COS Lutheran-CS 890808 INN, INC. City of Cfippell P.O. Box/478 Coppel~ TX 75019 Re: P.Eo CONSULTING ENGINEERS Christ Our Savior Lutheran Church Heartz Road Grading, Drainage and Utility Plan Dear Mr. Doyle: We received plans for the above referenced project late Friday, August 4, 1989, with a request to return comments by Monday or Tuesday of this week. In our cursory review of the plans, we have the following comments. The 6" sanitary sewer line, within the right-of-way should be 8" diameter. In looking at the profile we can see potential conflicts with going under the 8" waterline and over the 42" RCP. To help alleviate potential problems, a suggestion would be to not allow any joints in the sanitary sewer main to be within 10' of the waterline crossing, plus extend the concrete encasement 10' beyond the RCP as well as the 8" water main. From the grades shown, it appears that there is only a little over 1" clearance between top of 42" RCP and bottom of sanitary sewer line. Engineer should provide concrete replacement detail for Heartz Road. Suggest providing double clean-out at property line on sanitary sewer line. Two standard 10' curb inlets at rear of property, each designed to carry 16.56 c.f.s., may not be adequate. Local flooding of those areas may occur. e Sanitary sewer profile calls for ductile iron pipe, Class 51, while note #10 proposes use of PVC, DR 35. The removal and replacement of concrete pavement for storm sewer tie-ins, water main tap, and sanitary sewer main should be coordinated with City Inspector. Suggest that "trench widths" of concrete replacement should not be allowed, but that concrete sections, located at existing joints, should be removed and replaced. 17103 Preston Road · Suite 100 · LB 118 · Dallas, Texas 75248 · Phone 214/248-4900 Paving notes indicate 5" thickness to be used. City requires 6" minimum thickness, unless a variance has been granted. Should you require any further information, please do not hesitate to contact us. Sincerely, Gabe Favre GF/dsp CC: Ben dela Cruz Hennessey Engineers H. Wayne Ginn, P.E. John C. Karlsruher, P.E. File 89305