Loading...
Villas at LV 2-LR121219 Alpha Testing, Inc. 2209 Wisconsin St.,Suite 100 Concrete Compression Test Dallas,TX 75229 (972)620-8911 Report TBPE Firm No.813 Tested For: JBGL BF DEVELOPMENT LLC Our Report No.: 121732-2 ATTN: SCOT WHITWER 3131 HARVARD AVE.,SUITE 103 PM: BULENT ETHEM,P.G. DALLAS,TX 75205 Fax Number: (214)383-1117 Project Desc:VILLAS AT LAKE VISTA PHASE 2-UTILITIES&PAVING SE OF MACARTHUR BLVD.&LAKE VISTA DRIVE FIELD DATA Placement Location: SIDEWALK ALONG LAKE VISTA DR. Sample Location: 10'N OF 1ST SECTION OF SIDEWALK ON WEST SIDE Date Placed: 11/21/2012 Plant Number: 955 Time Placed: 9:45 AM Delivery Ticket No.: 64333189 Slump(ASTM C-143): 3.5 Mix ID: 1261 Air Content: N/A Made By: ALPHA Air Temperature: 53 Specimen Temperature: 65 Cured Specification: ASTM C-31 Date Received: 11/22/2012 Field Data Submitted By: Villegas,Julian Mix Data Submitted By: LMC CYLINDER COMPRESSION TEST RESULTS Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI: 1 LAB C-1231 11/28/201 7 8 N/A 4 12.56 45590 3630 2 LAB C-1231 12/19/201 28 8 N/A 4 12.56 59390 4730 3 LAB C-1231 12/19/201 28 8 N/A 4 12.56 59720 4750 4 LAB HOLD HOLD 8 N/A 4 12.56 0 Specifications: 28 3000 Results to Date: PASS CC: GM Construction Respectfully Submitted By: of Alpha Testing,Inc. Test Method:Unless noted,concrete was sampled and tested in accordance with ASTM C172,C143,C231,C173,C1064 AND C138.Compression strength tests per ASTM C39. Our test results and reports are for the exclusive use of the Client(and their designated recepients on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed,and are not indicative of the qualities of apparently identical or similar specimens. 'A T r7"((1�i 1:` }S °r a ) (r w s 1 .it }i"r ' k''�s 1