Westhaven-LR130202 REPORT OF FIELD COMPACTION TESTS 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 II Geotechnical Construction Materials Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR:Standard Pacific Homes - IrvingDATE: 02/02/13 Irving, Texas PROJECT:OUR REPORT NO.:130127-19 Westhaven Coppell, Texas TEST DATA:TECHNICIAN:Don Hinton MAXIMUM LABIN PLACEIN PLACE OPTIMUM TESTSOIL ID ELEV. PERCENT DATE COMMENT* MOISTUREDRY DENSITYMOISTUREDRY DENSITY NO.NUMBER COMPACTION DEPTH %PCF%PCF 21402/02/13FG-6.029.2124.412.9118951-A 21502/02/13FG-7.029.2124.413.2119961-A 21602/02/13FG-6.0111.9117.912.31191011-A 21702/02/13FG-7.0111.9117.913.81181001-A 21802/02/13FG-5.0111.9117.914.0117991-A 21902/02/13FG-5.0111.9117.912.71181001-A 22002/02/13FG-7.0111.9117.913.9117991-A TEST LOCATION:Phase I 21420' S and 45' W from the NE Corner of Block G, Pad 1 21520' S and 45' W from the NE Corner of Block G, Pad 2 21620' S and 45' W from the NE Corner of Block G, Pad 3 21720' S and 45' W from the NE Corner of Block G, Pad 4 21820' S and 45' W from the NE Corner of Block G, Pad 7 21920' S and 45' W from the NE Corner of Block G, Pad 8 22020' S and 45' W from the NE Corner of Block G, Pad 9 1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted, 4. CEMENT TREATEDD. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. REPORT OF FIELD COMPACTION TESTS 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 II Geotechnical Construction Materials Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR:Standard Pacific Homes - IrvingDATE: 02/02/13 Irving, Texas PROJECT:WesthavenOUR REPORT NO.:130127-19A Coppell, Texas TEST DATA:TECHNICIAN:Don Hinton OPTIMUMMAXIMUM LABIN PLACEIN PLACE TESTSOIL ID ELEV. PERCENT DATECOMMENT* MOISTUREDRY DENSITYMOISTUREDRY DENSITY NO.NUMBER COMPACTION DEPTH %PCF%PCF 22102/02/13FG-8.0111.9117.914.9115981-A 22202/02/13FG-9.0111.9117.913.9116991-A 22302/02/13FG-5.0111.9117.915.3114971-A 22402/02/13FG-6.0111.9117.916.0112951-A 22502/02/13FG-5.0111.9117.915.4114961-A 22602/02/13FG-6.0111.9117.913.7116981-A 22702/02/13FG-4.0111.9117.915.9113951-A TEST LOCATION:Phase I 22120' S and 45' W from the NE Corner of Block G, Pad 10 22220' S and 45' W from the NE Corner of Block G, Pad 11 22320' N and 30' E from the SW Corner of Block G, Pad 1 22420' N and 30' E from the SW Corner of Block G, Pad 2 22520' N and 30' E from the SW Corner of Block G, Pad 3 22620' N and 30' E from the SW Corner of Block G, Pad 4 22720' N and 30' E from the SW Corner of Block G, Pad 7 1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted, 4. CEMENT TREATEDD. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. REPORT OF FIELD COMPACTION TESTS 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 II Geotechnical Construction Materials Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR:Standard Pacific Homes - IrvingDATE: 02/02/13 Irving, Texas PROJECT:OUR REPORT NO.:130127-19B Westhaven Coppell, Texas TEST DATA:TECHNICIAN:Don Hinton MAXIMUM LABIN PLACEIN PLACE OPTIMUM TESTSOIL ID ELEV. PERCENT DATE COMMENT* MOISTUREDRY DENSITYMOISTUREDRY DENSITY NO.NUMBER COMPACTION DEPTH %PCF%PCF 22802/02/13FG-8.029.2124.411.6120971-A 22902/02/13FG-7.029.2124.411.9121981-A 23002/02/13FG-7.029.2124.411.4121971-A 23102/02/13FG-6.029.2124.410.7122981-A 23202/02/13FG-4.029.2124.410.6119961-A 23302/02/13FG-5.029.2124.411.4121981-A 23402/02/13FG-5.029.2124.410.8120961-A TEST LOCATION:Phase I 22820' N and 30' E from the SW Corner of Block G, Pad 11 22920' N and 30' E from the SW Corner of Block G, Pad 10 23030' S and 55' W from the NE Corner of Block G, Pad 11 23130' S and 55' W from the NE Corner of Block G, Pad 10 23230' S and 55' W from the NE Corner of Block G, Pad 1 23330' S and 55' W from the NE Corner of Block G, Pad 2 23430' S and 55' W from the NE Corner of Block G, Pad 4 1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted, 4. CEMENT TREATEDD. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. REPORT OF FIELD COMPACTION TESTS 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 II Geotechnical Construction Materials Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR:Standard Pacific Homes - IrvingDATE: 02/02/13 Irving, Texas PROJECT:WesthavenOUR REPORT NO.:130127-19C Coppell, Texas TEST DATA:TECHNICIAN:Don Hinton OPTIMUMMAXIMUM LABIN PLACEIN PLACE TESTSOIL ID ELEV. PERCENT DATECOMMENT* MOISTUREDRY DENSITYMOISTUREDRY DENSITY NO.NUMBER COMPACTION DEPTH %PCF%PCF 23502/02/13FG-13.029.2124.410.91251001-A 23602/02/13FG-12.029.2124.49.81251011-A 23702/02/13FG-11.029.2124.49.21251001-A TEST LOCATION:Phase I 235Westhaven Road at Station 20+52 236Westhaven Road at Station 20+55 237Westhaven Road at Station 20+65 1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted, 4. CEMENT TREATEDD. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.