Villas at LV 2-LR130118 (2) X Alpha Testing,Inc.
2209 Wisconsin St.,Suite 100 Concrete Compression Test
Dallas,TX 75229
(972)620-8911 Report
TBPE Firm No.813
Tested For: JBGL BF DEVELOPMENT LLC Our Report No.: 121732-19
ATTN: SCOT WHITWER
3131 HARVARD AVE.,SUITE 103 PM: BULENT ETHEM,P.G.
DALLAS,TX 75205
Fax Number: (214)383-1117
Project Desc:VILLAS AT LAKE VISTA PHASE 2-UTILITIES&PAVING
SE OF MACARTHUR BLVD.&LAKE VISTA DRIVE
FIELD DATA
Placement Location: PAVING,SNOWSHILL TRAIL FROM STATION 2+54.56 TO 5+80
Sample Location: @ STATION 3+00
Date Placed: 12/21/2012 Plant Number: 955
Time Placed: 9:05 AM Delivery Ticket No.: 64334810
Slump(ASTM C-143): 2.25 Mix ID: 1701
Air Content: 5.0 (ASTM C-231) Made By: ALPHA
Air Temperature: 37
Specimen Temperature: 55 Cured Specification: ASTM C-31
Date Received: 12/22/2012
Field Data Submitted By: Cranford,Jimi
Mix Data Submitted By: LMC
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI:
25 LAB C-1231 12/28/201 7 8 N/A 4 12.56 69640 5540
26 LAB C-1231 1/18/2013 28 8 N/A 4 12.56 73420 5850
27 LAB C-1231 1/18/2013 28 8 N/A 4 12.56 77930 6200
28 LAB HOLD HOLD 8 N/A 4 12.56 0
Specifications: 28 3600 I
Results to Date: PASS
CC: GM Construction
Respectfully Submitted By: of Alpha Testing,Inc.
Test Method:Unless noted,concrete was sampled and tested in accordance with ASTM C172,C143,C231,C173,C1064 AND C138.Compression strength tests per
ASTM C39. Our test results and reports are for the exclusive use of the Client(and their designated recepients on file in our office)and shall not be reproduced and/or
distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the
samples tested and/or observed,and are not indicative of the qualities of apparently identical or similar specimens.
z . ' 1a..-I nSgine ring*Const'uc J t r., 670.a *`Y(4 j" e hg'C �g . :=!096
X ,,-----/
Alpha Testing, Inc. �--
2209 Wisconsin St., Suite 100 Concrete Compression Test
Dallas,TX 75229
(972)620-8911 Report
TBPE Firm No.813
Tested For: JBGL BF DEVELOPMENT LLC Our Report No.: 121732-20
ATTN: SCOT WHITWER
3131 HARVARD AVE.,SUITE 103 PM: BULENT ETHEM,P.G.
DALLAS,TX 75205
Fax Number: (214)383-1117
Project Desc: VILLAS AT LAKE VISTA PHASE 2-UTILITIES&PAVING
SE OF MACARTHUR BLVD.&LAKE VISTA DRIVE
FIELD DATA
Placement Location: PAVING,SNOWSHILL TRAIL FROM STATION 2+54.56 TO 5+80
Sample Location: @ STATION 5+00
Date Placed: 12/21/2012 Plant Number: 952
Time Placed: 10:55 AM Delivery Ticket No.: 62941589
Slump(ASTM C-143): 2.5 Mix ID: 1701
Air Content: 4.8 (ASTM C-231) Made By: ALPHA
Air Temperature: 45
Specimen Temperature: 57 Cured Specification: ASTM C-31
Date Received: 12/22/2012
Field Data Submitted By: Cranford,Jimi
Mix Data Submitted By: LMC
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI:
29 LAB C-1231 12/28/201 7 8 N/A 4 12.56 59880 4770
30 LAB C-1231 1/18/2013 28 8 N/A 4 12.56 75810 6040
31 LAB C-1231 1/18/2013 28 8 N/A 4 12.56 79750 6350
32 LAB HOLD HOLD 8 N/A 4 12.56 0
Specifications: 28 3600 I
Results to Date: PASS
CC: GM Construction
Respectfully Submitted By: of Alpha Testing,Inc.
Test Method:Unless noted,concrete was sampled and tested in accordance with ASTM C172,C143,C231,C173,C1064 AND C138.Compression strength tests per
ASTM C39. Our test results and reports are for the exclusive use of the Client(and their designated recepients on file in our office)and shall not be reproduced and/or
distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the
samples tested and/or observed,and are not indicative of the qualities of apparently identical or similar specimens.
• . Mrfe"t n 3Jee ng f Co rst uct,o a a1 . .t,. ;t it le !e tngI t`rosin 14697