Ridgecrest-CS130206From:9727139111 02113/2013 16:19 #515 P.0021004 February 13, 2013 Colin W. Helffrich, P. E. Dowdey, Anderson & Associates, Inc. 5225 Village Creek Drive, Suite 200 Plano, Texas 75093 Re: Pavement Recommendation Ridgecrest Estates Residential Development Coppell, Texas BCS Project Number: 123 -005 (Revised) Dear Mr. Helffrich: As requested, Bryant Consulting Services (BCS) has evaluated rigid pavement (concrete) for the proposed residential development roadways on a 6 -inch cement stabilized subgrade. Suburade Modification Recommendation BCS assumed a modified subgrade minimum unconfined compressive strength of 160 psi, which is commonly used in this area. Laboratory unconfined compressive strength tests were performed on cement modified subgrade soils (3%, 40/6, 5% and 6% cement molded at approximate optimum moisture). Due to time constraints, BCS based our results on a 3 -day curing period and unconfined compressive strength, rather than the normal 7 -days used for cement. Since the 7-day unconfined compressive strength will exceed the 3 -day strength, it is BCS's opinion that a compliant 3 -day break is suitable and adequate. Based on our test results, BCS recommends applying 4% cement by weight to stabilize the subgrade under roads at the subdivision. The results of our unconfined compressive strength testing at the recommended 4% cement are provided to the moderate brown silty clayey sand material (sample L -3) and grayish brown sandy clay material (sample L -6) are provided in Table 1 (next page). In addition, the table provides our recommended cement application rate in pounds per square yard (PSY). Bryant Consulting Services, LLC 3360 Wiley Post Road, Suite 100 - Carrollton, Texas 76006 Phone: 972.713.9109 • Fax: 972.713.9171 • TX Firm Registration: F -11264 www.bryantconsultingservices.com - HUB Certified From:9727139171 Ridgecrest Estates Pavement Recommendation Coppell, Texas 02/13/2013 16:19 #515 P.003 /004 TABLE 1 — 4% CEMENT SUBGRADE STABILIZATteM TFCT Q=Q11111 Tc Page 2 The cement should be thoroughly mixed and blended with the top 6 inches of the subgrade soil under the roadway. The cement stabilization should extend a minimum of 1 foot beyond the width of the roads on both sides, or extend the minimum distance required by the City of Coppell, whichever is greater. The cement modified soil subgrade should be compacted to a minimum of 95 percent of ASTM D 698, at a minimum of +2 percent of the soils optimum moisture content determined by that test. Density testing should be performed on the same day as final compaction. BCS should collect representative samples of the cement stabilized material immediately after mixing the mold and test. Pavement Design The designs were analyzed using AASHTO procedures, and the criterion for the residential pavement section includes a 20 -year design life, 0% growth, and a maximum Annual Equivalent Single Axle Load (ESAL) 50,000. The following parameters were used in the below preliminary pavement analysis: 3,600 PSI Concrete Concrete Section Thickness Initial Serviceability, p° Terminal Serviceability, pt Reliability, R Overall Standard Deviation Overall Drainage Coef., Cd Load Transfer Coefficient, J Mod. of Sub. Reaction, k 28-day Conc. Mod. of Rupture 28 -day Elastic Mod. of Rupture Design Life SCI Project 125 -005 6 Inches 4.5 2.5 85% 0.34 0.7 3.2 250 psi /in 450 psi 3,600,000 psi 20 years +0% Bryant Consulting services, LLC •- Confidential / Copyright ® 2013 :o n ed. 164 • FModerate Brown Silty Clayey Sand L -3 120.2 4°16 190 22 Grayish Brown Sandy Clay L -6 113.4 4% 222 22 The cement should be thoroughly mixed and blended with the top 6 inches of the subgrade soil under the roadway. The cement stabilization should extend a minimum of 1 foot beyond the width of the roads on both sides, or extend the minimum distance required by the City of Coppell, whichever is greater. The cement modified soil subgrade should be compacted to a minimum of 95 percent of ASTM D 698, at a minimum of +2 percent of the soils optimum moisture content determined by that test. Density testing should be performed on the same day as final compaction. BCS should collect representative samples of the cement stabilized material immediately after mixing the mold and test. Pavement Design