Loading...
Shake & Shingle 3-SP130221 TRANSMITTAL P� � i g c i 2 gross design group, incorporated 2 �® 5310 Harvest Hill Road,Suite 180 Dallas,Texas 75230 972-759-1409x. ,IrAllIF 2 I /• To: Mr. Pete Hennessey Date: /02/18/13 Hennessey Engineering, Inc. Jo• g; 1243 1417 W. Main Street, #100 Project: Ingle's Phase III Carrollton, TX 75006 (P) 972-245-9478 Location: Coppell, Texas Material Sent Via: Fax X Our Messenger/Zip Mail Your Messenger Other: Make Corrections Noted Rejected As You Requested 1. Review and Comment For Resubmittal For Your File © For Approve For Construction For Your Signature EC No Exceptio`e For Your Job Use Other: r Copies Submittal# Description Comments 3 02500.01 Underground Utilities Product Data Remarks: Submitted By: -- CC: File Mark W. Pross/Imp Teir-, //6/1/1-161/- 7(9 912 2 1 9� ., , 1 1 1 II RATCLIFF CONSTRUCTORS, LP 4200 Beltway Drive, Addison, Texas 75001 PHONE 972-432-9969 FAX 972-432-9943 LETTER OF TRANSMITTAL February 12, 2013 Mr. Mark Pross Pross Design Group Inc. 5310 Harvest Hill Road, Suite 180 Dallas,TX 75230- FEB 1 5 2013 RE: Ingle Office Warehouse Phase III,Building 10 200 E. Beltline Rd. Coppell,TX 75019- We are sending you: [X] Enclosed [ ] Contracts [ ] Prints [ ] Plans [ ] Copy of Letter [ ] Change Order [ ] Specifications [ ] Other Copies Date Other Description 3 2/12/13 02500.01 Underground Utilities—Product Data These are transmitted as checked below: [ ] For Your Use [ ] Reviewed;No Exception Taken [ ] As Requested [ ] Make Corrections Noted [X ] For Approval [ ] Amend and Resubmit [ ] Rejected; Resubmit RATCLIFF CONSTRUCTORS,LP /' 4Y. Marti. Project Manager FORTILINE WATERWORKS Dallas Underground, LLC Shake and Shingle Coppell, Tx. RATCLIFF " CONSTRUCTORS, INC. SUBMITTAL NO: 02.510. I CK'D: ESE DATE: REVIEW OF TH SHOP DRAWINGS BY THIS CONTRACTOR DOES NOT RELIEVE SUBCONTRACTORS ,OR VENDORS OF RESPONSIBILITY FOR CORRECTNESS OF DIMENSIONS,QUANTITIES OF MATERIALS OR ,COMPUANCE WITH CONTRACT DOCUMENTS., Please find Fortiline Waterworks submittal package for the above referenced project. This package contains information on the following materials: Water K 4Diamond Plastics AWWA C900 DR14 PVC Pipe for Water Lines (4"-12")rg Mueller Series A423 NST Fire Hydrant 5'-0" /*Mueller Series A2360 RW Open Left Gate Valves (2"-14") (. ' *Tyler Pipe Series 562 Valve Boxes • *Ford Series 1500 M/J Restraints (Megalug) . *Tyler Pipe Series C110 Full Bodied Ductile Iron Fittings • *Ames Series Stainless Steel In Building Fire Riser • *Cerro Flow Products Series Type "K" Copper Service Tubing i *Croker Series Fire Department Connection 90 Sewer *Diamond Plastics AWWA SDR35 Gravity Sewer Pipe (4:-15") *Plastic Trends Series SDR35 PVC Sewer Fittings *PW Eagle Series Waste Water Access Chamber✓ Storm %/Johnson County Pipe Series Class III RCP tk k1*1A-LL - l$" ID. 1-te4141-1- - -nrf-RAJeft- 0KPr� Thank you, Sean Stilley DFW Sales Representative Fortiline Waterworks C900: PVC Pressure Pipe - Y SPECIFICATION DATA ��� Diamond (C900) PVC Pipe (4"through 12") 4 �� _ is made of 12454 compound per ASTM r . Imo,"- ,`. :, , D1784,in accordance with the dimensional, 5 chemical,and physical requirements of fir" AWWA C900. Diamond (C900) PVC Pipe bears the mark of NSF,International (NSF),the listing of s �# Underwriters Laboratory,Inc.(UL),and `e (DR14& DR18) bears the listing of Factory Mutual(FM). �• _ "' per. ` �1 d.* 4 Diamond (C900) PVC Pipe utilizes a gasket, a ,� per ASTM F477,to seal the integral bell socket to the spigot of the next joint(which conforms vs , " to the requirements of ASTM D3139.) Each ° ° _. . , . .= male end is beveled to facilitate joint assembly, and the spigot is referenced marked to ensure proper insertion depth.Diamond furnished lubricant is to be used in the joining process. Factory Mutual Systems APPROVED Physical Properties of PVC 12454: Property ASTM Minimum k`' Test Ili; ` Specific Gravity D792 1.40 Tensile Strength,psi D638 7,000 Tensile Modulus,psi D638 400,000 IZOD Impact Strength D256 .65ft.,lb./in. Underwriter Laboratories Inc.© SHORT FORM Specification for Diamond C900 PVC Water Pipe Diamond C900 PVC Water Pipe shall be made of compounds conforming to ASTM D1784 with a cell classification of 12454.Diamond C900 shall meet all the dimensional,chemical,and physical requirements as outlined in AWWA C900 and will be supplied in 20 foot laying lengths.Joints shall meet the requirements of ASTM D3139 and shall be formed using Rieber Technology.Gaskets shall meet the requirements of ASTM F477. Potable water pipe shall be manufactured from National Sanitation Foundation(NSF)approved compounds. DIAMOND PLASTICS® 111111,11 Corporate Headquarters• 1212Johnstown Road•P.O.Box 1608•Grand lsland,NE68802-1608 Inge:�.six E M- Nia .a y 4 A Reiber Joint Illustration D- 01 A < ( C ' � o - i�? I�;i Extreme Testing c o,dtt c.r,s gC900 PVC pressure pipe,available m E.:- L sy pressure ratings for a wide range of water C ,. transfer applications(Available in sizes _ ' from 4"through 12") • T`i 1 ` 'TWA [ Q 'off AWWA C900 SPECIFICATION DATA + � r.. Tough a�?'tk r 1 ""'t'` t ce` w" #� t ",.s:�. ', '. ",,fi z ■.x`'* 4 ,z i ,. �� iina 1� tamer' `3eli Diameter Apipro�t+ S �t �� ? A la e �4R 25`° ,may Pi k a ", T, (B` Bell Depth C � � 1' Minimum. if Minimum )' Niinimu m She t Inches � Inches Mar Wald t(.W441(t) Waif ft) �. �� �,�,�`3, ��a,�"4.,3e �..tin As-,.�:y t �xw w�, .,s�. d x . _,. �#�s� '�A? -.'td'�+..i�: "� „c '+^� ' y t 1%w't�aw ,.ff°i,+' `, ,°zks.^s ll'ixw%n^r.:A a rwr arr ,,. ..x...«_...,uss :.. ......rx.ss r ?.ahem;a; ;s xr . ,nn :r 4"(100) 4.800 (121.9) 6-1/2" 6 5 0.343 (8.71) 0.267 (6.78) 0.192 (4.88) / 6"(150) 6.900 (175.3) 9 1/4" 6.5 6 0.493 (12.52) 0.383 (9.73) 0.276 (7.01) ✓ 8"(200) 9.050 (229.9) 11-3/4" 7 6.5 0.646 (16.41) 0.503 (12.78) 0.362 (9.19) 10"(250) 11.100 (281.9) 14-1/4" 7.5 7 0.793 (20.14) 0.617 (15.67) 0.444 (11.28) 12" (300) 13.200 (335.3) 16-3/4" 8 7.5 0.943 (23.95) 0.733 (18.62) 0.528 (13.41) "Possession of this page does not constitute an offer of sale" DIAMOND PLASTICS® Corporate Headquarters• 1212 Johnstown Road• P.O.Box 1608•Grand Island,NE 68802-1608 s c r ^��.. r ,`� � �� � � �r'� i 'r a " x .a 1 z ,,.: . : ?a,ra., °.,� ,,� ' " a ? t ',. � �� <g s r` , •. _ . ... . . ..... . ..Mueller® Super en.... .. „ Centurion 250TM w . , ,. ... .,,..,.. .. H drant,.., ..., . . . ...„,, ,.. . ... . . q ...... „ „ ‘ - ..spa a , E � ' - 0 ip, 1 ?all ,.„, ....;- . ;,:iiitt ' , . +ate ,. _ ___ ,fix 1 6 .,,,,,...... , . i . .. ,, 77 ill 5 f f� pr, • 1 x r 44 y 2 r 5 "A � n n�'.• -':.--;,''' ,, ' &ii,itk I,:'P.'',r -'k, ''Ai.'f r'i'' ,,, „. I. . i � '}} tr e P - `rK a s i i.. „.... . 1 �, ,,g/ 1,,i- i � f * '1l Ptw .4' ' ¢t x•`......,,,;.„..:,..,„...1- ti x A � '{ 4 4 1 y t.YrA TJ„$"+r Muollor Co. Mueller® Super Centurion 250TM Fire Hydrant...250 psig rating, high flow, dependable performance, 10-year limited warranty...and convenient, reversible main valve Performance is the real test of a fire hydrant. Proven flow characteristics, 250 psig rating,and easy operation and maintenance are among the features of the Mueller®Super Centurion 250"''3-Way Fire Hydrant. Plus,the hydrant is backed by a 10-year limited warranty on materials and workmanship,and our plant is ISO 9001 certified,the highest level available. ® 250 psig working pressure;500 psig test pressure. Convenient,reversible main valve doubles service life. Advanced safety coupling and flange design reduce traffic 1 damage to hydrant. Convenient replacement kit available. r ® Stainless steel safety stem coupling resists corrosion and assures a tight connection between stem sections. ® Efficient hydraulic design provides maximum flow. C'.. ® Hose and pumper nozzles are threaded in and field-replaceable. ® Forced lubrication system and anti-friction washer ease operation. "" ▪ Main valve is easily removed from either the bonnet flange or ground line flange. ▪ Fully conforms to AWWA Standard C502 Underwriters Laboratories Listed • Factory Mutual Approved 1y From bonnet to shoe, performance is built in Dry-top design, with unique, self-oiling system, depressed by a vehicle tire,and the main valve remains provides automatic,positive lubrication for easy closed.Service is restored quickly and easily without operation,even after years of service. Lubricant excavation by replacing the safety flange and coupling is forced over all stem threads and bearing surfaces using a convenient repair kit. in the operating mechanism each time the hydrant is operated.Dual 0-ring seals prevent lubricant loss during Reversible,compression- s shipping, storage or type main valve closes with Li c installation and keep water water pressure for positive r away from stern threads and sealing.Double dram valves N m i 1 bearing surfaces when the are force flushed each time it s hydrant is in use An anti- the hydrant is operated and - - friction washer and automatic provide drainage of the lubrication of the thrust collar barrel.A special wrench allows removal of the main 11110 , . _ . : , ,,,, ,,1 add to easy operation. valve and seat ring from either bonnet or ground level flange,The main valve is made of durable robber which provides a long service life,yet is reversible,providing " d" a convenient spare in place. Hose and pumper nozzles are threaded-in for easy field replacement if damaged,or for Shoe is designed for maximum flow and easy changeover to different thread style.A special connection with its smooth transitional contours, locking method makes extended neck and integral installation simple and anti-rotation pads,allowing """, t use of standard tee-head secure.The nozzles can be faced in any .. ■ •ik, bolts.The shoe also has ' � large blocking pads for direction by loosening i` • �; k the safety flange bolts c, . . easier setting and two lugs N and rotating the upper for strapping.