Tax 2011B-LR130218GEOTKHnlCflL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 02/15/2013 Report Date: 02/18/2013 Sampled By: Godwin, Jonathan Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: Southbound Heartz Rd. at Van Bebber Dr. intersection, Sampled: Order Number: 1770 South of the northern most leave out (for colored concrete) on southbound Heartz Rd. Spec Age Tested Nbr (date : days) A 02/18/13:3 B 02/22/13:7 C 03/15/13:28 D 03/15/13:28 Compressive Number of Diameter Client: City of Coppell Specimens: 4 REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 142429 Material: Concrete Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 142429 Type 4 Type 5 Page 1 of 1 Spec Age Tested Nbr (date : days) A 02/18/13:3 B 02/22/13:7 C 03/15/13:28 D 03/15/13:28 Specification Strength: Slump: 3 -5 Air Content: 3 -6 Compressive Maximum Diameter Area Load (in) (in2) (Ibs) Break Type 6.00 28.27 109,270 Type 2 6.00 28.27 6.00 28.27 6.00 28.27 Type 4 Type 5 Type 6 Type 1 Type 2 Type 3 Specification Strength: Slump: 3 -5 Air Content: 3 -6 Slump: 4.0 Inches Air Content: 5.4% Mix Code: 8274 Date Received: 02/16/2013 Curing Method: Standard Time Sampled: 2:20 pm Time Batched: 1:34 pm Temp.: Ambient: 47 °F Mix: 58 °F Unit Weight: 148.3 # /cu ft Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 50 cu. yd. total placement Remarks: Transported By: TXI Source /Sampled At: Truck / Center Plant: 143 Truck/Ticket No: 8025 / 1607421 Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Ka ara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Compressive Average Cure Strength Strength Tested Loc (PSI) (PSI) By Comments Lab 3,860 3,860 Lab Lab Lab Type 4 Type 5 Type 6 Slump: 4.0 Inches Air Content: 5.4% Mix Code: 8274 Date Received: 02/16/2013 Curing Method: Standard Time Sampled: 2:20 pm Time Batched: 1:34 pm Temp.: Ambient: 47 °F Mix: 58 °F Unit Weight: 148.3 # /cu ft Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 50 cu. yd. total placement Remarks: Transported By: TXI Source /Sampled At: Truck / Center Plant: 143 Truck/Ticket No: 8025 / 1607421 Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Ka ara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.