Loading...
Tax 2011B-LR130306�flU.IMCE GE07'ECtilYlC19L C#nQUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 02/05/2013 Report Date: 03/06/2013 Previously Reported: 02/11/2013 Sampled By: Smith, Courtney Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: Vanbebber Drive Order Number: 1770 Client: City of Coppell REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 141945 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 141945 Page 1 of 2 Set: 1 of 2 Material: CONCRETE Location: Vanbebber Drive, station 17 +00 Spec Age Tested Diameter Nbr (date : days) (in) A 02/08/13:3 6.00 B 02/12/13:7 6.00 C 02/12/13:7 6.00 D 03/05/13:28 6.00 E 03/05/13:28 6.00 Number of Specimens: 5 Maximum Compressive Average Area Load Cure Strength Strength Tested (in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments 28.27 103,415 Type 5 Lab 3,660 3,660 28.27 112,030 Type 2 Lab 3,960 28.27 111,545 Type 2 Lab 3,950 28.27 142,890 Type 2 Lab 5,050 28.27 150,130 Type 2 Lab 5,310 I DE1 Type 1 Type 2 Type 3 Type 4 Type 5 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 02/06/2013 Curing Method: Standard Time Sampled: 10:30 am Time Batched: 9:40 am Temp.: Ambient: 62 °F Mix: 65 °F CONFORMS Slump: 4.75 Inches Air Content: 6.0% Mix Code: 8274 3,950 5,180 �.. ^pli Type 6 Transported By: TXI Source /Sampled At: Truck / Center Plant: TXI - Plant #131 Truck /Ticket No: 1518 / 1598026 Quantity Represented: 10 cu. yds. at 40 cu. yds. placed of a 120 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kak ra, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR 00 THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. fiLLIH17CE GECITECHIYlCRL QiOUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C12 -1001 Date Sampled: 02/05/2013 Report Date: 03/06/2013 Previously Reported: 02/11/2013 Sampled By: Smith, Courtney Project: Vanbebber Drive Street Improvements By Order Of: Chris Location: Vanbebber Drive Order Number: 1770 Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 141945 Test Method: See Below Client PO: Q- 0612 -01 TEST RESULTS Report No: 141945 Page 2 of 2 Set: 2 of 2 Material: CONCRETE Location: Vanbebber Drive, station 18 +50 Spec Age Tested Diameter Nbr (date : days) (in) A 02/08/13:3 6.00 B 02/12/13:7 6.00 C 02/12/13:7 6.00 D 03/05/13:28 6.00 E 03/05/13:28 6.00 Number of Specimens: 5 Maximum Compressive Average Area Load Cure Strength Strength Tested (in 2) (lbs) Break Type Loc (PSI) (PSI) By Comments 28.27 104,305 Type 5 Lab 3,690 3,690 28.27 126,935 Type 5 Lab 4,490 28.27 124,520 Type 5 Lab 4,400 4,450 28.27 162,030 Type 3 Lab 5,730 28.27 152,290 Type 3 Lab 5,390 5,560 'DI'l l . � k [71 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 4,000 psi @ 28 days Slump: 3 - 5 Air Content: 3 - 6 Date Received: 02/06/2013 Curing Method: Standard Time Sampled: 12:50 pm Time Batched: 12:00 pm Temp.: Ambient: 64 °F Mix: 63 °F CONFORMS Slump: 5.0 Inches Transported By: TXI Air Content: 5.0% Source /Sampled At: Truck / Center Mix Code: 8274 Plant: TXI - Plant #142 Truck /Ticket No: 3027 / 1598369 Quantity Represented: 10 cu. yds. at 100 cu. yds. placed of a 120 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.