Date Sampled: 02/11/2013
Report Date: 03/12/2013 Previously Reported: 02/15/2013
Sampled By: Burgdorf, Bradley
Project: Vanbebber Drive Street Improvements
By Order Of: Chris
Location: Paving, Heartz Rd at Vanbebber intersection
Order Number: 1770
Number of
Client: City of Coppell
Specimens: 5
REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
LAB NO: 142159
Material: CONCRETE
Test Method: See Below
Client PO: Q- 0612 -01 TEST RESULTS
Report No: 142159
Page 1 of 1
Maximum
Compressive
Average
Spec Age Tested Diameter Area Load
Cure
Strength
Strength Tested
Nbr (date : days) (in) (in 2) (Ibs) Break Type
Loc
(PSI)
(PSI) By Comments
A 02/13/13: 2 6.00 28.27 93,535 Type 2
Lab
3,310
3,310
B 02/18/13: 7 6.00 28.27 146,995 Type 2
Lab
5,200
5,200
C 03/11/13: 28 6.00 28.27 183,905 Type 3
Lab
6,500
D 03/11/13: 28 6.00 28.27 187,910 Type 3
Lab
6,650
6,580
E HOLD (see remarks) - 1`721 R P [U R
Type 1 Type 2 Type 3 Type 4 Type 5 Type 6
Specification CONFORMS
Strength: 4,000 psi @ 28 days
Slump: 3 - 5 Slump: 3.75 Inches Transported By: TXI
Air Content: 3 - 6 Air Content: 4.6% Source /Sampled At: Truck / Center
Mix Code: 8274 Plant: TXI - Plant #131
Date Received: 02/12/2013 Truck /Ticket No: 1574 / 1603536
Curing Method: Standard
Time Sampled: 9:15 am
Time Batched: 8:15 am
Temp.: Ambient: 62 °F Mix: 61 °F
Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or
C173, C1064 and C138. Compressive strength tests per ASTM C39.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.