 Reddish brown clayey sand 117.8 13.1 TEST RESULTS TEST PROCTOR LOCATION UNIT DRY MOISTURE PERCENT OF NO. NO. WEIGHT CONTENT PERCENT MAXIMUM DENSITY 175 1 8 inch sanitary sewer, Line A-l, station 113.7 13.7 96.5 1+00, 6 feet below grade 176 1 8 inch sanitary sewer, Line A-l, station 116.5 14.0 98.9 1+00, 3 feet below grade 177 1 8 inch sanitary sewer, Line A-l, station 114.7 14.3 97.4 1+00, I foot below grade 178 1 8 inch sanitary sewer, Line A-l, station 113.1 13.4 96.0 4+00, 6 feet below grade 179 1 8 inch sanitary sewer, Line A-l, station 113.4 13.2 96.3 4+00, 3 feet below grade 180 1 8 inch sanitary sewer, Line A-l, station 114.3 13.6 97.0 4+00, 1 foot below grade 181 1 8 inch sanitary sewer, Line A-l, station 116.9 14.1 99.2 7+00, 5 feet below grade 182 1 8 inch sanitary sewer, Line A-l, station 115.1 13.7 97.7 7+00~ 3 feet below grade 193 1 8 inch sanitary sewer, Line A-l, station 116.6 13.5 99.0 7+00, I foot below grade Remarks: All densities meet project specifications unless otherwise noted. Jason Brimingham Fugro-McClelland Technician FUGRO-McCLELLAND (SOUTHWEST), INC. SMH/mv Distribution: Ryland Homes - Fred Phillips Goodwin & Marshall - Matt Goodwin City of Coppell - Garreth Campbell City of Coppell - Larry Davis Legends Construction - Jimmy Henderson