Loading...
Tax 2011B-LR130305ALUAncE cEoTEcHrncAL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 02/04/2013 Report Date: 03/05/2013 Previously Reported: 02/06/2013 Sampled By: Smith, Courtney Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: Vanbebber Drive Order Number: 1770 Client: City of Coppell REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 141892 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 141892 Page 1 of 2 Set: 1 of 2 Material: CONCRETE Number of Specimens: 5 Location: Vanbebber Drive entrance to Shell Gas Station, station 4 +00 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (lbs) Break Type Loc (PSI) (PSI) By Comments A 02/05/13: 1 6.00 28.27 66,220 Type 2 Lab 2,340 2,340 B 02/11/13: 7 6.00 28.27 111,220 Type 2 Lab 3,930 C 02/11/13: 7 6.00 28.27 109,735 Type 2 Lab 3,880 3,910 D 03/04/13: 28 6.00 28.27 168,400 Type 3 Lab 5,960 E 03/04/13: 28 6.00 28.27 169,300 Type 3 Lab 5,990 5,970 R11`79 RR IU R FIE [_] Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 02/05/2013 Curing Method: Standard Time Sampled: 11:30 am Time Batched: 10:30 am Temp.: Ambient: 63 °F Mix: 68 °F CONFORMS Slump: 2.0 Inches Transported By: TXI Air Content: 4.0% Source /Sampled At: Truck / Center Mix Code: 8274 Plant: TXI - Plant #141 Truck /Ticket No: 8060 / 1596752 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 150 cu. yd. total placement Remarks: *Slump below specifications Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. f1LLlftt'ICE kGF_0_TECHri1Cf1L Q30UF' Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 02/04/2013 Report Date: 03/05/2013 Previously Reported: 02/06/2013 Sampled By: Smith, Courtney Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: Vanbebber Drive Order Number: 1770 Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 141892 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 141892 Page 2 of 2 Set: 2 of 2 Material: CONCRETE Number of Specimens: 5 Location: Vanbebber Drive, station 19 +00, N.bound side Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 02/05/13 :1 6.00 28.27 88,215 Type 2 Lab 3,120 3,120 B 02/11/13: 7 6.00 28.27 131,045 Type 2 Lab 4,630 C 02/11/13: 7 6.00 28.27 127,860 Type 2 Lab 4,520 4,580 D 03/04/13: 28 6.00 28.27 146,856 Type 4 Lab 5,190 E 03/04/13: 28 6.00 28.27 160,365 Type 3 Lab 5,670 5,430 RX ............. 1- 11E1 [71 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 4,000 psi @ 28 days Slump: 1 - 3 Air Content: 3 - 5 Date Received: 02/05/2013 Curing Method: Standard Time Sampled: 2:40 pm Time Batched: 1:44 pm Temp.: Ambient: 64 °F Mix: 68 °F CONFORMS Slump: 3.0 Inches Transported By: TXI Air Content: 3.5% Source /Sampled At: Truck / Center Mix Code: 8274 Plant: TXI - Plant #131 Truck /Ticket No: 1511 / 1597119 Quantity Represented: 10 cu. yds. at 80 cu. yds. placed of a 150 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Per C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.