Letter Of Transmittal
2/14/2013
9:46:13AM
Report: 128946 Contains the Following Reports:
Report,-Description
• Submittal#10630 for Project:Ridgecrest Estates-Coppell
• Detailed Data for Submittal#10630
• Backup Data for Mix:8272-141 of Submittal#10630 for Project:Ridgecrest Estates-Coppell
• Backup Data for Mix:8273SF-141 of Submittal#10630 for Project:Ridgecrest Estates-Coppell
• Backup Data for Mix:8274-141 of Submittal#10630 for Project:Ridgecrest Estates-Coppell
• Cement Mill Certificate(December 2012).pdf attachment for Submittal#10630 for Project:Ridgecrest Estates-Coppell
• Bridgeport Man Sand (January 2013).pdf attachment for Submittal#10630 for Project:Ridgecrest Estates-Coppell
• Bridgeport Stone (January 2013).pdf attachment for Submittal#10630 for Project:Ridgecrest Estates-Coppell
• TXI Concrete Sand (January 2013).pdf attachment for Submittal#10630 for Project:Ridgecrest Estates-Coppell
• MB-AE 90(January 2013).pdf attachment for Submittal#10630 for Project:Ridgecrest Estates-Coppell
• Pozzolith 100XR(January 2013).pdf attachment for Submittal#10630 for Project:Ridgecrest Estates-Coppell
• Pozzolith 200N(Janaury 2013).pdf attachment for Submittal#10630 for Project:Ridgecrest Estates-Coppell
te-/
'° //
j 'acJr'e
1341 West Mockingbird Lane f. lids.le.ras 75247 ° 972-647.6700
bd.COM
February 14,2013
Conatser Construction,Inc.
P.O.Box 15448
Fort Worth,TX. 76119
Attn:Mr.Bill Hurst
RE: Ridgecrest Estates-Coppell
Mix Code Numbers
8272,8273SF,8274
The attached concrete mix designs utilizing the appropriate ASTM C-33 or ASTM C-330 aggregate are
proposed for use on the above referenced project for ready-mixed concrete to be furnished by TXI.
To ensure that the correct mix is delivered to your project,please order by the mix design number which
appears in the left hand corner of the mix design.
TXI certifies that the above mix designs,when ordered by specified design identity,and delivered by TXI,will
meet or exceed the indicated design strength at the designated age when tested in accordance with the
applicable and current ASTM Standards C 31,C 39,C 78,C 172,C 293,applicable provisions of C 94, and
evaluated in accordance with applicable provisions of the ACI building code.
TXI would like to be included on your mailing list to receive all test reports.ASTM C 94 entitles a
manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance.
Contact us if you have any questions or require any additional information.Please notify TXI of approval of the
proposed mix design prior to its use. Failure to notify us prior to first placement shall constitute acceptance.To
ensure that the proper mix design is ordered,please send a copy of this letter,after approval,to the above
referenced project to be used by the person ordering the concrete for this job.
The information contained in this submittal is confidential and the exclusive property of TXI.It cannot be
copied,duplicated or disclosed to third parties without the expressed written consent of TXI.
Sincerely,
TXI Operations,LP
Victor H.Villarreal
Pumping Notes:
1. 5"minimum diameter lines with no reduction to smaller lines.
2. Keep rubber hose to absolute minimum length and plan pipe with as few 90 degree angles as
possible.
3. Samples for slump and strength tests should be taken at discharge end of hose for strength
guarantee to be valid.
4. To prime pump lines,a minimum of 8.0 sack grout is recommended for lubrication. In the case of
strength concrete,equivalent strength grout should be used if the grout remains in the placement.
5. Pump mixes are based on minimum cement content pumped at ground level.As pump line
increases in length or height and/or layout configuration changes,mix design modifications may be
required to assure strength and pumpability at additional cost to the contractor.
6. TXI cannot control,and is therefore not responsible for excessive loss of entrained air content
when loss occurs as a result of boom configuration or free fall discharge from hose. To ensure
minimum air loss when pumping,maintain a continuous flow of concrete through the entire length of
pipe and do not subject concrete to free fall.
