Villas at LV 2-LR121231 X Alpha Testing, Inc.
•J
2209 Wisconsin St., Suite 100 Concrete Compression Test
Dallas,TX 75229
(972)620-8911 Report
TBPE Firm No.813
Tested For: JBGL BF DEVELOPMENT LLC Our Report No.: 121732-12
ATTN: SCOT WHITWER
3131 HARVARD AVE.,SUITE 103 PM: BULENT ETHEM,P.G.
DALLAS,TX 75205
Fax Number: (214)383-1117
Project Desc:VILLAS AT LAKE VISTA PHASE 2-UTILITIES&PAVING
SE OF MACARTHUR BLVD.&LAKE VISTA DRIVE
FIELD DATA
Placement Location: INLETS ON LAKE VISTA DR.
Sample Location: INLET BOTTOMS
Date Placed: 12/3/2012 Plant Number: P259
Time Placed: N/A Delivery Ticket No.: 25580137
Slump(ASTM C-143): N/A Mix ID: 10L11504
Air Content: N/A Made By: CONTRACTOR
Air Temperature: N/A
Specimen Temperature: N/A Cured Specification: ASTM C-31
Date Received: 12/4/2012
Field Data Submitted By: CONTRACTOR
Mix Data Submitted By: REDI MIX
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI:
5 LAB 5 C-1231 12/10/201 7 8 N/A 4 12.56 56120 4470
6 LAB C-1231 12/31/201 28 8 N/A 4 12.56 62180 4950
7 LAB C-1231 12/31/201 28 8 N/A 4 12.56 63580 5060
8 LAB HOLD HOLD 8 N/A 4 12.56 0
Specifications: 28 4000
Results to Date: PASS
CC: GM Construction
Respectfully Submitted By: of Alpha Testing,Inc.
Test Method:Unless noted,concrete was sampled and tested in accordance with ASTM C172,C143,C231,C173,C1064 AND C138.Compression strength tests per
ASTM C39. Our test results and reports are for the exclusive use of the Client(and their designated recepients on file in our office)and shall not be reproduced and/or
distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the
samples tested and/or observed,and are not indicative of the qualities of apparently identical or similar specimens. g
r`.. c. n ,` 0 f,1 aI ,h0si er fw-p`>,...¢"...t„iSl°f(/' T, ::4,03 ■_ i. all -�i iit t 1.'_.:" ,,. ti. ,.v � .E •, "St