(Strapping lugs barrel assembly. are not provided on flanged i. connections.)The inside `" of the shoe is covered with Improved safety flange and stainless steel .. Mueller HP®Epoxy Coating. stem coupling perform more predictably to protect The drain ring housing, the main connection from traffic induced damage lower main valve plate and its retaining nut and minimize damage to the hydrant. If struck by are also covered with epoxy.This a vehicle,the safety flange breaks away below the thermosetting epoxy forms a tough, ground flange area and the safety stem coupling pulls corrosion-resistant barrier to chemicals, apart.No loose pieces can fall into the lower barrel physical impact and electrical currents. where they could affect main valve or drain operation. The high strength stainless steel 0-ring sealed flanges at the bonnet, " safety coupling resists corrosion ground line and shoe simplify and assures a tight connection maintenance by eliminating gasket 4: etween the stem sections during adhesion at these points,making normal hydrant operation.Upon disassembly easier.The 0-rings are traffic impact,the coupling tears than flat gaskets to position away,leaving the lower stem below during reassembly,and provide ground level where it cannot be superior pressure handling. 1 Hold-down nut-features integral weather seal. Prevents unauthorized removal of hold-down nut or bronze operating nut. `t Resilient wiper seal prevents water entry and protects from freezing;material resistant "` �] to sunlight deterioration.0-ring provides e �. second level seal. 2 Anti-friction washer-helps assure easy °' �"� � operation over life of hydrant. �� 3 Oil filler plug-permits visual check of oil level. Allows addition of oil without -= ti 0 t L _ removing bonnet. 4 Sealed oil reservoir-0-ring sealed to Prevent leakage. Lubricant is forced over . stem threads and bearing surfaces each time hydrant is operated. 5 Dual 0-ring seals-seal in lubricant; I 5 seal out water. '; c, r, 6 Field-replaceable hose and pumper 6 nozzles-0-ring sealed;threaded in place and retained by stainless steel locks. t' • ' : .: ') ' .1 ' 44 7 Full flow openings—large,smooth \.,,,, radius hose and pumper openings reduce friction loss. . 8 Heavy-duty,non-kinking chains— ;.:'.�� `; special chain loop permits free turning " . �' `r. ; of cap. 1 9 Stainless steel safety stem coupling—provides a tight,corrosion resistant connection during normal operation.If vehicle hits hydrant,coupling pulls ' ^+ free without breaking into pieces,preventing stem or main valve damage.Designed so a tire cannot '�w. ;�. - depress stem and open main valve. ' 10 Zinc-plated bolts and nuts—protect against corrosion. 11 Safety flange—breaks cleanly to help prevent barrel damage,but strong enough to withstand normal handling.Allows 1. economical repair,adding of extension section,rotation or changing of upper x, barrel without excavation. doh . 17 250 psig working pressure rating- compatible with today's trend toward higher pressure system components. f 12 Drain valve facings—specially 4, designed,long-life plastic facings provide effective sealing. 13 Bronze upper valve plate-conical design reduces turbulence. 14 Bronze seat ring-threaded into bronze drain ring and 0-ring sealed.Can be removed , or installed from above ground. Double drain valves force-flush drain openings to keep them open for effective barrel drainage.Bronze drain valves are integral parts of main valve assembly. 15 Reversible,compression-type main valve- .r closes with pressure for positive seal.Rubber material has long service life,yet is reversible, # providing a convenient spare in place. 12 16 Cap nut—retains main valve. Sealed by cap nut gasket to prevent corrosion of stem threads. - 17' Locked in place by a stainless steel lock washer. 6 Epoxy coated to resist corrosion. 17 U-ring flange seals-superior pressure 3::::11,:',,,: "' �� handling,easier disassembly and maintenance. Contoured shoe-designed for „ maximum flow.Extended neck and " '► anti-rotation pads allow use of standard .- 6 tee-head bolts. Mueller HP®Epoxy Coating- covers shoe interior,main valve lower .a plate and its retaining cap nut.Drain ring housing is also covered to resist Iv corrosion and deposits, and ease main valve removal. Main valve operation -ILI 1—i j . -INLIII li,j-- l' 1!— -L- 1 4AELICL Closed—main valve Opening—water Fully open—main Closing—water Fully closed—drain held closed by operating pressure force-flushes valve guides seal drain pressure again force- valves are open to allow nut and water pressure; double drain valves valves closed. flushes drain valves. drainage of barrel. barrel is dry. and drain openings; establishes drainage field around hydrant. r® Centurion® Fire Hydrant ,% Mueller® Y1 ; 250 psig working pressure—500 psig test pressure Hydrant '414- �epair kits A-421 4-1l2" three-way 2 hose nozzles and 1 pumper nozzle Having everything you need A-423 5-1/4" three-way 2 hose nozzles and 1 pumper nozzle in a convenient kit helps 200 psig working pressure—400 psig test pressure make routine maintenance easier and periodich hydrant -®- (Many of the same features as the Centurion 250"''hydrant) periodic Y ,.r.�, upgrading simpler.Kits o A-420 4-1/2" two-way 2 hose nozzles are available for five 5 A-422 5-1/4" two-way 2 hose nozzles — different hydrant sections. A-424 4-1/2" one-way 1 pumper nozzle Specific kits include: A-425 5-1/4" two-way 2 pumper nozzles "Gi"' t Storz pumper nozzle option— Wi Th Bonnet repair kit fan' Weather seal. Hold-down nut 0-ring. •Available for 5"pumper nozzles,an integral storz connection a Bonnet 0-ring. Anti-friction washer. allows the fire department to connect its pumper hose to the `' Stern 0-rings. hydrant with a quick,quarter-turn action. Bonnet flange 0-ring and gaskets •No thread alignment,cross threading or leakage problems. = Hydrant lubricating oil. 4-way with monitor elbow— :r�, •Monitor style eliminates a possible leak path with separate i Safety flange repair kit monitor nozzle attachment. a Stem coupling. Safety flange. •All parts interchangeable with Mueller Super Centurion Flange gasket. Hydrant lubricating oil. 250 hydrant. Replacement bolts and nuts. •250 psi working pressure;500 psi test pressure. R ,e rf Bonnet flange 0-ring and gasket t� •Full flow 4-way openings:4"monitor elbow,one 4-1/2" = i Extension kit pumper nozzle,two 2-1/2"hose nozzles. Extension barrel. Extension stem. •: Flange. 8 bolts and nuts. Sizes and types of inlet connections Flange 0-ring and gasket.t Size of Aqua-Gripml Mech. D-150 Mech. Hydrant lubricating oil. Hydrant System IPS/DIPS Flanged* Joint Joint Slip-On Stern coupling and hardware. 4-1/2" 6"" 4" G' 4" 6" 8" 4" 6" 6 Bonnet flange 0-ring and gasket.t 5-1/4" 6..,. 4.. 6.. il (Auxiliary gate valves with flanged outlet and choice of inlet can be attached to hydrant with flanged inlet.) S Main valve kit *Available with vertical or horizontal inlet. Top seat 0-rings. Lower valve plater **Two styles available:IPS(PVC,PE,steel)or DIPS(DI,PVC,PE). Bottom seat 0-rings. Cap nut seal. Main valve:lt Lock washer. Bronze seat ring. Mueller accessories A-359-00 seat wrench— «_': A-367 brass sleeve— e!Shoe repair kit remove fit;used to when protects h bonnet from damage Drain valve facings. Cap nut seal. remove main valve and when the bonnet is removed Top seat 0-ring. Main valve. seat ring from bonnet level from the upper stem. or ground line.Wrench Lower valve plate.t Lock washer. self-centers on barrel flanges. Bottom seat 0-ring. Shoe nuts and bolts. Drain valve facing screws. A-311 operating wrench— A-51 hydrant lubricating Drain ring housing 0-ring and gasket. operates nozzle caps,pin oil we 10.5 oz.can of Hydrant lubricating oil. and lug-type hose couplings, all-weather oil exactly hydrant operating and fills oil reservoir. 4- hold d0 vn nuts. -_ Kit includes both 0-ring and gasket to accommodate either •!.z.: ' 250 psig or 200 psig style hydrants. Ordering hydrants,accessories,or repair kits t tReversible style main valve and lower valve plate—must For complete ordering information refer to the Mueller Water Distribution Products Catalog(available on-line). be used together when replacing non-reversible style parts. Manufactured under one or more of the following: te- U.S.Patent No.4,717,178:4,842,246. Mueller Comj Main Office—Decatur,IL Water Division: 1-800-423-1323 Canada—Mueller Canada Inc.,Milton,Ontario 1-905-878-0541 www.muellercompany.com e-mail:moreinfo @muellercompany.com All products must be installed and maintained in accordance with applicable instructions and/or standards. Form lO818-P.cv.1 0/05-20M-1 Copyright 1995 Mueller Co. Printed in U.S.A. MUELLER' 2360 SERIES TIM Mueller Co. 10 ® 1 RESILIENT WEDGE GATE VALVE Rev.12-12 Shaded area indicates change. MUELLER®2300 Series Resilient Wedge Gate Valves Mueller®Resilient Wedge Gate Valves have features to make them easier to operate and to preserve the sealing capability and interior coating integrity for many years of reliable service. In addition to popular end connection options,Mueller brand RW valves can be ordered with Mueller's exclusive Aqua-Grip`" System that incorporates an 0-ring sealed compression connection and integral pipe restraint in one"ready to use"easy and quick to install package. Mueller 2" — 12" 2360 Series Resilient Wedge Gate Valve Features pr <-`•``' ❑ SMOOTH,OVERSIZED FLOW WAY ❑ TRIPLE 0-RING SEALS PLUS DIRT .?x��,, SEAL-two above thrust collar and nsdsa' -full,round,unobstructed flow way one below,retain lubricant in this criti- , accommodates full size cutters,provides cal area. Top two are replaceable with _„,-,43-7,---,-. " superior flow characteristics and reduces valve fully open and under pressure. ,.