7. The term"pumpable concrete"refers to concrete which is capable of being transported through an
apparatus which forces concrete to the placing position through a pipeline or hose as long as the
recommendations indicated above are followed. The term"pumpable concrete"does not relate to
concrete proportioned in a particular manner or containing a specific type of product.
Strength of lightweight mix designs valid provided strength specimens are air cured in accordance
with ASTM Test Method C 567-05,section 7.3 except as modified in section 8.1,alternative method,
ASTM Specification C 330-04.
Unless otherwise indicated, when the concrete temperature at point of placement exceeds 90 degrees
Fahrenheit,TXI will guarantee the strength performance of the mix design(s)herein submitted up to a
maximum placement temperature of 100 degrees Fahrenheit using an ASTM C 494 Type D retarding
water-reducer,as long as the concrete is placed within 75 minutes from batch time.Unless otherwise
indicated,strength of plain concrete guaranteed up to a maximum placement temperature of 85
degrees Fahrenheit.
We are enclosing all available back up data for the referenced mix design(s). If the strength
information is not available,or is insufficient,confirmation tests may have to be conducted by your
lahnratnry
le) 13.14 West Mockingbird Lane DaIt s.Texas 75217 • 972.617.6700
txi.cam
Customer: Conatser Construction,Inc. Date Issued: February 14,2013
Project: Ridgecrest Estates-Coppell Plant: 141
Lewisville
8272 5.00SK ADMIX/AEA 1"CS
Flatwork, Walks
Description Admix. SSD Weight(lb)
Type 1/II Cement 470
1"-#4 Crushed Stone 1840
Bridgeport Sand 541
Concrete Sand 811
City Water 258
MB-AE 90 0.3 to 4.0 oz/cwt CM
Pozzolith 200N 3.0 to 4.0 oz/cwt CM
Specified F'c: 3,000 psi @ 28 days TOTAL 3920
Specified Slump: 3.00 To 5.00 in. Designed Unit Weight: 145.2 lbs./cu.ft.
Specified Air: 3.00 To 6.00% Designed W/C+P Ratio: 0.55
Designed Air: 4.5 % Designed Volume: 27.00 cu.ft.
NOTES:
TXI has no knowledge or authority regarding where this mix is to be placed(if other than the defined use on
page 1),therefore it is the responsibility of the project architect/engineer, and or contractor to insure that the
above designed mix parameters of compressive strength,water cement ratio,cement content,and air content,
are appropriate for the anticipated environmental conditions(ie.ACI-318 sections 4.1-4.3,and the local
Building Codes).Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and
Section 1.6.3., and per ASTM C-31.
Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the
right to adjust these dosages to meet the changes in jobsite demands.
This mix has been designed to meet the requirements of the documents received from the project,and/or your
verbal request. Aggregate weights may change depending on gradations or specific gravity of material.
Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI.Any use or
dissemination without permission is a violation of federal criminal law.
COMMENTS:
&AI 1311 West Mockingbird lane . Da1[as.`Iexas 7521/ - 972447.670D
tx.com
Date: 2/14/2013 Units: US
Mix Name: 8272 Mix Strength: 3,000 PSI at 28 Days
STRENGTH SUMMARY, Compression 6" x 12"
Strengths
No. Of Avg Avg Avg 28 Avg Acc Accept Std AC1318
