Dear Mr. Goodwin:
The City of Coppell has reviewed the referenced plans and has the following comments to
offer:
1. Show adjacent streets and nearby streets across Sandy Lake Road.
2. Label sheets 2 and 3 as paving plan or similar.
3. The asphalt transition to Sandy Lake Road will need to meet the requirements of the
Subdivision Ordinance.
4. Show all sidewalks with ADA ramps at intersections and shade to designate which
sidewalks will be built with streets and which sidewalks will be built by homebuilder.
The curb inlets on Castlebury Court near Sandy Lake Road may need to be moved to the
south to make room for ADA ramps.
5. Extend concrete paving to right-of-way line and show an 8' brick paver band on the
paving plan at the intersection with Sandy Lake Road.
6. Provide inlets to pick up drainage from the alley to Castlebury Court and show the alley
warped to drain to inlets.
7. Use City of Coppell Standards for alley paving and headwall details.
8. Show existing grade at the back of Lot 11.
9. Provide some information regarding any drainage structure/channel located in the 5'
drainage easement at the northeast comer of the property.
10. Show the proposed grade on the storm drain profiles.
11. Verify the depth of bore across Sandy Lake Road and the depth of utilities to avoid any
conflict with the Sandy Lake Road reconstruction.
12. Provide some detail as to the alignment/construction of the 27" RCP under Castlebury
Court along Sandy Lake Road. How will you grade the ditch next to the existing 24"? Do
you have enough clearance to construct a beadwall? Provide a detail how the proposed
system will be connected to the proposed Sandy Lake Road system.
13. Provide an 8~ water line smbout to the west located between Lot 7 and Lot 8. Also,
reconfigure the end of the proposed water line and show a blow-off valve on the end of
the line. A 20' easement will be required between the lots.
14. Indicate the size of the residential water meters on the water layout plan.
There are various other minor comments throughout the plans. When all comments have been
addressed, please return these marked plans and two sets of revised plans to the City for
review. If you have any questions, please contact me at (972) 304-7019. ,
Sincerely,
Kent M. Collins, E.I.T.