�,;j, ' pumping costs.** Fourth seal at top serves as dirt seal$. r `4 ❑ MUELLER'PRO-GARD"FUSION ❑ TWO ANTI-FRICTION WASHERS EPDXY COATING-10 mils*thick WITH LUBRICATION-made of ', k, protects all inside and outside iron sur- polymer,one above and one below the ". faces,and complies with AWWA C550 thrust collar,reduce operating torque a S,,--.e• c e' -7 and certified to ANSI/NSF 61. to open or close valve. 41,-."` ❑ 250 PSIG MAXIMUM WORKING ❑ STEM-forged manganese bronze bar ! r at j - 1 - PRESSURE-Hydrostatically tested stock is upset,then machined to form is` s*„ a at 500 psig. Surpasses ANSI/AWWA a thrust collar for superior strength in N'Tfer2,- ° Standard C509 by 25%. UL/FM:200 r r >, a 4' psig MWP.*** this critical area, p g .� - ❑ WEDGE-cast iron,fully encapsu- 'tea.„r r e:- 1 ❑ AMERICAN MADE QUALITY- lated in molded rubber-no exposed �= = factory in Chattanooga,TN with ISO iron. r 9001:2000 certification,and UL 262, v Ii� I FM 1120/1130. Certified to ANSI/NSF ❑ EXTENDED WEDGE GUIDES- r �f x . 61. Manufactured and tested in compli- molded as part of wedge,ride inside s ' y r ante with ANSVAWWA Standard C509. body channels to maintain wedge f; t UL Listed and FM Approved. alignment throughout its travel. ,;:."- r, r x 'I in, ' r� ❑ BI-DIRECTIONALFLOW ❑ GUIDE CAP BEARINGS made ' of polymer and snapped over rubber � ," i ❑ FLAT BOTTOM SURFACES-stands covered wedge guides,provide bearing „e"-',,,* :;., r ,e s ,�a -f '" 4 y . upright for easier handling and storage. surfaces that protect both wedge and ,�}" ', a p': n .) 114 ❑ 10-YEAR LIMITED WARRANTY- interior body coating from wear and � � r �E n 6 tl�° aid in easy operation-even the largest ,t1,4,."...`" -".0,3;,,r.; _ n -ter is I` assured reliability(see separate Mueller y p ; k� 4 i . ' Warranty document for terms). valves installed horizontally.Rollers, ; � ����z �:" x t� ,�>�` t.rt1 t ...I E i tracks or scrapers are not needed. r" ) 4 i 'i ]y 'La'' j., '1:,:,,,i.:1*:"; 4... 3 �, `�,S Y:#.. J t. y i V '''?'':' q±',X; ''''411 .14..11. ri Mueller 14" -54" 2361 Series Resilient Wedge Gate Valve Features In addition to all the features of the smaller 2360 series valves,large size Mueller 2361 series RW valves offer these features: Cl STEM-Manganese bronze casting with ❑ LISTINGS AND WORKING PRESSURE- integral thrust collar. All valves are certified to ANSI/NSF 61 and shell tested to 500 psi. `-,i SIZE AWWA C515 UL FM LI WEDGE-Ductile iron,fully encapsulated in e,,,,„':;!"..'-',:'* WORKING WORKING WORKING molded rubber. r PRESSURE PRESSURE PRESSURE 14"-16" 250 250 250 ❑ BODY AND BONNET-Ductile iron. _ 18"-24" 250 175 ttt 1 30'-4W 250 if ttt t' 4,, t 2, . 54 250t it tit ..k* . � tAWWAG15 does not recognise valves larger than 48" *Nominal \ate k` i t UL does not list valves with gating(gearing required on vsirca 30"and larger) **16"valve requires 1/2"undersized cutter fit FM does not approve t alvcs larger than 16" ***250 psi UL/FM rating available as an option. 4. y Wirt seal on 4"-12"valves. Double-Disc Style gate valves follow the RW valve pages. 29U 4-77 :11z: `-11 141 Ic 1:;11 .1 k k'qjkz•, r4 n "‘ MEtIk Nag, ta [ 11 CAST IRON SERVICE & VALVE BOXES iRov]: ASTM A-48 (Minimum tensile of 21 ,000 PSI) WALL: Minimum1/4" thickness WEIGHT: Minimum 60 pounds EXTENSION: Minimum 19" to 22" SHAFT: Minimum 51/4" diameter HD WEIGHT: Minimum 13 pounds WHEEL OAD:Meets requirements of AASHTO H20 ;31.15 Th Tyler Pipe/Utilities Division PO. Box 2027 Tyler,Texas 75710 (903) 882-5511 I ;1 Union Foundry Company PO. Box 309 Anniston,Alabama 36202 (256) 236-7901 SUBMITTAL INFORMATION =N �;`_ Ifni-Flange Retainer (UFR1500-xA-1 style) ,_ �- 3" -12" UNI-FLANGE SERIES 1500 FOR C900 AND IPS PVC PIPE -WITH ACCESSORIES Ductile iron actuating screw,with the U.S.Patent No.6,322,273 Safety stop insures ring segments can SO-EZT"gasket-sizes Auto-Tork break-away head design, 1111 never be over-tightened. 4"-12"(ANSI/NSF Standard insures proper torque during installation. uii 61 approved,3"provided Auto-York Bolt with mechanical joint transi- O�- 0 /tion gasket) ♦ / it . Ale, A ilk 1 I Ij;f MI Restraint Segment 1 W®gI ✓i� 15x',,r,1% r (9k `'(=,,,i.... la To •,,,. iirolf, 4. Si T.,, WA. • ■��. ��. Bolt Hole Cross Section Front n„ Back Gland body is of High Strength Ductile Iron per 101 Ring Segments are ductile iron per High strength,low alloy T-bolts& ASTM A536,Grade 65-45-12. Compatible with all ASTM A536 and heat treated to a nuts (AVWVA C111) mechanical joints conforming to ANSI/AVVVVA C111 /A21.11. hardness of 370 BHN minimum. PRESSURE RATING ✓SUBMITTED NOM. CATALOG No.OF APPROX. P2�• ITEM(S) PIPE 0.D. NUMBER RESTRAINT WEIGHT P1` BC D C900 ASTM D2241 SIZE SEGMENTS (LBS.) C900 IPS DR-18 DR-14 SDR-26 SDR-21 3" 3.50" UFR1500-3A-I 4 9 11.50" 9.00" 6.19" 4.06" 160 PSI 200 PSI 4" 4.50"-4.80" UFR1500-4A-I 4 10 13.00" 9.40" 9.25" 7.50" 4.90" 150 PSI 200 PSI 160 PSI 200 PSI 6" 6.63"-6.90" UFR1500-6A-I 6 14 15.13" 11.60" 11.65" 9.50" 7.00" 150 PSI 200 PSI 160 PSI 200 PSI 8" 8.63"-9.05" UFR1500-8A-I 6 18 17.25" 13.75" 13.60" ' 11.75" 9.15" 150 PSI 200 PSI 160 PSI 200 PSI 10" 10.75"-11.10" UFR1500-10A-I 8 25 19.38" 16.00" 15.85" 14.00" 11.20" 150 PSI 200 PSI 160 PSI 200 PSI 12" 12.75"-13.20" UFR1500-12A-I 8 29 21.50" 18.05" 17.85" 16.25" 13.30" 150 PSI 200 PSI 160 PSI 200 PSI *Maximum O.D.of gland on pipe before Auto-Tork heads are removed(as shipped). **Maximum O.D.of gland on pipe after Auto-Tork heads are removed. FEATURES • Can be used with any thickness class of AWWA C900 PVC or ASTM D2241 IPS PVC without modifying the Auto-Tork bolts. • Full circle contact and support of the pipe wall. • "Auto-Tork" actuating screws with heads specially designed to twist off at the correct installation torque, leaving a hex head in case future system maintenance or removal is required. o Restraining segments are mechanically retained in pockets. • Series 1500 eliminates the need to pour expensive and time consuming concrete thrust blocks. • UL/FM approved, 4"-12" nominal size C900 PVC, for use on listed and approved PVC pipe. • Shrink-wrapped in a weather-resistant carton. • Imported ductile iron castings. o Assembled, inspected and packaged in the U.S.A. The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications,are subject to change without notice. Please verify that your product information is current. The Ford Meter Box Company, Inc. Submitted By: .1 r r 1 P.O. Box 443,Wabash, Indiana U.S.A.46992-0443 `1-. Phone: 260-563-3171 / Fax: 800-826-3487 "' Overseas Fax:260-563-0167 http://www.fordmeterbox.com 03/14/08 22U o Mechanical Joint AWWA Cl 1 ®/A21 .10 TYLER UNION' Full Body Revised 08/11 r ` is 2" through 48" ..; ANSI/AWWA Cl 10/A21.10-08 and NFPA 3"-12" UL Listed (EX21 11) Note: Cast with tested and traceable ASTM A536 Ductile Iron 2"- 24" rated @ 350 psi; 30"-48" &all fittings with flanged branches rated @ 250 psi Note: With use of special flange gasket 2"- 24" flanged fittings can be rated @ 350 psi For 350 psi flange joint applications, we recommend the use of annular ring type gasket or comparable. Fittings 2" - 12", *5°maximum deflection & 14" - 48", *3° maximum deflection Note: If pipe O.D. &fitting I.D. at nominal, achievable deflection is -50%of maximum Meets all requirements, UL Listed (MH16439) M 8 ANSI/AWWA C104/A21.4&AWWA C110/A21.10 - L ANSI/AWWA C104.A21.4-08, o Double cement lining available 0.1s ANSI/AWWA C116/A21.16-09 IIIN' IIfhi -- Note: Fittings are available to the IU � h S \\ \\ specification(s) required for your application(s) % � :�� \` \\�a\ Available - P ANSI/AWWAC111/A21.11-7 0.12 - AWWA C600-10 using pipe K2 J D C A N F K1 conforming to ANSI/AWWA C151/A21.51-02 or ANSI/AWWA C900-C905 Size A B C D F 0 X J K1 K2 L M N O P S 2 2.50 2.50 3.39 3.50 2.61 28"/4 4.75 6.25 6.25 .75 .62 1.12 .31 .63 .44 3 3.96 2.50 4.84 4.94 4.06 28° 3/4 6.19 7.69 7.69 .94 .62 1.37 .31 .63 .52 4 4.80 2.50 5.92 6.02 4.90 28° 7/e 7.50 9.12 9.12 1.00 .75 1.50 .31 .75 .65 6 6.90 2.50 8.02 8.12 7.00 28° 7/8 9.50 11.12 11.12 1.06 .88 1.63 .31 .75 .70 8 9.05 2.50 10.17 10.27 9.15 28° 7/8 11.75 13.37 13.37 1.12 1.00 1.75 .31 .75 .75 10 11.10 2.50 12.22 12.34 11.20 28° 7/8 14.00 15.69 15.62 1.19 1.00 1.75 .31 .75 .80 12 13.20 2.50 14.32 14.44 13.30 28° /8 16.25 17.94 17.88 1.25 1.00 1.75 .31 .75 .85 14 15.30 3.50 16.40 16.54 15.44 28° 7/8 18.75 20.31 20.25 1.31 1.25 2.00 .31 .75 .89 16 17.40 3.50 18.50 18.64 17.54 28° 7/8 21.00 22.56 22.50 1.38 1.31 2.06 .31 .75 .97 18 19.50 3.50 20.60 20.74 19.64 28° 7/e 23.25 24.83 24.75 1.44 1.38 2.13 .31 .75 1.05 20 21.60 3.50 22.70 22.84 21.74 28° 7/8 25.50 27.08 27.00 1.50 1.44 2.19 .31 .75 1.12 24 25.80 3.50 26.90 27.04 25.94 28° 7/e 30.00 31.58 31.50 1.62 1.56 2.31 .31 .75 1.22 30 32.00 4.00 33.29 33.46 32.17 20° 11/4 36.88 39.12 39.12 1.81 2.00 2.75 .38 1.00 1.50 36 38.30 4.00 39.59 39.76 38.47 20° 11/8 43.75 46.00 46.80 2.00 2.00 2.75 .38 1.00 1.80 42 44.50 4.00 45.79 45.96 44.67 20° 1% 50.62 53.12 53.12 2.00 2.00 2.75 .38 1.00 1.95 48 50.80 4.00 52.09 52.26 50.97 20° 13/8 57.50 60.00 60.00 2.00 2.00 2.75 .38 1.00 2.20 Tyler: 11910 CR 492 -Tyler,TX 75706-(800)527-8478 Anniston: 1501 W. 17th.St.