Tests Slump Air Day Age Age Dev Req'd
30 4.29 4.34 4590 4590 28 520 3700
DETAILED STRENGTH, Compression 6" x 12"
Plant Slump Air Strengths Acc Acc Age
28 Day Acc Age Age Run Avg 3
140 4.75 5.00 4550 4550 28
140 4.50 4.60 4060 4060 28
140 4.50 4.90 4210 4210 28 4270
138 4.25 4.50 4610 4610 28 4290
140 4.00 3.00 3890 3890 28 4240
144 4.50 4.00 4500 4500 28 4330
144 3.50 4.50 6000 6000 28 4800
140 4.50 4.10 5010 5010 28 5170
140 3.00 3.60 5290 5290 28 5430
140 4.75 4.90 4240 4240 28 4850
140 4.50 4.40 4110 4110 28 4550
140 4.50 4.20 4670 4670 28 4340
141 4.75 5.00 5310 5310 28 4700
141 4.50 4.20 5450 5450 28 5140
141 4.50 3.00 4870 4870 28 5210
146 4.75 5.60 4690 4690 28 5000
122 4.00 3.80 4270 4270 28 4610
122 4.25 5.25 4330 4330 28 4430
131 4.00 5.50 4670 4670 28 4420
131 4.50 4.10 5060 5060 28 4690
128 4.50 4180 4180 28 4640
122 3.50 3.90 4320 4320 28 4520
122 4.25 4400 4400 28 4300
140 4.75 4.90 4430 4430 28 4380
150 4.00 5.80 4730 4730 28 4520
146 3.50 3810 3810 28 4330
146 4.50 2.20 4080 4080 28 4210
146 4.00 3.10 3940 '3940 28 3940
146 4.50 4.50 4760 4760 28 4260
14F A 7S A mn moon Goon
C411:10411115) 1311 West Mockingbird Lane • Dads l xds 752.17 9726'1T 6700
txr<.com'
Customer: Conatser Construction,Inc. Date Issued:February 14,2013
Project: Ridgecrest Estates-Coppell Plant: 141
Lewisville
8273SF 5.50SK ADMIX/AEA 1"CS
Main Line Paving
Description Admix. SSD Weight(lb)
Type I/II Cement 517
1"-#4 Crushed Stone 1840
Concrete Sand 1356
City Water 242
MB-AE 90 0.3 to 4.0 oz/cwt CM
Pozzolith 100XR 2.0 to 4.0 oz/cwt CM
Specified F'c: 3,600 psi @ 28 days TOTAL 3955
Specified Slump: 1.00 To 3.00 in. Designed Unit Weight: 146.5 lbs./cu.ft.
Specified Air: 3.00 To 6.00 % Designed W/C+P Ratio: 0.47
Designed Air: 4.5 % Designed Volume: 27.00 cu.ft.
NOTES:
TXI has no knowledge or authority regarding where this mix is to be placed(if other than the defined use on
page 1),therefore it is the responsibility of the project architect/engineer,and or contractor to insure that the
above designed mix parameters of compressive strength,water cement ratio,cement content,and air content,
are appropriate for the anticipated environmental conditions(ie.ACI-318 sections 4.1-4.3,and the local
Building Codes).Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and
Section 1.6.3.,and per ASTM C-31.
Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the
right to adjust these dosages to meet the changes in jobsite demands.
This mix has been designed to meet the requirements of the documents received from the project,and/or your
verbal request. Aggregate weights may change depending on gradations or specific gravity of material.
Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI.Any use or
dissemination without permission is a violation of federal criminal law.
COMMENTS:
1391 West Mockingbird Lane Dallas.lexas 75217 - 9/2,617.670D
txLcom
Date: 2/14/2013 Units: US
Mix Name: 8273SF Mix Strength: 3,600 PSI at 28 Days
STRENGTH SUMMARY, Compression 6" x 12"
Strengths
No. Of Avg Avg Avg 28 Avg Acc Accept Std ACI318
Tests Slump Air Day Age Age Dev Req'd
30 1.98 3.65 6590 6590 28 780 4910
DETAILED STRENGTH, Compression 6" x 12"
Plant Slump Air Strengths Acc Acc Age
28 Day Acc Age Age Run Avg 3
