Loading...
Villas at LV 2-LR130219 REPORT OF FIELD COMPACTION TESTS 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 II Geotechnical Construction Materials Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR:JBGL BF Development LLCDATE: 02/19/13 Dallas, Texas PROJECT:OUR REPORT NO.:121732-37 Villas at Lake Vista Phase 2 - Utilities and Paving Coppell, Texas TEST DATA:TECHNICIAN:Travis Alvarez MAXIMUM LABIN PLACEIN PLACE OPTIMUM TESTSOIL ID ELEV. PERCENT DATE COMMENT* MOISTUREDRY DENSITYMOISTUREDRY DENSITY NO.NUMBER COMPACTION DEPTH %PCF%PCF 12602/19/13456.74121535/321.298.322.894951-A 12702/19/13457.04121535/321.298.322.297991-A 12802/19/13457.24121535/321.298.321.696971-A 12902/19/13257.54121535/321.298.323.597991-A 13002/19/13457.64121535/321.298.322.696981-A TEST LOCATION:Levee Repair 126Block A, Pad 36 127Block A, Pad 37 128Block A, Pad 38 129Block A, Pad 39 130Block A, Pad 40 1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted, 4. CEMENT TREATEDD. RETEST Bulent Ethem, P.G. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.