Asbury Manor-LR 971124 (2) -F-u6BD
FUGRO-McCLELLAND (SOUTHWEST), INC. -
2880 Virgo Lane; Dallas, Texas 75229
Ph (972) 484-8301; Fax (972) 620-7328
FIELD DENSITY REPORT
CLIENT: Ryland Homes REPORT DATE: November 24, 1997
PROJECT: Asbury Manor, Coppell, Texas PROJECT NO.: 0771-2111
DATE PERFORMED.: November 11, 1997
MOISTURE/DENSITY RELATIONS
Material Proctor Results
Number Description Maximum Dry Density (pcf) Optimum Moisture (%)
1 Reddish brown clayey sand 117.8 13.1
TEST RESULTS
TEST PROCTOR LOCATION UNIT DRY MOISTURE PERCENT OF
NO. NO. WEIGHT CONTENT PERCENT MAXIMUM DENSITY
175 1 8 inch sanitary sewer, Line A-l, station 113.7 13.7 96.5
1+00, 6 feet below grade
176 1 8 inch sanitary sewer, Line A-l, station 116.5 14.0 98.9
1+00, 3 feet below grade
177 1 8 inch sanitary sewer, Line A-l, station 114.7 14.3 97.4
1+00, I foot below grade
178 1 8 inch sanitary sewer, Line A-l, station 113.1 13.4 96.0
4+00, 6 feet below grade
179 1 8 inch sanitary sewer, Line A-l, station 113.4 13.2 96.3
4+00, 3 feet below grade
180 1 8 inch sanitary sewer, Line A-l, station 114.3 13.6 97.0
4+00, 1 foot below grade
181 1 8 inch sanitary sewer, Line A-l, station 116.9 14.1 99.2
7+00, 5 feet below grade
182 1 8 inch sanitary sewer, Line A-l, station 115.1 13.7 97.7
7+00~ 3 feet below grade
193 1 8 inch sanitary sewer, Line A-l, station 116.6 13.5 99.0
7+00, I foot below grade
Remarks: All densities meet project specifications unless otherwise noted.
Jason Brimingham
Fugro-McClelland Technician FUGRO-McCLELLAND (SOUTHWEST), INC.
SMH/mv
Distribution: Ryland Homes - Fred Phillips
Goodwin & Marshall - Matt Goodwin
City of Coppell - Garreth Campbell
City of Coppell - Larry Davis
Legends Construction - Jimmy Henderson