128 2.50 4.50 5780 5780 28
128 2.00 4.00 7040 7040 28
131 8760 8760 28 7190
150 2.75 3.50 5870 5870 28 7220
150 2.50 2.20 7050 7050 28 7230
140 2.50 3.10 5630 5630 28 6180
143 1.50 5370 5370 28 6020
128 1.50 6380 6380 28 5790
150 2.75 3.60 5740 5740 28 5830
134 1.50 6550 6550 28 6220
134 2.00 5570 5570 28 5950
131 2.75 6050 6050 28 6050
134 2.25 6100 6100 28 5900
140 2.00 8100 8100 28 6750
131 1.25 3.00 8090 8090 28 7430
134 1.00 6770 6770 28 7650
134 2.25 5250 5250 28 6700
131 1.75 3.20 7150 7150 28 6390
134 1.50 3.30 6020 6020 28 6140
122 2.00 3.50 6380 6380 28 6520
131 1.75 3.20 6450 6450 28 6280
131 2.00 3.10 7220 7220 28 6680
131 2.50 3.00 7010 7010 28 6890
131 1.75 3.80 7610 7610 28 7280
131 2.25 4.60 6470 6470 28 7030
131 2.00 4.70 6770 6770 28 6950
131 2.00 5.10 6370 6370 28 6540
122 1.00 6300 6300 28 6480
131 2.00 4.80 6800 6800 28 6490
1)) 0 nn 0 l n -rnnn -7nnn
1311 West Mockingbird lane • Dalfas.'Texas 75297 • 9n 617.6670
txi.COM
Customer: Conatser Construction,Inc. Date Issued:February 14,2013
Project: Ridgecrest Estates-Coppell Plant: 141
Lewisville
8274 6.00SK ADMIX/AEA 1"CS
Hand Placed Paving, Structures
Description Admix. SSD Weight(lb)
Type I/II Cement 564
1"-#4 Crushed Stone 1840
Concrete Sand 1273
City Water 258
MB-AE 90 0.3 to 4.0 oz/cwt CM
Pozzolith 200N 3.0 to 4.0 oz/cwt CM
Specified F'c: 4,000 psi @ 28 days TOTAL 3935
Specified Slump: 3.00 To 5.00 in. Designed Unit Weight: 145.7 lbs./cu.ft.
Specified Air: 3.00 To 6.00% Designed W/C+P Ratio: 0.46
Designed Air: 4.5 % Designed Volume: 27.00 cu.ft.
NOTES:
TXI has no knowledge or authority regarding where this mix is to be placed(if other than the defined use on
page 1),therefore it is the responsibility of the project architect/engineer,and or contractor to insure that the
above designed mix parameters of compressive strength,water cement ratio,cement content,and air content,
are appropriate for the anticipated environmental conditions(ie.ACI-318 sections 4.1-4.3,and the local
Building Codes).Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and
Section 1.6.3.,and per ASTM C-31.
Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the
right to adjust these dosages to meet the changes in jobsite demands.
This mix has been designed to meet the requirements of the documents received from the project,and/or your
verbal request. Aggregate weights may change depending on gradations or specific gravity of material.
Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI.Any use or
dissemination without permission is a violation of federal criminal law.
COMMENTS:
&OM 1391 Wes.t. Mutkir:gbird Lane • C 1Lis.1exas 752.1,' • 972.64i,6TOO
txi.com
Date: 2/14/2013 Units: US
Mix Name: 8274 Mix Strength: 4,000 PSI at 28 Day!
STRENGTH SUMMARY, Compression 6" x 12"
Strengths
No. Of Avg Avg Avg 28 Avg Acc Accept Std ACI318
Tests Slump Air Day Age Age Dev Req'd
30 4.95 4.43 5310 5310 28 440 4590
DETAILED STRENGTH, Compression 6" x 12"
Plant Slump Air Strengths Acc Acc Age
28 Day Acc Age Age Run Avg 3
142 6.00 4.00 4960 4960 28
142 3.50 4.10 5550 5550 28
144 4.50 4.20 4980 4980 28 5160
140 4.50 3.20 5530 5530 28 5350
140 8.00 4.00 4670 4670 28 5060
140 4.75 4.00 5650 5650 28 5280
141 4.25 6.00 5380 5380 28 5230
143 4.50 4.50 6430 6430 28 5820