-Anniston,AL 36201 -(800)226-7601 Corona: 1001 ElCamino Ave.-Corona,CA 92879-(866)527-8471 Portland:6204 N.Marine Dr. -Portland,OR 97203-(866)527-8471 www.tyleriin6on.eom tN '' In-Building Riser e-- C t __,___ �.�—.�-�.. ._ ,"Specification ., The In-Building Riser shall be composed I of a single extended 90 degree fitting of 1z fabricated 304 stainless steel tubing, maximum working pressure of 175 PSI. , =--Building perimeter wall The fitting shall have a grooved-end connection on the outlet(building)side and a CIPS coupler on the underground i !MR(inlet) side. `i ti Al1111111MIIMIM The fitting shall be similar in all respects to Building floor r the Ames Model"In-Building Riser"as '' II manufactured in the U.S.A by AMES Cil- ---Flow Company,Inc.,Woodland,Ca.,or 1.:::;,.!-. i approved equal. Operating Description ---- ixfiatiladisig Riser,"manufactured of eTkE;SOO stainless The In-Building riser is used to connect r, the main fire supply to the building overhead steel.Using Twenty First Century technology,AMES has fire system.The fitting passes under the succeed c it the nlanufacture of a durejlie and easy to foundation without joints and extends up through the foor.The unit has a CIPS(Cast iistcii underground transition d Ming, bring municipal ifv �. �P. r F viat,ey swolly int(2�a imili�in�.ha 'uil:di g riser is ifi..aii d Iron Pipe Size)coupler for easy connection v to the underground supply(AWWA C900 suited tsr °is'a rdvoiectfr..d ss €s. PVC)and an industry standard grooved-end connection (A\X/WA C6O6) on the building side for easy connection to the overhead fire sprinkler system.(Provided with. e ' x x t`� f 7 r .J installation tabs). '. '1 , y { li Features/Benefits .Cost Savings 'Minimal Site preparation or joint *Sizes:available in 4"through 10" restraint one-piece construction with various lengths to meet all local Q .Corrosion Resistant-stainless steel reduces time&labor:no missing requirements construction type 304SST parts,no leaks,easily identifiable e Designed to meet NFPA Ease of Installation-lightweight for approvals 24 Section 8-3.2 allows one person to position& UL/FM Approval handle the riser °AWWA C900 Inlet 'AWWA C606 Outlet t), ‘ F 1 c. , irl P.1 Of YipX# k l , ,IIA, €' 4-1`1,t 1. ' A A Division of Watts Industries,inc. H CONTROL _% FLUID SYSTEMS 530.666.2493 . 2485 Tanforan Avenue o P.O.Box 1387 o Woodland,CA 95776. FAX 530-666-3914 H I In-Building Riser II IDimensions End Connections I Size in. A B C Weight Bell End:Mates with Ductile Iron Pipe and in. ft. ft. lbs. AWWA C900 Pipe(PVC Pipe with Cast Iron I 4 41/2 OD 6 6 71 Pipe Equivalent OD's) 6 65/8 OD s 8 85/$8 OD 6 s 6 98 129 Size Mating Pipe OD I 10 103/4 OD 6 6 202 4" 4.80 Each diameter(A)of riser is available in the following P.6" 6.90 I vertical/outlet(B)and horizontal/inlet(C)leg dimensions. 8" 9.05 Call for weight. 10" 11.10 B 5 C _ I ft. ft. Utilizes Gasket conforming to UL 157 with 5 6 A "Lock in"gasket configuration I s 6 e Grooved End s s I I Grooved End 1 Meets AWWA C-606 dimensions for roll grooved pipe I I Ratings Meets AWWA C-900 pressure class 200, IDP 14 Pipe I LIPS Coupling Tie-Rod bracket..-_ I ! „, 4=11111111W Welds are 100%leak tested at the factory (11A1 •.. Size Design Proof Pressure(psi) 4” 875 I C I 6" 875 3" 700 I10" 700 I Ames In-Building Risers are precision comparison to traditional installation engineered and manufactured to provide methods and materials.Factory tested Standards I exceptional reliability.The Ames In-Building integrity ensures the highest quality Risers significantly reduce installation time installation. NFPA—Designed to allow the contractor I and labor costs associated with field assembly The use of stainless steel significantly increases to conform to NFPA 24 Section 8-3.2: the reliability and life of the Riser. Where a riser is close to building accordance with NFPA-24,the UL/FM I Approved Ames In-Building Riser replaces To learn more about the many foundations,underground fittings of numerous fittings,elbows,spools and reduces advantages Ames In-Building Risers offer, proper design and type shall be used I the possibility of leaks or failure in contact your local Ames Representative. to avoid pipe joints being located under the foundations. INFPA—24,7.1."1,8-3.4 IApproved IFittings FM class 1920 I AMEOS UL (HKOX) A Division of Watts industries,Inc. IFLUID CONTROL SYSTEMS 530-666-2493 • 1485 Tanforan Avenue • P.O.Box 1387 •Woodland,CA 95776• FAX 530.666-3914 If183-50 2/00 • cerro ..., COPPER TUBE FOR CONSTRUCTION APPLICATIONS 1 ,, � ` Cerro tube is the original copper tube for plumbing,air conditioning and FFa > i refrigeration applications in residential, commercial and institutional ° installations.We provide a complete range of sizes and types, engineered r ; } to exact specifications to meet the highest standards of performance. j� Zf : i ors , !i)t - Y.. -S �`, Copper Hard 10 ft.straight Green Domestic water ASTM B88 Water Tube, 20 ft.straight service and 4-,.,-,t,. TypeK distribution,fire ,'^ . (heavy wall) Soft 20 ft.straight protection,solar, '-'42.- V" 40 ft.coils fuel/fuel oil,HVAC, 60 ft.coils snow melting, 100 ft.coils compressed air, natural gas, Typical uses include: liquefied petroleum (LP)gas,vacuum •Type M - above ground residential and light commercial uses.(Sizes range from 3/8"-8" Copper Hard 10 ft.straight Blue Domestic water ASTM B88 diameter) Water Tube, 20 ft.straight service and Type L distribution,fire °Type L-residential and commercial uses. (medium wall) Soft 20 ft.straight protection,solar, (Sizes range from 1/4"-8"diameter) 30 ft.coils fuel/fuel oil,HVAC, 40 ft.coils snow melting, °Type K-underground residential,commercial 60 ft.coils compressed air, and industrial uses.(Sizes range from 100 ft.coils natural gas, 1/4"-8"diameter) liquefied petroleum •Type DWV-ASTM B306: used for drainage, (LP)gas,vacuum waste and vents Copper Hard 10 ft.straight Red General plumbing ASTM B88 Water Tube, 20 ft.straight and heating purposes; Type M drainage waste, (light wall) vent and other light pressure uses. Copper Hard 10 ft.straight Yellow Drainage waste, ASTM B306 Drainage 20 ft.straight vents,soil and other Tube, non-pressure Type DWV applications Copper UNS No.C12200 Types K,L,and M ASTM B88 Color marking is not applicable to tube furnished in annealed straight ,zA lengths or coils. rr M Flow Products,Inc. Corporate Headquarters PO Box 66800•St.Louis,MO 63166-6800 888-237-7611 !618-337-6000.1.618-337-6958 bpi. A member of The Marmon Group of companies www.cerroflow.com COPPER TUBE FOR REFRIGERATION APPLICATIONS Copper Soft 50 ft.coils Manufacture, ASTM B280 Refrigeration 100 ft.coils installation and Tube maintenance of fir i Win, refrigeration .. ;`r; �s .Y•S equipment Copper UNS No.C12200 1 ASTM B280 Refrigeration service tubing-a seamless copper tube produced to a standard 3r, J 1 range of sizes and to special internal cleanliness and dehydration requirements, _ -.. ` normally furnished in soft temper coils and with ends capped or sealed. It is a preferred material for use with most refrigerants. COPPER TUBE FOR MEDICAL GAS APPLICATIONS Copper Tube Hard 20 ft.straight Green Medical gas, ASTM B819 OXYMED Blue compressed medical air, vacuum fir= a e 2 Medical Gas K OXY MED ASTM B819 uw This tube is specially cleaned and capped.Special care and handling is given to this product to prevent contamination of the system. Our Type K and L(cleaned and capped)is also specially cleaned for use in med- Note: Plumbing and mechanical codes govern what types of ical gas systems and meets the same allowable residue limit of 0.0035 g/sq.ft.of products may be used for applications.Local codes interior tube surface area.All of our Type K(cleaned and capped)tubing is fitted should always be consulted for minimum requirements. with plastic caps after cleaning to maintain the clean interior surface. Our alloy C12200 seamless copper tubing is manufactured in the USA and is produced in compliance with the applicable Gas Tube chemical and mechanical properties of ASTM standards. For over 30 years,gas companies in the U.S.A.and Europe have used copper for fuel gas piping. For TIr.,c¢taning and p icitag infor f.aiios1, Some advantages of using copper in fuel gas piping include: o<>a re,R.rw.c;rratiow.co:r1 •Flexibility or can to i .. 80e-27,7-.15-,1 or 613-337-60:0. •Ease of bending •Compact sizing f M •Ease of joining � TM •Resistance to corrosion Flow Products,Inc. Corporate Headquarters PO Box 66800•St.Louis,MO 63166-6800 888-237-7611 618-337-6000•f.618-337-6958 ...... .Amemlxr of The Marmon Group ofmmpamm www.cerroflow.com 7}a,S 7: *14 .1.'