Loading...
CF-Deforest SC-CS 980910 PlanSolutions architects 100 Decker Ct, Suite 168, Irving, TX 75062 (972) 650-2077 Fax (972) 717-0037 E-Mail- architex~qash, net September 8, 1998 Sheri Moino ~w" City of Coppell ~ 'rain Offices Dear Shed: Enclosed please find the comments from the Texas Department of Licensing and Regulation regarding the project. Most of the comments are typical, although some of the items need attention. It is fairly serf expanatory. Please call if there are any questions. Sincerely, Bob Anderson TEXAS DEPA._,MENT OF LICENSING AN m 'REGULATION Code Review and ~spections ARCHITECTURAL BARRIERS P.O. Box 12157 Austin, Texas 78711 ~1~463-$211 FAX ~1~475-2886 BOB ANDERSON SEP-02-1998 PLAN SOLUTIONS ARCHITECTS BOB ANDERSON 100 DECKER CT STE 168 IRVING, TX 75062 Re: NORTH SERVICE CENTER EABPRJ98007710 ADMINISTRATION OFFICES 732 DEFOREST RD COPPELL, TX 75019 PLANS DATED MAY 5, 1998 PLAN CONDITIONAL APPROVAL Dear MR. ANDERSON Enclosed are the results of the plan review completed on the referenced project. Identified on the worksheet(s) are areas of nonconformance with accessibility standards adopted by the Texas Department of Licensing and Regulation for purposes of ensuring compliance with Article 9102, Texas Civil Statutes. Although nonconforming items have been noted, the referenced project will be eligible for approval if constructed according to the documents reviewed and as noted on the worksheet(s). Items which are the responsibility of the owner should be referred to the appropriate person for action. This determination does not address applicability of the Americans with Disabilities Act (ADA), (P. L. 101-336), or any other state, local, or federal requirement. For information on the ADA, call the ADA Hotline, (800)949-4232 or the United States Department of Justice at (202)514-0301. An inspection will be conducted- within one year of the completion date. The building owner will be contacted to arrange the inspection. Please reference the EABPRJ number in all future correspondence pertaining to this project. Austin Headquarters: E.O. Thompson State Office Building · 920 Colorado · Austin, Texas 78701 TEXAS DEPARTMENT OF LICENSING AND REGULATION PLANS AND SPECIFICATIONS REVIEW WORKSHEET PROJECT NO.: EABPRJ98007710 Article 9102, T.C.S. REVIEW : EAB1998023262R PAGE: 1 PROJECT: ADMINISTRATION OFFICES FACILITY: NORTH SERVICE CENTER OWNER: CITY OF COPPELLL ARCHITECT: PLAN SOLUTIONS ARCHITECTS REVIEWER: OLIVARES, GARY L. DATE: 08/29/98 4 ACCESSIBLE ELEMENTS AND SPACES: TECHNICAL REQUIREMENTS **APPLICATION: 4.1.2 ACCESSIBLE SITE ELEMENTS: NEW SITE **APPLICATION: 4.1.3 ACCESSIBLE BUILDINGS: NEW CONSTRUCTION **PROJECT DESCRIPTION: T~E SCOPE OF TEIS PROJECT CONSIST OF A NEW 5,771 SF ADMINISTRATION BUILDING. T~IS WILL INCLUDE NEW PARKING, CURB RAMP, OFFICES, CONFERENCE ROOM, STAFF SUPPORT ROOMS, COPY/MAIL ROOM AND RESTROOMS. FULL COMPLIANCE IS REQUIRED AT ALL AREAS.