140 4.75 3.90 5080 5080 28 5630
140 4.25 3.80 5310 5310 28 5600
143 6.50 3.30 5120 5120 28 5170
128 4.00 4.50 5220 5220 28 5210
128 7.50 6.10 5130 5130 28 5160
150 5.00 4.50 5350 5350 28 5230
128 7.00 4490 4490 28 4990
128 7.50 5.80 4700 4700 28 4850
128 5.50 5.10 4940 4940 28 4710
128 5.00 4.10 5350 5350 28 5000
140 4.50 4.90 5200 5200 28 5160
128 3.50 4.50 5740 5740 28 5430
128 3.25 4.00 5830 5830 28 5590
128 5.00 5320 5320 28 5630
140 2.50 3.10 5630 5630 28 55'90
131 5.00 5.90 5240 5240 28 5390
131 5.25 3.40 6030 6030 28 5630
140 5.00 4.70 5070 5070 28 5450
122 4.00 4.30 5500 5500 28 5530
122 5.00 4.30 5020 5020 28 5200
122 4.00 4.90 4780 4780 28 5100
122 4.50 4.80 6060 6060 9a R9an
KRIU) MIDLOTHIAN CEMENT
245 Ward Road• Midlothian,TX 76065•972.775.3449•www.txi.com
e
SPECIFICATIONS
Portland Cement
Bin Number: Car Number: Tons: Type I/11(Low Alkali)
Sample Date: December-2012 Monthly Average A.S.T.M C150-11
-
Spec. Test Spec. Test
Chemical Requirements: Limit Result Physical Requirements: Limit Result
Si02, (%) A 20.2 Air Content,Volume, (%) 12 max 8
A1203,(%) 6.0 max 4.2 Average Fineness(Blaine), (m2/kg) 280 min 379
Fe203, (%) 6.0 max 3.4 420 max
CaO,(%) A 64.2 •
MgO, (%) 6.0 max 1.3 Autoclave Expansion, (%) 0.80 max -0.02
S03, (%) • 3.0 max 2.7
Loss on Ignition,(%) 3.0 max 2.1 Time of Setting:
Insoluble Residue,(%) 0.75 max 0.32 Vicat initial set;minutes 45 min 107
CO2, (%) A 1.2 375 max 107
Limestone, (%) 5.0 max 2.9
CaCO3 in limestone, (%) 70 min 95 Compressive strengths, (Mpa)
3 days 12.0 min 25.0
7 days 19.0 min 29.9
Potential phase composition, (%):B Compressive strengths,(psi)
C3S A 61 3 days 1740 min 3628
C2S A 12 7 days 2760 min 4411
C3A 8 Max 5
C4AF A 10
C3S+ 4.75(C3A) 100 max 87
Spec. Test
Optional Chemical Requirements: Limit Result
Total Alkalies(Na20 equiv.),(%) 0.60 max 0.57
A Not Applicable.
B Adjusted for limestone per A1.6
We Certify that the above described cement,at the time of shipment meets the chemical
and physical requirements of ASTM C-150 specification.
Signature: Date: 1/10/13
TXI corp.
i Bridgeport Stone Plant Technical Services Lab IV P.O. Box 487 Phone: 972-647-7232
• Bridgeport,Texas 76426 Fax: 972-647-7244
1111•111p11•v1111•1111•111Y111B11OW MIIM MINIMIIIIIMMIIM IIOiiN•a1111111111111ilii!l11111111111•Ia111111O1111111•Yn11111
DATE January 25,2013
COMPANY/NAME
MATERIAL Mfg Sand
1111N•111Y11•111111111•v11111•Y11111MIMMIMINEMEM ME a11N11MINuMIOHl UMIMIM MONi•I•I•I•IpININNI
TEST RESULTS
SIEVE SIZE WT.RETAINED %PASSING SPECIFICATION
U.S. METRIC
3/8" 9.5mm 0 100.0 100
#4 4.75mm 5.9 99.3 95 100
#8 2.36mm 166.2 80.3 80 100
#16 1.16mm 421 50.1 50 85
#30 .600mm 576.2 31.7 25 60
#50 .300mm 696.1 17.5 10 30
#100 .150mm 793.3 6.0 0 10
#200 .075mm 828.5 1.8 0 3
TOTAL WEIGHT 843.7 sample washed over#200
IIIIOEo11•l•11111•1111111M MI•I•MI111111O1111111111M INIIII MMWMI♦IIOI•II MMI•I•MMuOl111Ilo11111111111111o1111IIIIY11
SPECIFIC TEST RESULTS
TxDot 403-A Specific Gravity(SSD) 2.62 TxDot 411-A Magnesium Soundness 12
Sodium Soundness 1
TxDot 403-A Absorption 1.2
Unit Weight:
ASTM D 4791 Flat&Elongated N/A Dry Loose 99.7 LB./CF.
Dry Rodded 110.7 LB./CF.
TxDot 413-A Clay Lumps N/A
TxDot 203-F Sand Equivalent 82 Fineness Modulus 2.890
Ben Jones
Txi Representative
TX! corp.