-,--=-7M;."-;_'•'t :N `.4.sr ' .;i s r t-�' � _. W i. e:_: c"" 4-* - � a�..� (FIRE� a t r:4Ik�"��4�`C .-�`'t+' *�'_- '"�'� � �r "x' r ..-.'�. s .r. RDKE DEP�TI IN T � I R TYPE . 8°05 6425 SER ,tom x a� .,=av, � "� � A Zkx.ra?.°� mod self4.;` . a� F y"A ,, `. .x ,_ a %1 a'r1 '- , "q,t i :''''A,'::.;A=4 e"t ' rn Ti" . m a'L'•.` ;,,,--11,3,,,..: ... ... ,' _ . � , . SINGLE T 4 �Sdcg Q LETS i° "--°1 An exposed auxiliary inlet connection with 500 G.P.M. inlet capacity to supplement fire protection water supply. Exposed c design provides an economical method of satisfying Fire Dept. ti =`1' =m l inlet requirements. I 1114, • • _t STANDARD EQUIPMENT: Cast brass two-way inlet body only with single swing clapper and pin lug swivel back or angle —� B-- Figure No. 6405 outlet connection as selected by figure number. 6405 Back Outlet SPECIFY THREAD. f BRANDING: "Auto Spkr." FINISH: Cast Brass *U/L LISTED A OPTIONAL FINISHES: PB- Polished Brass v '# RC- Rough Chrome Plated PC Polished Chrome Plated ` E I \. Outlet Dimensions AMY zs. *�"' Model Style A B C 6405 Back 51/4 8 5/64 6 1/2 6407 Angie 6 5/16 7 11/16 4 3/4 Figure No. 6407 6407 Angle Outlet DOUBLE CLAPPER =VIA INLETS - An exposed auxiliary inlet connection with 500 G.P.M. Inlet rF ,I . capacity to supplement fire protection water supply. Exposed A �* .{ t . ;I design provides an economical method of satisfying Fire ` % Department Inlet requirements. e • STANDARD EQUIPMENT: Cast brass two-way inlet body only s • I with double drop clappers and pin lug swivels; back or angle g I Figure No. 6410-6415 outlet connection as selected by figure number. Branding 6410 Back Outlet as selected. SPECIFY THREAD AND BRANDING. BRANDING:"Standpipe", "Auto Spkr." t 6 E — ( ; FINISH: Cast Brass 4 �'a s ) OPTIONAL FINISHES: If , ' PB- Polished Brass -, /" RC-Rough Chrome Plated 1 • • PC- Polished Chrome Plated 1 c . Figure No.6420-6425 6420 Angle Outlet *U/L LISTED NY BSA-MEA APPROVED Outlet Style Dimensions Back Angle Size A B C D E *6410 4 X 2 1/2 X 2 1/2 9 5/8 12 1/4 6420 4 X 2 1/2 X 2 1/2 11 3/4 9 5/8 7 1/4 6412 6 X 21/2X21/2 10 1/4 1 1 3/4 6422 6 X 2 1/2 X 2 1/2 12 1/2 10 1/8 7 1/2 6413 4 X 3 X3 10 121/2 6423 4 X 3 X 3 12 1/2 10 1/8 7 1/2 6414 5 X 3 X 3 101/8 121/2 6424 5 X 3 X 3 12 1/4 10 1/2 7 1/2 6415 6 X 3 X 3 10 3/8 12 1/2 6425 6 X 3 X 3 12 1/4 10 7/8 7 1/4 Page 6-15 . > :., £'ti L, " ': fir ` F a + . ^'- a '''';'''..:1'',":'----3:1. p , a 7 v * d a'H E , , z y t` ' `L ,s ki. 3 . s j f #s• `,- ` . r a t, L �¢ -,, ', x , • -1,f.` { ; 'i - x i a " r - ./ z , , ,„ �` � s ,.i 1 f h a , t'1,1'..-;' ,� & #F t �y "�;''''''';'-'5'1 a a t �+ 'r - A .rr : vr' }a u -4„,,,,,,,� x --'—_ r { g 1 1 ,a - i .TM Sant-21 0 PVC Sever Pipe SPECIFICATION DATA 3y E e t $' r' h 1 1 Fite r i '' +�`°yly �. 't"` ` 7 .f= 'r1 ,{, ?•,�.� ,, kY :�=# y Fj / ,, . • "tax' . r a 5 Alfi" rr 1 ' Diamond gravity sewer pipe 4 inches r ,r:s,. eft•, }, through 48 inches shall be made of l 4`'� {�, ` ;t ; ', ` f . _ u compounds conforming to material 1 %%,r- ••.�.1' - -r ��1 E '� 1 requirements of ASTM D3034 and ' `' '` ° ' e ) "�• ASTM F679 in accordance with `ik_r,£ 5 ,t f ! j ,,�+ ASTM D1784.Diamond PVC Sewer `°#?, 4 # w f" Pipe meets all the dimensional, r"` *'. •j � . 4 s chemical,and physical requirements as " '� .., ¢ - T4't�. , ' . ti , . outlined in ASTM D3034 and ASTM F679. �'' � � '� t The i e sizes 4 inches throu h 48 inches V" ' r ;'S i`� : ,'b ,' q�', pp g ,+ { are made with an integral bell S r "orY�° ;�r t °� ► ` ' "water-tight"joint that meets the `. {'04 ` it r ` ^ _ ti �� `*"• requirements of ASTM D3212 and that ' ��t ;�lJ. _ , utilizes a Rieber asket s stem for k ` 9 Y ,fit." '. t , ` , - T sealing that meets the requirements .- �-'cites �,..`, ' •.':° "' -*ter, . , 4, . of ASTM F477. Each male end shall be beveled to facilitate joining and referencing marked for proper insertion depth.Diamond furnished lubricant is to be used in the joining process. + f ' 0. i t � s J >. s F # u _ #�z6 s i • f q k � ,2}' , (° °.l d ? 9 £ ` dg 3x x $ ,x r � 'x s q y; °e a Q �2 t ,` rt Pipe Materials: Pipe Modulus , Pipe shall be made of PVC plastic having a minimum cell classification of 12454 or 12364 as defined in Specification SDR E= 400,000 E=500,000 D1784. 41 28 35 Property ASTM Minimum 35 46 57 ' Test 26 115 144 Specific Gravity D792 1.40 Standard laying lengths are 14 and 22 feet j Tensile Strength,psi D638 7,000 Tensile Modulus,psi D638 400,000 IZOD Impact Strength, D256 .65ft.,Ib./in. SHORT FORM Specification for Diamond PVC Solid-Wall Sewer Pipe SDR 26 or SDR 35 or PS 46 or PS 115 Diamond PVC Solid-Wall Sewer Pipe shall be made of compounds conforming to ASTM D1784 manufactured in accordance with the material requirements of ASTM D3034 or ASTM F679.Diamond PVC Sewer Pipe must meet all dimensional,chemical,and physical requirements as outlined in ASTM D3034 orASTM F679.Diamond PVC Sewer Pipe shall be installed according to the requirements of ASTM D2321.Joints shall meet the requirements of ASTM D3212 and shall be formed using Rieber Technology.Uni-Bell UNI-PUB 6,"and the manufacturer's requirements." IAMOND PLASTICS° ��0 : Corporate Headquarters• 1212JohnstownRoad•P.O.Box1608•Grandlsland,NE68802-1608 page ,thirteen 'Si TM.Sani-e. 1 . PVC Sewer Pipe .... ..., ___..,... / . ...., N (. SPECIFICATION DATA St:1'j i 17.4. / TM \ Reiber Joint Illustration . ' 1 . :,-:-Iii-43 14 II. milioNwriiik„Adt 131 l''' ',..•.: ' ,111 LIH, . A I/a,,:'''. '"r'* ■'. I ,I.igilli4.1101--...' . • . . •,f/Pr ' se : "' ,,. ... li- q 1:',Iying IcnIgillS„ , . , yei::.-v7:it,,t..,f1:;/;irl",... ,,, D3034&F679 SEWER SPECIFICATION DATA Strength . . . . . . . , ,...,,gss. ..<> --,,,v„,,,,*.", if -,.., ''. ,,,,..--9,....d :.:,.: -.-:z...14 --i- 4 '*.n.;:4;-:....,t:::- ,f,,5, :':i:Iv''', **41.,,ff.!4° ,':.".:1*,-,'''.'.ii1:4471.4"': ,f... A'4•17Ft..C-'el': '' 1-5/PAS41,4' ' I ' '711tW'::'1-41trk :• Pe 41:4),I...154It4I2t- I „,,,,s,1' 4.'..IIPI-E:42 . ' ,7,-41'f;.:Zel, .,,It,-, t.... ., .,, 1/4,4 ri.,,,.. _oli;-vain#:-4v:1,-„,,,I,,-1 yif.),..=.;a:=o4A,Z.,4 wi,Jit ....f4S-- e,,.. 44,-...; ,-..y...;,: -,,,.,.,,N.,.P7,,,:,,,-.1, .: .- t;.1 Y2i=iti5t,ri.4;4.f,..s..4"::.,&f4,,,,,.......-1,.......,Aik e2.L'.1...,.._'-:.'„:.....-..:::::,:,:"1.2 a...4.ZA1,.:.1E-44W....-.tISI: 2:-..-,....±....,..I.A.s. .I... ,4'. ‘A.r...11..,.,.. ,"..- '14........L..-Li,. ... . • '1411g1114C14AV614.6*7 7 7:.i:) '4", . , '...1,.... ......"-- . , ,,,,,....2.a=li.-,,,,,,",=7.,,K,,,,J7,0 4 4.215 5-1/4 4-5/8" 4" 0.162 0.120 6 6.275 7-1/2 4-3/4" 4" 0.241 0.180 8 8.400 9-7/8 6-1/8" 5" 0.323 0.240 10 10.500 12-3/8 6-3/4" 6" 0.404 0.300 12 12.500 14-5/8 7-1/4" 6" 0.481 0.360 15 15.300 18 6-3/4" 6" 0.588 0.437 - '-' ''' .'' '''' '•''-' ' ''' ",- --- - - --------,,,,,,,,,,,,. -.3 , --,.,..'.-.',.,...-7,,,,,,..,,,,,'.,:,-:_--7.,7'.,4 -:-.,-.,...,7.-7.-_,,--.....7.=. III'.4-IV;-'1‘4.kitt -Ill'4,*"7310-f.± -1. .,".• , , 18 18.701 21-3/4" 7-3/4" 7" 0.671 0.499 21 22.047 25-1/2" 7-3/4" 7" 0.791 0.588 24 24.803 28-3/4" 8-1/2" 7-1/4" 0.889 0.661 27 27.953 32-1/2" 8-1/2" 7-1/4" 1.002 0.745 30 ciod 32.000 37-1/4" 12" 10" 1.148 0.853 36 ciod 38.300 43-1/4" 12" 10" 1.373 1.021 42 ciod 44.500 53" 16" 13" 1.187 48 ciod 50.800 60" 16" 13" 1.355 "Possession of this page does not constitute an offer of sale" Prices are subject to a firm policy of"Price in effect at time of shipment on regular purchases" DIAMOND :',,,1!..) PLASTICS® Corporate Headquarters• 1212 Johnstown Road• P.O.Box 1608•Grand Island,NE 68802-1608 -----w-47,74;;,--Tr4i, ' ,... ,;',. 4VAY-0,714 ,';',N,1,,,Agli*,. '1".: 114.7."... ....f:14..0,p'4,0,:,/,„‘": "',..4,A;'1,','''.''•' -..'.11",'-' '' '' ....,,,,,- 1Unr.,,,';',',.,' ,,,,i''''' '..:;;,::',,,"::k''';'7,7;;".).::?:','''''-';.f...g,:'.S.','4*;'';''''''*'4':t.'Vlif II' .-""'4. ":-7.4. ,...'.! ''' '''''1,,,,,,, ,..;41:01..'"IP';\' .. ,-.. ',;..... :... . ' ' • V2_.;ie,441k1FA.17.4115,4t;;.A44,,,14€.: 74"!.aiiAgt4t404i4-::;:'!:4: 14F24Ot . ,..''Pi4'1F!-J:!...4-4tarlit:lr4 -:1..!PVI::' .',„4'.4' --- Nsrlivt.' 7,i" .4-.,14,1st '- .:-..,..',."1-i... ,-,,,,,,,n-,-. 7,- --; 7 •-:.- - "A”:0''. • AI"' N..,--..*'''',f.'4',4"7*:',?..W.,-T-",."-..4423-7'0"...,4,P,:`- ' - :'• '. '' -- :4,-, •:,-.0u: 0 j:;:n,..p..14,,,,s*tktkAe,r.v.41144-ept,,,,,*z,.&..e ,7 .;k4.,,,A4.. ..," %.".,.: f...4," ...4. ',1r,. ,:,"'4,"., ,,ii.'"1,..40.:' ''4.'":"IT.'-.. .,,,k..F .:',.,,-.1,-. -"Piri4,:•4",-."-";...;';',.. .Or"--,-.",.'"Iit.",r .4.-"; 117,,, ,`,.' '0",,q,,-,,e, 4"''',.-4.-iit... ,, ,-A,',It.'J,,,,:t.:„."'ILL.,.-i,".•s.,:t..",,..-,.4.-..":i,- z., -.,' Series 671 PLASTIC TRENDS Quality Fittings By Design cpnologY.