Coppell Ind 2-LR130403REEL7 EI-IG I I - IEEFRIMES GEOTECHNICAL AND G R O LJ P ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Tradepoint Center II Creekview Road & Freeport Parkway Coppell, Texas REPORTED TO: Hillwood 3090 Olive Street, Suite 300 Dallas, Texas 75219 ATTN: Mr. Kerry Roetzel CONTRACTOR: Hillwood Construction Services Location of Sarnme REPORT NO. 325 REG PROJECT NO. 18520 SAMPLE DATE: 03 -27 -13 TECHNICIAN: A. Chavez PAGE: 1 of 2 Set Number Cylinder ID Location I Quantity Represented (c. y.) 1 West half parking: G.5/12, 110'W 30/443 2 West half parking: G.8/12, 75'W 130/443 3 West half parking: F.1/12, 65'W 230/443 4 West half parking: E/12, 185'W 320/443 5 West half parking: C.2/12, 90'W 410/443 Design Information Source of Concrete Mix Identification specified strength (psi) Potter Ready Mix 7752TP 4000 Test Results Set No. Cylinder ID Date Tested Age @ Test Total Load lbs. Compressive Strength (psi) Average Strength (psi) 1 5598 04 -03 -13 7 139490 4940 5598 04 -24 -13 28 5598 04 -24 -13 28 5598 Hold H 2 5599 04 -03 -13 7 145670 5150 5599 04 -24 -13 28 5599 04 -24 -13 28 5599 Hold H 3 5600 04 -03 -13 7 148300 5250 5600 04 -24 -13 28 5600 04 -24 -13 28 5600 Hold H 4 5601 04 -03 -13 7 104880 3710 5601 04 -24 -13 28 5601 04 -24 -13 28 5601 Hold H 2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAx [214] 350 0019 REPORT NO. 325 REG PROJECT NO. 18520 SAMPLE DATE: 03 -27 -13 PAGE: 2 of 2 Test Results Set Cylinder I Age @ Total Load Compressive Average Strength No. ID Date Tested Test lbs. Strength (psi) (psi) 5 5602 04 -03 -13 7 92210 3260 5602 04 -24 -13 28 5602 04 -24 -13 28 5602 Hold H Cvlinder Data Note: (1) Concrete was sampled in accordance with ASTM C -31 (2) Concrete cylinders were tested in accordance with ASTM C -39 E -Mail Submitted by: Air Concrete Air Unit Mr. Gary Jones Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket No. ID (inches) Sample ( °F) ( °F) ( %) (lbs /ft3) Number 1 5598 5.0 4:15 AM 52 62 5.8 149.2 32816 2 5599 4.75 5:45 AM 42 58 5.1 142.4 32826 3 5600 4.75 7:00 AM 35 57 5.5 143.6 32836 4 5601 5.0 8:00 AM 40 54 5.3 144.0 32845 5 5602 5.0 9:30 AM 42 58 4.6 147.6 32854 Note: (1) Concrete was sampled in accordance with ASTM C -31 (2) Concrete cylinders were tested in accordance with ASTM C -39 E -Mail Submitted by: Distribution: (1) Hillwood /Mr. Kerry Roetzel (1) Hillwood Construction Services/ REED ENGINEERING GROUP, LTD. Mr. Gary Jones Registration Number F -3114 (1) Halff Associates/ Mr. Stephen Crawford (1) Halff Associates /Mr. Lance Clinton (1) Macgregor Associates/ Mr. Thomas Holland Bill Woolwine (1) Macgregor Associates/ Sr. Manager, CMT Mr. Lee Rader BW /cn (1) City of Coppell /Mr. Lee Stone (1) City of Coppell /Mr. Michael Arellano (1) City of Coppell /Mr. Rick O'Dell (1) Ms. Sacha Miner REEL7 EI-IG I r1EEFRIMES GEOTECHNICAL AND G R O LJ P ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Tradepoint Center II Creekview Road & Freeport Parkway Coppell, Texas REPORTED TO: Hillwood 3090 Olive Street, Suite 300 Dallas, Texas 75219 ATTN: Mr. Kerry Roetzel CONTRACTOR: Hillwood Construction Services REPORT NO. 254 REG PROJECT NO. 18520 SAMPLE DATE: 03 -06 -13 TECHNICIAN: J. Bowers PAGE: 1 of 1 - ocation of Sample Set Number Location Quantity Represented (c.y.) 1 Inlet bottom & walls: Storm Lateral A -413 STA 1 +34 10/10 )esign Information Source of Concrete Mix Identification Specified Strength (psi) Red i Mix 101-11524 4000 Test Results Set No. Cylinder ID Date Tested I Age @ Test Total Load lbs. Compressive Strength (psi) Average Strength (psi) 1 5072 03 -13 -13 7 61000 4850 5072 04 -03 -13 28 81260 6470 5072 04 -03 -13 28 78700 6260 5072 04 -03 -13 28 79330 6310 6350 5072 Hold H Cvlinder Data Note: (1) Concrete was sampled in accordance with ASTM C -31 (2) Concrete cylinders were tested in accordance with ASTM C -39 E -Mail Distribution: (1) Hillwood /Mr. Kerry Roetzel (1) Hillwood Construction Services/ Mr. Gary Jones (1) Halff Associates/ Mr. Stephen Crawford (1) Halff Associates /Mr. Lance Clinton (1) Macgregor Associates/ Mr. Thomas Holland (1) Macgregor Associates/ Mr. Lee Rader (1) City of Coppell /Mr. Lee Stone (1) City of Coppell /Mr. Michael Arellano (1) City of Coppell /Mr. Rick O'Dell (1) Ms. Sacha Miner 9 • = REED ENGINEERING GROUP, LTD. Registration Number F -3114 Bill Woolwine Sr. Manager, CMT BW /cn 2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAx [214] 350 0019 Air Concrete Air Unit Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket No. ID inches Sample °F °F % Ibs /ft) Number 1 5072 4.0 3:55 PM 58 65 3.8 148.4 25622574 Note: (1) Concrete was sampled in accordance with ASTM C -31 (2) Concrete cylinders were tested in accordance with ASTM C -39 E -Mail Distribution: (1) Hillwood /Mr. Kerry Roetzel (1) Hillwood Construction Services/ Mr. Gary Jones (1) Halff Associates/ Mr. Stephen Crawford (1) Halff Associates /Mr. Lance Clinton (1) Macgregor Associates/ Mr. Thomas Holland (1) Macgregor Associates/ Mr. Lee Rader (1) City of Coppell /Mr. Lee Stone (1) City of Coppell /Mr. Michael Arellano (1) City of Coppell /Mr. Rick O'Dell (1) Ms. Sacha Miner 9 • = REED ENGINEERING GROUP, LTD. Registration Number F -3114 Bill Woolwine Sr. Manager, CMT BW /cn 2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAx [214] 350 0019