•jrrj \ Bridgeport Stone Plant Technical Services Lab
�Al P.O. Box 487 Phone: 972-647-7232
Bridgeport,Texas 76426 Fax: 972-647-7244
Imam raanemommar muummu nmummu mtammnoonumnnmmmu u ususammu m n
DATE January 25,2013
COMPANY/NAME
MATERIAL 1" - #4 Class A
mumusnssuslllnsulmsuslnnssnlllllnsununlsulmnlsssllllslslllsnlII
TEST RESULTS
SIEVE SIZE WT.RETAINED %PASSING SPECIFICATION
U.S. METRIC
11/2" 37.5mm 0 100.0 100
1" 25.0mm 1.1 96.6 95 100
3/4" 19.0mm 7.6 76.7 (60 90)
1/2" 12.5mm 19.2 41.1 25 60
3/8" 9.5mm 24.5 24.8
#4 4.75mm 30.8 5.5 0 10
#8 2.36mm 32.3 0.9 0 5
TOTAL WEIGHT 32.6
Illausnssllusnllussssssll lssulllsulllssllnsull lsMIIMME ONNIMsulsllsuusl
SPECIFIC TEST RESULTS
TxDot 403-A Specific Gravity(SSD) 2.66 TxDot 411-A Magnesium Soundness 11
Sodium Soundness 0
TxDot 403-A Absorption 1
Unit Weight:
TxDot 410-A L A Abrasion 30 Dry Loose 97.2 LB./CF.
Dry Rodded 101.5 LB./CF.
TxDot 413-A Clay Lumps 0
TxDot 406-A Decantation 0.7
nIIllssussuIIMMIM lsslsIIMMIM IMI llWIIIINWIE IBIMIM 111 WIMIlsllsllnllsllllsniti
Ben Jones
Txi Representative
TXI corp.
bdTECHNICAL SERVICES LAB
TXI Concrete Sand PHONE: 972-647-7232
FAX: 972-647-7244
ummnsmumonsimmmummmuummismimwmaimmummInumummuommormumnimmu
DATE January 25,2013
COMPANY/NAME
MATERIAL Concrete Sand
11wMIIMEIMM1.111111111•Y••p••••n•rt i111noINIIIIMnOII®MIIM1111111 MMMMMY111n1Mt0o1111 n1•1111
TEST RESULTS
SIEVE SIZE WT.RETAINED %PASSING SPECIFICATION
U.S. METRIC
3/8" 9.5mm 0.0 100.0 100
#4 4.75mm 17.8 97.9 95 100
#8 2.36mm 86.3 89.8 80 100
#16 1.16mm 202.1 76.1 50 85
#30 .600mm 359.4 57.5 25 65
#50 .300mm 717.1 15.2 10 35
#100 .150mm 835.5 1.2 0 10
#200 .075mm 843.9 0.2 0 3
TOTAL WEIGHT 845.6 F.M. 2.623
UnZIn••n•un IMIIIY•O•••IIIIsnIIIIILllMnIn••IIn•n nMMIIII•n•nnMnIIIIIIIIIIMiIInIIMIIIIIIIi®nnIItY11I•1
SPECIFIC TEST RESULTS
TxDot 403-A TxDot 403-A Specific Gravity(SSD) 2.63 TxDot 411-A Magnesium Soundness 8
Sodium Soundness 1
TxDot 403-A TxDot 403-A Absorption 0.5
Unit Weight:
TxDot 612-J TxDOT 612-J Acid Insoluble Residue 83 Dry Loose 103.2 LB./CF.
Dry Rodded 110.2 LB./CF.
TxDot 203-F TxDot 203-F Sand Equivalent 90
TxDot 413-A Deleterious Materials 0%
1 nn \M 1111111M•1f1111ntMIIInAIInMMMMMO111i.• III
Ben Jones
TXI REPRESENTATIVE
BASF
The Chemical Company
January 2,2013
TXI Operations, LP
1341 W. Mockingbird Lane
Dallas,Texas 75247
Attention: Victor Villarreal
Project:All Projects
Project location: Various Locations
Certificate of Conformance
MB-AETM' 90
BASF Corporation*Air-Entraining Admixture for Concrete
*(successor in interest to BASF Construction Chemicals, LLC,which is successor by merger to BASF Admixtures,
Inc.,formerly known as Degussa Admixtures, Inc.,formerly known as Master Builders, Inc.)