The designs were analyzed using AASHTO procedures, and the criterion for the residential pavement section includes a 20 -year design life, 0% growth, and a maximum Annual Equivalent Single Axle Load (ESAL) 50,000. The following parameters were used in the below preliminary pavement analysis: 3,600 PSI Concrete Concrete Section Thickness Initial Serviceability, p° Terminal Serviceability, pt Reliability, R Overall Standard Deviation Overall Drainage Coef., Cd Load Transfer Coefficient, J Mod. of Sub. Reaction, k 28-day Conc. Mod. of Rupture 28 -day Elastic Mod. of Rupture Design Life SCI Project 125 -005 6 Inches 4.5 2.5 85% 0.34 0.7 3.2 250 psi /in 450 psi 3,600,000 psi 20 years +0% Bryant Consulting services, LLC •- Confidential / Copyright ® 2013 From:9727139171 Ridgeereat Estates Pavement Recommendation Coppell, Texas 02/13/2013 16:20 #1515 P.004I004 Page 2 Based on the above parameters, the analysis yielded an 18 -kip Equivalent Single Axle Load (ESAL) of 252 daily repetitions (63 Fully Loaded) for a 6 -inch section of PCC pavement. The analysis assumed that the 3,600 PSI concrete pavement is placed on a 6 -inch cement stabilized subgrade as discussed above. If. during the course of this project we can be of further assistance, please do not hesitate to contact us. Sincerely, BRYANT CONSUL TX FIRM REa18TRATl[� Confldentlal / Coavrldfit Brent L. u as, P.E. Vice Prokidedit Sandip Tamrakar, E.I.T. Graduate Engineer ,SERVICES LLC ' -11204 s 2013 —0„�►V►ttt�t cc: Larry Jackson, David Weekley Homes BCI Project 125 -006 Bryant consulting Services, LLC — Confldentiat / Co pyright ®2013 February 6, 2013 Colin W. Helffrich, P.E. Dowdey, Anderson & Associates, Inc. 5225 Village Creek Drive, Suite 200 Plano, Texas 75093 Re: Pavement Recommendation Ridgecrest Estates Residential Development Coppell, Texas BCS Project Number: 12S -005 Dear Mr. Helffrich: As requested, Bryant Consulting Services (BCS) has evaluated rigid pavement (concrete) for the proposed residential development roadways on compacted native soils with no subgrade improvement. The designs were analyzed using AASHTO procedures and the criterion for the residential pavement section includes a 25 -year design life, 0% growth, and a maximum Annual Equivalent Single Axle Load (ESAL) 50,000. The following parameters were used in the below preliminary pavement analysis: 3,600 PSI Concrete Concrete Section Thickness 8 inches Initial Serviceability, po 4.5 Terminal Serviceability, pt 2.5 Reliability, R 85% Overall Standard Deviation 0.34 Overall Drainage Coef., Cd 0.7 Load Transfer Coefficient, J 3.2 Mod. of Sub. Reaction, k 72 psi/ in 28 -day Conc. Mod. of Rupture 450 psi 28 -day Elastic Mod. of Rupture 3,600,000 psi Design Life 25 years +0% Bryant Consulting Services, LLC 3360 Wiley Post Road, Suite 100 • Carrollton, Texas 75006 Phone: 972.713.9109 • Fax: 972.713.9171 • TX Firm Registration: F -11264 vnAaw .bryantconsultingservices.com , HUB Certified Ridgecrest Estates Pavement Recommendation Coppell, Texas Page 2 Based on the above parameters, the analysis yielded an 18 -kip Equivalent Single Axle Load (ESAL) of 252 daily repetitions (63 Fully Loaded) for an 8 -inch section of PCC pavement. The analysis assumed that the 3,600 PSI concrete pavement is placed on an unmodified subgrade. It has been a pleasure to perform this work for you. If, during the course of this project we can be of further assistance, please do not hesitate to call. Sincerely, BRYANT CONSULTING SERVICES LLC TX FIRM REGISTRATION NO.: F -11264 Confidential 1 C yr g r3��►,��ut�ttt ~PEE OF »f� * • ........ . D A' GL �...... .....,.., Brent L. Dougla , P. rtr A °• 98065 ViCePresid t sjo�AtPN tt�ttit���~'` Sandip Tamrakar, E.I.T. Graduate Engineer BCI Project 12S -005 Bryant Consulting Services, LLC — Confidential I Copyright cQ 2013 I U U C N 0 U ro U 0 N N od 1,0' C 0 N Q 0 0 U U L U llp O N co a' cinrwai 1r TI) Pr CONSTRUCTED BY c HOMEBUILDER N h N n J W LL It W W n m N O Q a co N O N 0 4' 50' ROW 10 0' 30' b —b 5 SAWED LONGITUDINAL ij ROW DUMMY JOINT WITH APPR0VED SEALER I 2% 12" 4" COMPACTED SUBGRADE TO A DENSITY NOT LES THAN 95Z STANDARD PROCTOR DENSITY 6" MOUNTABLE CURB 7 6" PARABOLIC CROWN 3 Q 10.0' 5' I 4' 1.0' 29' 12" 8" THK 3600 PSI CONC PANT W/ NO 4 BARS 18" 0.0 E W. TYPICAL PAVEMENT SECTION N.T.S.