� 1 4,. U L fi v N 'rriNo Plastic Trends SDR 35 supplies the PVC STIT"' Gasketed Sewer Fittings only fittings with Injection Molded in Sizes 4" - 12" Triple Certification (Fabricated sizes 15"-36"are available) listing Features • 4" -6" reducing branches on 8", 10" and 12" fittings have a minimum wall thickness of SDR 18. • Extended Pre-Alignment Entrance. • PVC One-Piece Injection Molded. • High Performance Gasket. • Generously Blended Branch Intersections. • Square Pipe Stop. • Specially Formed Raceway. • Heavy Duty Support at Branch Intersections. • Rounded Edges to Minimize Stress Points. Applications STITM Gasketed Sewer fittings are intended for non-pressure drainage of sewage and surface water. The Next Generation STITM fittings are the next generation of strength and quality in gasketed sewer fittings. They combine the latest in research and development,optimizing the best of today's Science,Technology and Innovation. Triple Certification Listing STITM fittings are the only fittings in the industry with triple certification listing. They are third party tested and listed by NSF,UPC and CSA to meet specifications defined in ASTM D 3034,ASTM F 1336 and CSA B182.2,where applicable. New Features A one-piece integral bell and an extended pre-alignment entrance aids in proper alignment of pipe and fittings. In addition to scientifically formulated resins,square pipe stops resist pipe push-through while extra heavy support is provided under the Our branch intersections are reinforced against pipe stop at branch intersections for added strength. stress and breakage to a degree never before available in a PVC sewer fitting. This means Setting The Standard the weakest point of competitors'fittings is just As the only manufacturer to offer a complete new line of innovative gasketed tooling, another strong point in Plastic Trends'fittings. Plastic Trends sets the standard for PVC fittings produced in the industry. STITm gasketed sewer fittings represent the latest evolution in PTI's continuous effort to offer the most technologically advanced fittings available. If you specify,distribute or install gasketed sewer fittings,demand the most advanced fittings available,STITM. See available configurations on the opposite side of this sheet. Form#0280 Rev.2/06 Series rZi ,_:k___iy r Configurations Available Fr 4i Nilimir PVC Slim, Cask ted r Tiii' Sewer Fittings i (1 • ,, , /•,' )4, i , \ Injection Molded in Sizes 4"- 12" "i 4 ir ' `--,4' Fabricated in Sizes 15"-36" T TEE TEEW/DWV BRANCH SANITARY TEE xGxG GxSxG GxGxDWVH GxGxG III. 1 I g. 7- I ,_ Short Form Specifications I , t f 1 4"through 12" injection molded SANITARY TEE WYE WYE WYE W/DWV BRANCH gasketed SDR 35 sewer fittings shall GxSxG GxGxG GxSxG GxGxDWVH I be manufactured in accordance with ,� ASTM D 3034,ASTM F1336,and CSA �I B182.2.They shall be injection molded v„ from virgin PVC compound having a \, cell classification of 12454 or 13343 in �q i i ,� accordance with,and certified by the COMBO WYE&1/8 BEND DOUBLE WYE DOUBLE WYE 2-WAY CLEANOUT National Sanitation Foundation (NSF), GxGxG GxGxGxG GxSxGxG GxGxG to meet ASTM D 1784.Gaskets shall be manufactured in accordance with R-- ,__ ASTM F 477 or ASTM F 913.Gaskets 1 . shall be firmly seated in fitting in order `�' � elks, L r,,. to ensure proper installation and to 4__ prevent dislocation or misalignment 2-WAY CLEANOUT(DWV) CAP SPIGOT PLUG TEMPORARY PLUG during system assembly.Gasket joints GxGxDWVG G S S must comply with ASTM D 3212 Internal Pressure Test(exfiltration)and Vacuum Test(infiltration)at 5 degrees of gasket joint deflection. 't, `L i" Where available, reducing branches on REPAIR COUPLING STOP COUPLING CONCENTRIC INC.COUPLING ECCENTRIC INC.COUPLING injection molded 8", 10",and 12"tees, GxG GxG GxG GxG wyes,and tee-wyes shall be minimum DR18 wall thickness in the reducing r ", branch body and reducing branch hub I ' below the gasket race. 1- d,,, r' Vatii;j Gasketed SDR 35 sewer fittings shall CONCENTRIC INC.BUSHING ECCENTRIC INC.BUSHING ADAPTER DW ADAPTER SLEEVE be certified by the National Sanitation SxG SxG SWRSxDWVG DWVSxSWRG Foundation(NSF)and,in applicable configurations,by the International Association Of Plumbing And Municipal "'v f~ '�" r Officials(IAPMO)to meet ASTM D 3034, and by the Canadian Standards - ' ' Association(CSA)to meet CSA B182.2. RISER ADAPTER DWVADAPTER ADAPTER ADAPTER SxS SWRGxDWVG SWRSxSWRG SWRHxSWRG r Triple Certified Listing � 4' as -,_. - $ 1/4 BEND SW ADAPTER DWVADAPTER DWV ADAPTER :4-:' ,-R GxG SWRSxDWVG SWRSxDWVH SWRHxDWVG SWRSxDWRH i PLASTIC TRENDS r )�, \\ L___",-N.,/Plastic Trends,Inc. ' 56400 Mound Road !. --- - Shelby Twp.,MI 48316 1/4 BEND 1/4 BEND LONG 1/4 BEND LONG 1/8 BEND 1/8 BEND 586.781.2700•800.232.5690 GxS GKG GxS GxG GxS Fax;586.781.0888 wvnv.pIastictr ends.ccm ,' { -.. i. . gam 16 BEND 1/16 BEND N-LINE BACKWATER VALVE TERM NAL BACKWATER VALVE 3 GxG GxS GxG GxG Royal Group Technologies For additional configurations,list prices and dimensional drawings visit wvrw.plastictrends.com ''',C,, ,�` x . ,,� ,,� ,may � ''...40‘-‘. • 'F ,�« r qtr : I �' �} t ,. - -'5:., :._ 'E' ,°�`'1 i``�gew�" - #:- , _T��._i y�'�` ` k ' 'w t'':,::',1` i`` t o t 1" ,,,,r5.„1, �,'2s_'"P< . '.1. r.P-::;;; `- - r..,€x'� ':�..� 9A T yy ,� _.-1' �• �{ F• kA VVess 0 . - I' r i 1--„, _, 2 ,, ,' p,i,' . ,''' -Y., '''' C ',>-'2 1, ::16: ".. ' - s ' - .. ' '. 1, s,,, . .1 a.J-- P.: : a �z :, - -,9 i- iit, tt _ _isr,. .60.- ... 1,0 i •.. _ .,i� a -� § :z, iii: .ter 1, :14 3�'• 7 1 ! �t1t . sr;�- _ ti._.- � rr a� 'ii..`. ..'Y. of}I�• ���. lig i st . .. _ .. .. . _ ':- ;1 rfr,,. 10, ,may I� �` 1,.,,k, ��'--mir ,7m.-...i7,11.-- - - am, I K .. $ :"- f• } ' _ u kritpF 4froit :• 1 . ,_. ..-,,,. : . ...,.,,.._,:. . , - .t.,::.,., .. .J '; . ,...,nati...,---, k , - 44;,.iy 14 .' -, „.. : . „....t • .,.. ,:,,, _=_-,__.:. -_-. . --, : ,,.... i , i __ —ply .i. igti ,..„,,„. .,;:t _ .40 ,.,_,, litio, + ..S vL �yS �- YtY Y JII A / _�,\•:^ .,.,_. '•Y• h:'vim? •d..,: . - l'='�'N „+'' w,I � �s - y,. - n...,': .<. 1, 3ar Lak. .. ,fir: • ,It. v .. .<r , -,',. .....,..v.;:.., ... :.:K v.� _ .:.,ai x y. .. .. . -.<...,.. ...... . . ... a 1 ,n, � 'r f� t ;= :µs ' -4,,r;oJ PrhouctS � �, rr 1 'Y-.v, tit• A • I,V +':t e�kUtiLlties�: - .,, - :"ice - ,; { -',' _'Indust 1 r'_ �:..�. � R':ems , ' '. S!C.``•- -,- Y'. • :' � .. '1,•- ,w- 44:"tr4• vI4' y •4 V te 7' y T 1 ^ - TS ? _ .Y r kWS � .L i+'! t .� y w; ;b •,,....,!-."..:`,1,M- {, YY .'t t R h; - . ....',h I } 7k C r ... _ ( q f fi J ,-?, ,; r 4), t�-. 6 1;i19,f'°i x ii ii, 1 ,f-,_k `'.k r 4:3 '� l.),, '� re LT i.f �,,,, rrt, (, -$.. tf4 ..3 l ..tee{ The Wastewater Access Chamber The basic concept of a manhole has remained unchanged for more (WAC)and the Cleanout/Sampling than 150 years.The original function was to provide an access point Chamber(CSC)are rotational-molded polyethylene chambers designed to into the sanitary sewer system large enough to allow two men to provide access into various locations enter and perform inspection and cleaning procedures manually. in sanitary or storm drain systems for Over time, due to technology advances,the need for human entry inspection,sampling and cleaning. into a manhole to perform routine maintenance operations has The differentiation in the products almost disappeared. are the physical size,the pipe sizes they connect to and the conditions in which they will be installed. The latest developments follow the technological advances in both function and materials.PW Eagle has provided products Ls k Genez-a eat-wakes consistent with the materials used in most sanitary sewer systems -plastics.For many years,Europeans have been developing and Heavy Wall Polyethylene utilizing polymer technology to manufacture chambers to replace Construction conventional manholes.In 1990,the introduction of the Wastewater • Lightweight for easy handling at job Access Chamber(WAC)in Dallas,Texas,began the transition of site the U.S.market away from conventional pre-cast or poured-in-place • Light color, better visibility on interior concrete manholes.Since the long-term performance of concrete, • Lower installation costs particularly in corrosive environments,has not met expectations, •Water tight the time is right!PVC sewer pipe •Corrosion resistant L - w 7 "" .v ` has gained the major portion of the ° Flexibility under earth load --,� - new and rehabilitation collection ° Excellent flow characteristics(n=.009) system market,so it's only natural ° Economical compared to conventional manholes to make the change to plastic •Adaptable to all pipe materials access chambers.They not only °Smooth interior reduces > ,„a provide a long lasting,cost effective cleaning frequency alternative to concrete,but they •One-piece, molded construction-) . 4 are also effective in minimizing • Eliminates man entry for k� 'y maintenance purposes � � - �`,� the • dangers involved inhuman entry into confined spaces.What a • Reusable in other locations fi r," winning combination! • Resistant to shipping damage •Resistant damage from mechanical cleaning equipment P - -+ v • Proven material history 7 t , :. .' . � � 6 h�s x f ° Excellent Environmental l Stress , { � � � Crack Resistance(ESCR) x eft ,i4 1j - 7' 4.,i14 t".d Y"�" a ° ,; P y� , ,` � � Inlets/Outlets Designed 4 x�.