I, Richard Hubbard,Sr.Technical Marketing Specialist for BASF Corporation,Cleveland,Ohio,certify:
That MB-AE 90 is a BASF Corporation Air-Entraining Admixture for concrete; and
That no calcium chloride or chloride based ingredient is used in the manufacture of MB-AE 90;and
That MB-AE 90,based on the chlorides originating from all the ingredients used in its manufacture,contributes less
than 0.000068 percent(0.68 ppm)chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg
(1 fluid ounce per 100 pounds)of cement;and
That MB-AE 90 meets the requirements of ASTM C 260,Corps of Engineers'CRD-C 13 and AASHTO M154, the
Standard Specifications for Air-Entraining Admixtures for Concrete.
Richard Hubbard
Sr.Technical Marketing Specialist, BASF Corporation
RACE Cnrnnrft4inn
si BASF
The Chemical Company
January 2,2013
TX?Operations, LP
1341 W. Mockingbird Lane
Dallas,Texas 75247
Attention: Victor Villarreal
Project: All Projects
Project location:Various Locations
Certificate of Conformance
Pozzolith®100 XR
BASF Corporation*Admixture for Concrete
*(successor in interest to BASF Construction Chemicals, LLC,which is successor by merger to BASF Admixtures,
Inc.,formerly known as Degussa Admixtures, Inc.,formerly known as Master Builders, Inc.)
I, Richard Hubbard,Sr.Technical Marketing Specialist for BASF Corporation,Cleveland,Ohio,certify:
That Pozzolith 100 XR is a BASF Corporation Set Retarding Admixture for concrete; and
That no calcium chloride or chloride based ingredient is used in the manufacture of Pozzolith 100 XR;and
That Pozzolith 100 XR, based on the chlorides originating from all the ingredients used in its manufacture,
contributes less than 0.00014 percent(1.4 ppm)chloride ions by weight of the cement when used at the rate of 65
mL per 100 kg(1 fluid ounce per 100 pounds)of cement;and
That Pozzolith 100 XR meets the requirements for a Type B, Retarding and Type D,Water-Reducing and Retarding
Admixture specified in ASTM C 494,Corps of Engineers'CRD-C 87 and AASHTO M194,the Standard
Specifications for Chemical Admixtures for Concrete.
. , J(,-,A
Richard Hubbard
Sr.Technical Marketing Specialist, BASF Corporation
BASF Corporation tr s
a IN BASF
The Chemical Company
January 2,2013
TXI Operations, LP
1341 W. Mockingbird Lane
Dallas,Texas 75247
Attention: Victor Villarreal
Project:All Projects
Project location: Various Locations
Certificate of Conformance
Pozzolith®200 N
BASF Corporation*Admixture for Concrete
*(successor in interest to BASF Construction Chemicals, LLC,which is successor by merger to BASF Admixtures,
Inc.,formerly known as Degussa Admixtures, Inc.,formerly known as Master Builders, Inc.)
I, Richard Hubbard, Sr.Technical Marketing Specialist for BASF Corporation, Cleveland,Ohio,certify:
That Pozzolith 200 N is a BASF Corporation Water-Reducing Admixture for concrete;and
That no calcium chloride or chloride based ingredient is used in the manufacture of Pozzolith 200 N;and
That Pozzolith 200 N,based on the chlorides originating from all the ingredients used in its manufacture,contributes
less than 0.00013 percent(1.3 ppm)chloride ions by weight of the cement when used at the rate of 65 mL per 100
kg(1 fluid ounce per 100 pounds)of cement;and
That,depending on the dosage used, Pozzolith 200 N meets the requirements for a Type A,Water-Reducing,Type
B, Retarding,and Type D,Water Reducing and Retarding Admixture as specified in ASTM C 494,Corps of
Engineers'CRD-C 87 and AASHTO M194,the Standard Specifications for Chemical Admixtures for Concrete.
Richard Hubbard
Sr.Technical Marketing Specialist, BASF Corporation
BASF Corporation Ar--A_- -