Westhaven-LR130202
REPORT OF FIELD
COMPACTION TESTS
2209 Wisconsin Street, Suite 100
Dallas, Texas 75229
II
Geotechnical Construction Materials Environmental
www.alphatesting.com
TBPE Firm No. 813
TESTED FOR:Standard Pacific Homes - IrvingDATE: 02/02/13
Irving, Texas
PROJECT:OUR REPORT NO.:130127-19
Westhaven
Coppell, Texas
TEST DATA:TECHNICIAN:Don Hinton
MAXIMUM LABIN PLACEIN PLACE
OPTIMUM
TESTSOIL ID
ELEV.
PERCENT
DATE
COMMENT*
MOISTUREDRY DENSITYMOISTUREDRY DENSITY
NO.NUMBER
COMPACTION
DEPTH
%PCF%PCF
21402/02/13FG-6.029.2124.412.9118951-A
21502/02/13FG-7.029.2124.413.2119961-A
21602/02/13FG-6.0111.9117.912.31191011-A
21702/02/13FG-7.0111.9117.913.81181001-A
21802/02/13FG-5.0111.9117.914.0117991-A
21902/02/13FG-5.0111.9117.912.71181001-A
22002/02/13FG-7.0111.9117.913.9117991-A
TEST LOCATION:Phase I
21420' S and 45' W from the NE Corner of Block G, Pad 1
21520' S and 45' W from the NE Corner of Block G, Pad 2
21620' S and 45' W from the NE Corner of Block G, Pad 3
21720' S and 45' W from the NE Corner of Block G, Pad 4
21820' S and 45' W from the NE Corner of Block G, Pad 7
21920' S and 45' W from the NE Corner of Block G, Pad 8
22020' S and 45' W from the NE Corner of Block G, Pad 9
1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted,
4. CEMENT TREATEDD. RETEST
Attef Abushakra, P.E.
ALPHA TESTING, INC.
Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with
express approval of ALPHA. The
use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities
of apparently identical or similar
specimens.
REPORT OF FIELD
COMPACTION TESTS
2209 Wisconsin Street, Suite 100
Dallas, Texas 75229
II
Geotechnical Construction Materials Environmental
www.alphatesting.com
TBPE Firm No. 813
TESTED FOR:Standard Pacific Homes - IrvingDATE: 02/02/13
Irving, Texas
PROJECT:WesthavenOUR REPORT NO.:130127-19A
Coppell, Texas
TEST DATA:TECHNICIAN:Don Hinton
OPTIMUMMAXIMUM LABIN PLACEIN PLACE
TESTSOIL ID
ELEV.
PERCENT
DATECOMMENT*
MOISTUREDRY DENSITYMOISTUREDRY DENSITY
NO.NUMBER
COMPACTION
DEPTH
%PCF%PCF
22102/02/13FG-8.0111.9117.914.9115981-A
22202/02/13FG-9.0111.9117.913.9116991-A
22302/02/13FG-5.0111.9117.915.3114971-A
22402/02/13FG-6.0111.9117.916.0112951-A
22502/02/13FG-5.0111.9117.915.4114961-A
22602/02/13FG-6.0111.9117.913.7116981-A
22702/02/13FG-4.0111.9117.915.9113951-A
TEST LOCATION:Phase I
22120' S and 45' W from the NE Corner of Block G, Pad 10
22220' S and 45' W from the NE Corner of Block G, Pad 11
22320' N and 30' E from the SW Corner of Block G, Pad 1
22420' N and 30' E from the SW Corner of Block G, Pad 2
22520' N and 30' E from the SW Corner of Block G, Pad 3
22620' N and 30' E from the SW Corner of Block G, Pad 4
22720' N and 30' E from the SW Corner of Block G, Pad 7
1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted,
4. CEMENT TREATEDD. RETEST
Attef Abushakra, P.E.
ALPHA TESTING, INC.
Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with
express approval of ALPHA. The
use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities
of apparently identical or similar
specimens.
REPORT OF FIELD
COMPACTION TESTS
2209 Wisconsin Street, Suite 100
Dallas, Texas 75229
II
Geotechnical Construction Materials Environmental
www.alphatesting.com
TBPE Firm No. 813
TESTED FOR:Standard Pacific Homes - IrvingDATE: 02/02/13
Irving, Texas
PROJECT:OUR REPORT NO.:130127-19B
Westhaven
Coppell, Texas
TEST DATA:TECHNICIAN:Don Hinton
MAXIMUM LABIN PLACEIN PLACE
OPTIMUM
TESTSOIL ID
ELEV.
PERCENT
DATE
COMMENT*
MOISTUREDRY DENSITYMOISTUREDRY DENSITY
NO.NUMBER
COMPACTION
DEPTH
%PCF%PCF
22802/02/13FG-8.029.2124.411.6120971-A
22902/02/13FG-7.029.2124.411.9121981-A
23002/02/13FG-7.029.2124.411.4121971-A
23102/02/13FG-6.029.2124.410.7122981-A
23202/02/13FG-4.029.2124.410.6119961-A
23302/02/13FG-5.029.2124.411.4121981-A
23402/02/13FG-5.029.2124.410.8120961-A
TEST LOCATION:Phase I
22820' N and 30' E from the SW Corner of Block G, Pad 11
22920' N and 30' E from the SW Corner of Block G, Pad 10
23030' S and 55' W from the NE Corner of Block G, Pad 11
23130' S and 55' W from the NE Corner of Block G, Pad 10
23230' S and 55' W from the NE Corner of Block G, Pad 1
23330' S and 55' W from the NE Corner of Block G, Pad 2
23430' S and 55' W from the NE Corner of Block G, Pad 4
1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted,
4. CEMENT TREATEDD. RETEST
Attef Abushakra, P.E.
ALPHA TESTING, INC.
Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with
express approval of ALPHA. The
use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities
of apparently identical or similar
specimens.
REPORT OF FIELD
COMPACTION TESTS
2209 Wisconsin Street, Suite 100
Dallas, Texas 75229
II
Geotechnical Construction Materials Environmental
www.alphatesting.com
TBPE Firm No. 813
TESTED FOR:Standard Pacific Homes - IrvingDATE: 02/02/13
Irving, Texas
PROJECT:WesthavenOUR REPORT NO.:130127-19C
Coppell, Texas
TEST DATA:TECHNICIAN:Don Hinton
OPTIMUMMAXIMUM LABIN PLACEIN PLACE
TESTSOIL ID
ELEV.
PERCENT
DATECOMMENT*
MOISTUREDRY DENSITYMOISTUREDRY DENSITY
NO.NUMBER
COMPACTION
DEPTH
%PCF%PCF
23502/02/13FG-13.029.2124.410.91251001-A
23602/02/13FG-12.029.2124.49.81251011-A
23702/02/13FG-11.029.2124.49.21251001-A
TEST LOCATION:Phase I
235Westhaven Road at Station 20+52
236Westhaven Road at Station 20+55
237Westhaven Road at Station 20+65
1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted,
4. CEMENT TREATEDD. RETEST
Attef Abushakra, P.E.
ALPHA TESTING, INC.
Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with
express approval of ALPHA. The
use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities
of apparently identical or similar
specimens.