� , ' ". „ v � : s / T� TO Accommodate Standard , '., `02 s g �� ;A '4 Pipe Connections With ;r " * i ,: :: 7f 5 " n O 5 Flexible Connectors : � r � �:% � ki;'.4* 1 a ' , s � ®Conventional installation procedures s : ,% t. •Watertight joints . © Nospecial components required '. ` '� - ';;,4:: ',":1,,,.,,,i4� 6 ,4,4'., • No special tools required `.F, 'r a' s€ - , w , ., r.',,,, l ^4' " ' ".r '.y Wi s4. p ewer s ,, m- ,07 " if % OP V A L Viltalt Q tt0 C ! nnC� rle Q Wastewater Access Chamber Features Chamber Body 15" Riser Pipe OnWAC Surface Treatment • Sturdy, 3/8"thick, one-piece • Large enough to allow equipment • Standard ring and cover installed on construction- no welds! entry,too small for human entry concrete base remains independent • Smooth interior improves the flow •Water tight lid with gasket installs in of riser pipe-no traffic loading (n=.009)through molded inverts top of riser transferred to riser or chamber • Large enough for easy insertion of • Extends or shortens easily • Polyethylene lid with gasket installed CCTV equipment and high pressure • Eliminates need for confined space in riser, under ring and cover to cleaning equipment entry procedures and equipment eliminate inflow into the system-no • Design resists floating in high • Due to 15"size, riser remains "dish"or casting to chimney sealing ground water conditions independent of standard ring and devices required! • Light color allows for excellent cover • Freeze/Thaw cycle effect minimized internal visibility •Street paving adjustments made independently of chamber WAC Installation ,--Cut as Required for 15'P.V.C. 6,B,10,12 inch Pipe SDR 35 ■ Along Coding G Water ii hl Ada for 'i t to PVC p 1 Palyethelene Dimensions Of Body X 1 1': Access Fitting Water Tight Adopter Riser 1 PVC to PVC for PVC Pipe - DETAIL A Pipe Gasket Cloy to INC for Cloy Pipe WAIL A" • Length 43.75" +/-0.50" \ Plug i • Height 37.75" +/-0.50" DETAL ' Pipe Embedment Sp ,f d on Plans ."S -mow---..• .� ��-� -•- - •Width 18" +/-0.50" Standard Cast Iron M.H. Frame&Cover per Clear nae •Thickness 0.375" average a .,i j-, Undisturbed Soil Ti 6p f t n DETAIL B 4 Min E.I II 6'Max. Pavement� Ex.Ground WAC LID ,, ... >. :4 „� 7�• '• __.. ,� - +.,mow-� ..,....---Lt N:+.E1 viii ti?/u, Woler Tight Plug ' Two Concrete Grade Rings '"sAps' N A (Minimum)and Non-Shrink i'.a. `r !E•G� X:FE Grout 15'P.V.C.PIPE I�:.: ".i. ♦ ALTM D 3034 r`.i I...'.'..'.'.;.I (50835) Undisturbed --STAINLESS STEEL COUPLING CLAMP .. Sol -..;..1� S 1 sane or slab'I zed sal P tl iek r t !F E�s+ • Compacted la 959.Sld GAS Kr tai R'.J,i i? 4)1 '�=___ t V 'tC i F;ql NOTE: {51.1 1.011:.!i+it'F �. —J ...,I Proctor Dens ty and Placed in roof 'a 14f sr 4 S itILIta!Mil t'ao*LING CLAMP 6-inch Lft s^ ' .t Beginning at the Wastewater , Access Chamber Working Outward 4 ♦ to the Excavation Walls "' ,=--Ti&FEiirti4 Ka(}S�lAMSER A. - STCO" t FIT. •• 6 m.'-; -:6''O,",. • COU i tar,tiije \ 11111111111100 ♦ Access Fine FLEXIBii P tr,--\ , Ac ss Fitt ng I• l', a� Compacted Crushed STAINLiq tlL[. y ti�� N ♦ Stone,Fine Gradation COUPL k.4.as►LE ++,, 1 ♦♦ ) Ef.,FiiG PIPE 12 _I EX ISiINs TciL— r '* - 4�'^ 6 ¢Iltlar STEEL , .. I ,« < �. j S4 EillwiSi'ttici ''', ,tM.Ii.4 BAND • t -, - COUPLING CLAMP —FLEXIBLE COUPL IIIG i Undisturbed •O•yv4-r•S*�y�rr•, Embeldmenfpe ':I Soil i..__.._..... .\ i MOLDED ACCESS PRODUCTS WASTEWATER ACCESS CHAMBER Exploded View of WAC 15 PW EAGLE J 15" WAC Product Specifications General and inspection equipment,without clay, cast iron, ductile iron, PVC or The Wastewater Access Chamber man entry.The chamber body shall concrete pipe through use of flexible (WAC)may be used in place of be a one-piece, rotational molded couplings. standard concrete manholes, polyethylene unit that is corrosion Physical Dimensions cleanouts, dead-end manholes, resistant, lightweight and designed for use in both traffic and non-traffic • Length of body shall be 43.75"+/-0.50" or sampling ports, or used in any • Height shall be 37.75" +/-0.50" location in a sewage or storm locations where the sewer pipe is • shall be 18.75" +/ 0.50" drainage collection system that 6-, 8-, 10-or 12 inches in diameter. • requires access for maintenance The chamber shall be adaptable to •Thickness shall be an average of 0.375" L te > L� k A 2.1 ` A 3 e ,' Cq f ; .9 � F � � 12" Riser Pipe On CSC " ' '' ' ''''44,..-.3, 77,4.:,,,.i.1 Chamber BodyI , •Sturdy 1/4" thick, one-piece • Sized to keep opening large enough rs construction - no welds! to accept standard pressure `it •Smooth interior improves the flow cleaning equipment and push-rod (n=.009)through molded inverts CCTV equipment e Sized to allow access by pressure • Small enough to be installed in cleaning equipment and push-rod sidewalk,yard or easement relatively , CCN equipment inconspicuously iii, i • Riser spigot designed to utilize 12" e Polyethylene lid with gasket installs 040 SDR 35 as well as 12" Ultra-Rib in top of riser to provide water tight s:µ pipe seal • 4" and 6" inlets and outlets • SDR 35 or Ultra-Rib may be used Cut-Away CSC connected to SDR 35 with flexible as a riser A , -,",, - ' . i -' couplings •Surface opening may be reduced w. . • Designed as a"Crow's Foot"to through use of reducing couplings � `ar allow two services to be connected (rigid or flexible) through one chamber, cutting main • Riser is cut to proper length at job , n` connections in half! site by installer Dimensions of Chamber Surface Treatment x • Length -26.425" +/-0.50" •Standard ring and cover set on a , ., ' , 4°` poured concrete pad may be used g� °,0,i_ '°"` • Height- 14.50' +/-0.50" p =- t0 gain access xx 'z, - '-= �e l 44.•Width- 21.00" +/-0.50" 9 •Thickness-0.250" average •Smaller rings and covers are '�' < . '; available for sidewalk,yard or _ / easement applications •Sealed polyethylene lid may be AST LID buried without ring and cover where ASi RING complete concealment is desired - , . coN nglalto,b,d ° S on •� QonsiPuel - 'a �' dAer,re Common Uses 12' SDR 35 PIPE 111 • Property line house cleanout(1 2 EANOUT houses) CSC Installation U I CAAMLERG • Commercial grease trap sampling ,� ,. �� CHAkBER 6„ • , , iAsi' ��--� SDR 15 PIPE port IMNIIS 1111Balt 11111 >1> _ I4 prY k +" �1 6' FLEXIBLE ' I d' FLEXIBLE COUPLING ' i j % COUPLING , #y r14 {! �, 4' 50035 PIPE $+s ' '�, }y 4 CSC Assembled Configuration .� V CSC Installation PWEagle manufactures PVC pipe for a variety of applications servicing the potable water, well casing, sewer, agriculture, turf, plumbing, communications and electrical markets. PWEagle products are available from distributors throughout the United States and parts of Western Canada. Our eleven facilities in Washington, Oregon, California, Utah, Nebraska, Texas, Missouri and West Virginia assure on-time delivery. =-, .:.'r P.O.Box 10049,Eugene,OR 97440 ^ (800)347-0200 e(541)343-0200 a FAX(541)686-9257^www.pweagleino.com f rye �`.1 '> 1 (:�0 1 "L _'rC21 Utho In USA on Recycled paper.Reorder No.MKT-W-756—December 2006 1.` J JOHNSON COUNTY PIPE, INC. An American Owned Company September 29, 2011 CERTIFICATE OF CONFORMANCE MSC Waterworks 11200 Seagoville Road Balch Springs, TX 75180 Re: 12" thru 60" Class 3 Reinforced Concrete Tongue & Groove Pipe This is to certify that the reinforced concrete pipe meets or exceeds the requirements of ASTM specifications C76, C506, C507, C655 and precast concrete box culvert meets or exceeds the ASTM specifications for C1433-03 (and/or C789-98 or C850-98) for the class or D-load of the pipe manufactured by Johnson County Pipe, Inc. for the above referenced job. Bruce J4tnson Project Coordinator 800 CR 209,P 0 Box 1588 Alvarado,TX 76009 (817)783-3444 fax(817)783-6002 h d Go-. r. I Wall WT Length * JT O.D. Wt. (Ibslff.) 12" B 2., 4'-0° 6'--0",8'-0" 2" 16" 96 Y. 15" B 21 1/4" 4'-0" 6'-0" /8' 2114" 191/2" 128 1 � 0 ie 18" B 2 1/2" 4' 0'/6' 0, /8' 0" 21/2" 23" 168 21" B 2 3/4" 4'-01/6'-0" /8'-0" 2 3/4" 26 1/2" 214 24„ B 3" 4' 0'/6.0 /8,-0" 3.. 30" 265 )_ 27" B 3 1/4" 4140176'-0° /8'-0" 3 1/4" 33 1/2" 322 t: 30" B 3 1/2" 4:-V61-0" /8'-0" 3 1/2" 37" 384 t # PIPE LENGTHS ARE ONLY AVAILABLE AS SHOWN. JT y ,• LENGTH A t 1. f is i. t 0 0 ,, o — • i F g t k G 2112"9J LIFT HOLE --� �- JT !' ON 27"AND t, i. LARGER PIPE ONLY r, I. G ■ Note: ft © All Pipe conforms to current ASTM C-76 Specifications for reinforced concrete pipe. Standard RCP Joint 4 12" to 30" Diameter i (sp SHEET NUMBER CEH BY: JOHNSON COUNTYPIPE,INC. SCALE: NTS DR. JCP OOOX h An 209- VAA O,"r v f. :8CR2893444-FtA�gTX7836 DATE: 06/26/09 CK BY JDH i PH:(817)783-3444 FAX.(817)783 6882 It f I ' t I I .y� i. i F Q i < 4 f / \ k JOINT / \ `, COLLAR / / / A' . / / , I I / A _ _ , Ci r:::i Id Ci — 1 P f f 2 112"0 LIFT HOLE I ON BOTH SIDES OF 27"AND LARGER RCP ti I Plan view r s f f `1 NOTE: 1. STANDARD WYE ANGLES ARE 45° AND 60°. Standard RCP Lateral �; 12" to 84" Diameter 1 :y�tT p SHEET NUMBER 1 JOHNSON COUNTY PIPE,INC. SCALE: NTS DR. BY: CEH JCP — MB iAn An,enann Owned Company 800 CR 209-ALVARADO,TX 76009 000X i PH.(811)783-3444 DATE 8/11/06 CK BY FAX:(817)783 6002 i is f'. i i E: It' tt� (p F. F F I I !'. I r I t QO \ /O s , / I. ., // \ iP is is i F / I F ;, i I L' I l I. t I I r. It r I: I'. Plan view ,.,.. j I i- NOTE: p 1. STANDARD ANGLES ARE 15', 30', 45' & 90°. E F: R J Standard RCP Bend ' 12" to 84" Diameter _., n SHEET NUMBER E k R. BY: CEH JOHNSON COUNTYPIPF_,INC.iNC SCALE: NTS JCP OOOX �' p A 1 J p Y I. 8 CR209 A TX 76009 ( PR:((01t)7833544 444 V-FAX:(817)7836002 DATE 06/26/09 CK BY JD - -- Jihnsofl County Ripe, n(T.::. MATERIAL SAFETY DATA SHEET for Johnson County Pipe rIW- Fi-gRF'52- 7-WARTFIEWIPP-7554-MF:MilWafalWigitaRra17377-MR5752a507-077:11WMPPOIMOVV9, A:9_t,AigfgSgair:WtTaV,)V.ig1,V)1Mi.ktiqgfgnnftntgtkitntnk1nrkgggitiatgg*Itg:ZrtgV: Material ldentit (Trade Names): Concrete Pipe and Box ______ Manufacturer's Name: Johnson County Pipe, Inc. EmergencY Telephone Number: (817)783-3444 Address: 800 CR-209 Telephone Number for Information: (8'17)783-3444 'f:VH15f;tilte-tablfitibilin-k11400111186 ,161111111-11111111111111112'NOVISSE Hazardous Components CAS OSHA ACGIH MSHA _ (Chemical Identity/Common Names) No. P EL TLV P EL Quartz(SiO2) 10mg/M3 (as free Crystalline Silica) %S02±2 % r+qtraP,I,I1PTWIFratfltSfatPNDTMN-RSESBBEWMEEWRRVFgMj .. ,-,-- --,-..1,-±,41L 4...1f---j-7PALSZ",A.,_1,-"lt, ..z,---,'--:;§PRMM:a:K-Rig-V5:F.:ig'igiltaVag-g1;2M-EitRr+WtYeia-5-Rbl'V■§gaeKXTM Boiling Point N/A Specific Gravity(H20= 1) N/A Vapor Pressure(mm Hg) N/A Melting Point N/A Vapor Density(Air= 1) N/A Evaporation (Butyl Acetate= 1) N/A Solubility in Water: Not Soluble Appearance and Odor: Odorless Solid WAITMERFAIMPIMPFESMEMORMONERZENFREFERNWROSSOROMERV Li 4gg.d,N*VjSt.tilNacgVai,MgP)'..AtVvatgaVzgtVg'ggtegPknggfjtf;iVrggRlr1MISMEMiFfatgiPVW Flash Point: Not Combustible 1Flammable Limits: Not Flammable Extinguishing Media: This material is noncombustible. Use extinguishing media appropriate to surrounding fire. Unusual Fire and ExplosionHazards:.,_None__ 1,7,,,,oF,,,:-.2.7aw,, • .7A1F-AwkivAxcgai,topwrio,isimigomyA:ini.oniTT-.772.ff. NR4-Tfrhf4tFf4e.gr4gStNtgqaabraittghi9.,:,.T:,-,: tt,-,-=::,k5imzti,t:iqog.wa,:.,,,4,,E::,g4::;t:p,.;;F.r.4,,z,;%,up:20:, ,:r:krg;i2_,w,--!,,A,R-er.to. i2g4421L-A,arktrie2J.,:a.gligitageWMON.MagaitaraMiTtVgantffirIgIMAVAIMAEVETR-201 Stability: Unstable Conditions to Avoid: None Incompatibility(Materials to Avoid): None Hazardous Decomposition or Byproducts: None Hazardous Polymerization: Not known to occur '''TaraiMMTN-V-AVIMAIMARAIRWOWISMAMAIWATKOTIE457CRIFORTASMOIRIRIMAWFIX-WWWIA OteariatittOVAIMONSMOVARAIMEMENSOROMMESEMORM Route(s)of Entry: Inhalation? yes Skin? no Ingestion? yes ...._ Health Hazards: Sawing or grinding may result in release of dust particles which may cause minor irritation of the eyes or nose. Chronic Effects: Result in lung disease (Silicosis) if exposed to excessive amounts for prolonged periods. Page 1 of 2 �" x Carcinogenicity: NTP IARC Monographs OSHA Regulated no no -- no -- Signs and Symptoms of Exposure: Irritation of the eyes and nose, shortness of breath. -- Medical Conditions Generally Aggravated by Exposure: Pre-existing lung disease such as Emphysema or Asthma. Emergency and First-Aid Procedures: Eyes: Flush eyes generously with water for 15 minutes. If irritation persists, contact a physician. Inhalation of Dust: Remove exposed person to fresh air and support breathing as needed. Consult a physician immediately if irritation persists _.,`' F ..Wr477,1 si b �- '.-- s"" _ 0 i 3 ti -�i jJ'.y a F ` .�.." - `."f g, .._i Steps to Be Taken in Case Material is Released or Spilled: Sweep up and discard. Waste Disposal Method: Dispose of as common waste. Precautions to Be Taken in Handling and Storing: None Precautions Wear NIOSH Q�t((�� . .L 'M1• approved respirator r and tight fi..�inggogglees when sawing or grinding.rr . ' r � tttx j e - S r C•' 61-t�y a� MY a tt3 a_. a t - . i a . " - _ J-- Resiratory Protection: NIOSH approved particulate respirator. Ventilation: Local Exhaust: —Other: -- Mechanical (General): In confined area. Special: —___-- Skin Protection: Eye Protection: Tight fitting safety goggles. Other Protective Clothing or Equipment None _ — — --- —Work/Hygienic Practices: N/A --- — -"- Disclaimer: The information contained in this Material Safety Data Sheet is based on technical data that the company believes to be accurate. Page 2 of 2 v! p m . Tar y p 6p@ ty®� 1 il o POLYMllU1 MODIFIED COACEET , JOINT SEAL6#TA°ii �l d jl. „ Evergrip 990 is a concrete joint sealant made with a unique blend of -' asphalts enriched with high grade polymer.Available in convenient strips,Evergrip 990 is a preformed,ready-to-use,flexible gasket that r, u i > ' a '' 04. i provides an n excellen t seal for c o ne ere pipes,ipes,culver ts,manholes oles and K 'I.y t ` �F 01AY I elf ,c j " 4p i other p ecast cone ere joints S [r 1 K „aI } � V c �`ry a � la (1 1^t wr. i s 1 — fJ .'Y $ . - 9 � - .0. _ � °' U ,6- 25- ~ ' S� 3 t ° t� S 7 1 •? ' - . 4 : f � t ra . .m = 3▪ 21, rr (,'.6. 4 � "'s ,rkww ' j4 r to, A polymer modified sealant,Evergrip 990 offers si g nificant x ) d ti r p ,' t i Y l 79 � ' ti 4 ? j advantages } advanta es over non-modified sealants: . ` 1 ��� ! t 41r • -1 3 • 60%more adhesive strength ),•,;,. rt �i fiM , t f �e 5-67b 0rep iipS,Ii • 366%more cohesive strength 0 i t t •Greater elasticity em s [ xy lD�yi: •40%higher ductility Fc yflut rqt I I J. , f ° Consistent performance over a wider range of temperatures ' IE91 El°�x l."°, y r f pal- �_cxlrn i 6 r t:,,rent c s � >,, I Pi �� ' k,�Fq-� i 1 • Provides watertight seal I~+'+''+: jrt�F'04 •For concrete joints of all sizes and shapes f. k ii ° Extruded strips for easy application 'Available in standard sizes and lengths + pt d Inr1 Y4 drlc.I tvx,L, ,nl c, IS d t}' ts.--- 1 •Asbestos free (i"SrC �l 1 1tit •Odorless 1F x 7 x"�" ' ` L x • 100%solids LIT } ° No primer necessary 1 ,z�� No shrtnlcage E U E 1 G R I P 9 9 0 STRIPS W t —i'-k5f=TclAl1D ra A7R U„ $MFtjv ' 3 I A,a6l�:z ltaa a(aml svi-:14Fn tia- . tur ,+Ps.k• .t, r.._ ti rya x POLYMER MODIFIED CONCRETE JOINT SEALANT ;; Evergrip 990 meets or exceeds all requirements of ASTM C 990, pU.S.Federal Specifications SS-S-210A,Type ',Rope Form and AASHTO Designation M-198 75 !,Type B.Certified to meet or f exceed highway department specifications. ri e.-1W L.:,' a }jK ,...q..0.--,:.17 y��J,, Zep41 z.�. � y�H �.'�. '£N 'r.S ..1'l. _la:J. :9 1»-.:.'.3 f'... Concrete surfaces to which sealant is to be applied must be clean •° -1 and dry.Remove all mud,dirt,grease,oil and loose particles. ij • ° Remove release paper from one side of sealant.Leave the outside paper in place to protect the sealant from contamination and i stretching.Attach the sealant end to end to the leading edge of the A B A B 1 tongue or groove of each pipe joint until a continuous gasket is u established around the entire circumference of the pipe joint.Press material firmly into place through the outside paper.Remove the outside paper just prior to jointing the pipe.Avoid contaminating the exposed sealant with any foreign materials.Any contaminated sealant should be removed and replaced.Do not disturb the gasket A) Sealant Placement N < ,Yy, m. 6) Joint After Compression CI,IIF :STATES ASPHALT CO ILLr 41 l j'l I 15.0..;,;,WQ �r ` yN s s 7 7tl�:l `^11 I1;;pjr llSl curl rs+; } :Vg , j'�f«ph?nr,i;l3O €tti I tl r P. J POLYMER MOOKFREII CONCRETE JOINT SEALI1NT Irt i I r S \ i" \. I placement.Any displaced sealant should be repositioned prior to _ ._.,.W:,... ,:.,,:.:y. ...�., jointing the pipes. �p i„.„+� jj sitt Peo,,,FA. r.y5ARe E Read pipe manufacttn•er's instructions for proper pipe jointing pr•oce- dures,The trench can be hackfilled as soon as the joining process has SEALANT SIZE PIECESICARTON FT./CARTON been completed. 314”x 2'6" 50 125 it eiPiilfa;� Q�t 'M7�4;TllnWr;``;.;..: .-,".4_!';. r .`' ��f 1.1 Y is--F' ...r?3G- s, -.... ... itv i9. x_ gar_e3 .fl- I„x2,6,. 35 87.5 ft g I”x 3'6" 35 122.5 ft 5 Conditions must preclude contamination of the sealant during the I 1/4"x 3'6" 28 98 ft F installation process by any foreign material such as silt or mud. 1 112"x 3'6" 20 70 ft 6 314"x 3'6" 13 45.5 ft :• IT 4#CAG g � __„rte 1'!- �„,,,TA,.ivvs” mvrL; --,���'� r 2"x 3'6" 10 35 ft 1 Store in a dry area protected from the elements.Do not stack car- tons over six high SEALANT SIZE N M/CARTON k r7 llllP VI •' -,.. s t a : CARTON 47a, c C _tY t,i Z -1 t �,} � f 2 -4,s di,a h ` Scrape excess sealant off surfaces,Asphalt stains can be removed 19mm x 762mm 50 38.1 m with non-hazardous,bio-degradable cleaners.Use waterless hand 25.4mm x 762mm 35 26.7m 1 cleaner on skin.Follow cleaner manufacturer's instructions carefully. e 25.4mm x 1067mm 35 37.3m a Do not use flammable or combustible petroleum based solvents. 31.75mm x 1067mm 28 29.9m 38.1 mm x 1067mm 20 21.3m u 44.45mm x 1067mm 13 13.9m t 50.8mm x I067mm 10 10.7m .1.3 -urn �a� ,-,1'q 1.,r,Er r;. � '.0 '+.° '� t a , -t , t i-". a t-a. 4rar +�.� , `�i' k;:i'�C�}e }yneiglA ¢e c. �: f.%,,,1 to--4AU oN14,�- _-TES 1-1 V-1- ,'d. Bitumen,%by wt. 50-70 Inert filler content,%by wt. 30-50 Volatile matter,inax.%by wt. 2.0 1 .r t F. 1W �"� , d .W ' w '.•, a r ,r4. :sa 1,y-- - _ ;FA= `, r ,4, f� 0- S,..m h t �t s -e.1, n -t k ..!ap T�I,E:.a1. _:� � tr -� .,!6 'ig' „4.3..... a, `; :._ Specific gravity @ 77'F125°C,(gr/m1) 1.2-1.35 Ductility @ 77°F/25°C,(cm),min. 5.0 Min.softening point 320°F/160°C Min.flash point,C.O.C. 600'F/315°C Fenetration @ 77°F125°C, ISO gams,5 sec.(dmm) 50-12.0 Adhesion and hydrostatic pressure No leaks(24 hrs.) Sag or flow resistance No sagging Chemical resistance No visible deterioration ` Read and understand MSDS sheet before use. . ..-.._... T:.._ .*, P NA A ,1G C'I@., L.P. 4 - ; ��ttt� C'f ,itlZ x7,71 1 „ I S tl 11.5 qE ` 41 lIIriflatS71:p1 s 5�_a7 5 a t �1 1I mpl1:[r.;l-[fib t;z,r•rl ri ;, �,. I A''''' '' ohitiiiir l‘ti A larillinalli °,1 6 B PLAN VIEW ISOMETRIC VIEW A B ---8---- 1 1 6 I 6 2 ///1 \\\N j F 1 1 1 °1 6 - C — 51DE ELEVATION FKONT ELEVATION 902- fe PIPE I.D. 18" 24" 30" 36" 01I- A 35" 42" 49" 56" 5/,�6 �° J{{�� 5 24" 36" 60" 60" C 48" 09" III" I 1 1.50" 1049 Highway 287 0 30" 36" 41" 60" The Turner Company Rhome,Tx76078 E 7. 9.. 7 6 (517)635-9053 F I8" 18" 16" 18" 1 u 8" I.D. HEADWALL G 30" 29" 27" 30" Concre e: WEIGHT 2170 40004965 6700 IN LBS. 4,500 PSI MIN. - 28 DAY STRENGTH Reinforcement: SEE CHART FOR ADDITIONAL Size: Date: DWG No. SIZES AND SPECIFICATION5 Weight: 2 170Ibs