**** **COMMENT: "ENSURE" ACTION AS NOTED IN SECTION(S) DOES NOT WARRANT A WRITTEN RESPONSE; ONLY SECTION(S) NOTED "PLEASE RESPOND"~ WILL REQUIRE A WRITTEN RESPONSE TO ENSURE FULL COMPLIANCE WITH THE STANDARDS.** ACCEPTABLE 4.3 ACCESSIBLE ROUTE NOT NOTED 4.4 PROTRUDING OBJECTS ACCEPTABLE 4.5 GROUND AND FLOOR SURFACES UNACCEPTABLE 4.6 PARKING AND PASSENGER LOADING ZONES 4.6.1 Minimum Number **NOTE: SITE PLAN NOTES FOR 20 PARKING SPACES WITH 2 ACCESSIBLE PARKING SPACES; APPROVED.*** 4.6.3 Parking Spaces **NOTE: ENSURE T~AT THE WIDTH OF THE ACCESS AISLE IS 96" WIDE.** 4.6.4 Signage ~LANS ~ND SPECIFICATIONS RE~'"%W WORKSHEET '~ PROJECT NO.: EABPRJ98007710 Article 9102, T.C.S. REVIEW : EAB1998023262R PAGE: 2 PROJECT: ADMINISTRATION OFFICES FACILITY: NORTH SERVICE CENTER REVIEWER: OLIVARES, G;LRY L. DATE: 08/29/98 (1) Height **NOTE: ENSURE THAT VAN SIGNAGE IS PROVIDED AND THAT THE MOUNTING HEIGHT OF THE SIGNAGE COMPLIES WITH THIS SECTION.** UNACCEPTABLE 4.7 CURB RAMPS **NOTE: NO DETAILS PROVIDED TO VERIFY COMPLIANCE. ENSLTRE THAT THE SLOPE OF THE RAMP IS 1:12. THE TEXTURE AND THE COLOR CONTRAST SHALL COMPLY WITH ALL THE APPLICABLE REQUIREMENTS OF THIS SECTION.** NOT NOTED 4.8 RAMPS NOT NOTED 4.9 STAIRS NOT NOTED 4.10 ELEVATORS NOT NOTED 4.11 PLATFORM LIFTS (Wheelchair Lifts) NOT NOTED 4.12 WINDOWS UNACCEPTABLE 4.13 DOORS 4.13.5 Clear Width **NOTE: THE DOOR SCHEDULE AS NOTED IS ACCEPTABLE.** 4.13.6 Maneuvering Clearances at Doors **NOTE: THE MANEUVERING CLEARANCE AT EACH OF THE DOORS ARE APPROVED.** 4.13.8 Thresholds at Doorways **NOTE: ENSURE THAT THE HEIGHT OF THE THRESHOLD SHALL COMPLY WITH THIS SECTION.** 4.13.9 Door Hardware **NOTE: ENSURE THAT THE TYPE AND THE MOUNTING HEIGHT OF THE DOOR HARDWARE SHALL COMPLY WITH THIS SECTION.** ACCEPTABLE 4.14 ENTRANCES UNACCEPTABLE 4.15 DRINKING FOUNTAINS AND WATER COOLERS 4.15.1 General P~ANS A~D SPECIFICATIONS REV~~w WORKSHEET ~PROJECT NO.: EABPRJ98007710 Article 9102, T.C.S. REVIEW : EAB1998023262R PAGE: 3 PROJECT: ADMINISTRATION OFFICES FACILITY: NORTH SERVICE CENTER REVIEWER: OLIVARES, GARY L. DATE: 08/29/98 **NOTE: IF ONLY ONE DRINKING FOUNTAIN IS PROVIDED, ENSURE THAT THE UNIT IS ACCESSIBLE TO THOSE IN A WHEELCHAIR AND TO THOSE WHO HAVE DIFFCULTY BENDING OR STOOPING. THIS WILL REQUIRE A HI-LO UNIT. ENSURE THAT THE UNIT IN THIS PROJECT COMPLIES WITH THE REQUIREMENTS IN SECTION 4.1.3(10) AND THIS SECTION.** 4.15.2 Spout Height **NOTE: ENSURE THAT THE HEIGHT OF THE H.C. SPOUT IS 36" AFF.** 4.15.4 Controls **NOTE: ENSURE THAT THE LOCATION OF THE CONTROLS SHALL COMPLY WITH THIS SECTION.** 4.15.5 Clearances (1) Wall and Post-Mounted Units **NOTE: ENSURE THAT THE HEIGHT OF THE KNEE CLEARANCE SHALL COMPLY WITH THIS SECTION.** UNACCEPTABLE 4.16 WATER CLOSETS 4.16.2 Clear Floor Space **NOTE: ENSURE THAT THE CENTER OF THE WATER CLOSET IS 18" OC. FROM THE SIDE WALL.** 4.16.3 Height **NOTE: ENSURE THAT THE HEIGHT OF THE ACCESSIBLE WATER CLOSET SEAT COMPLIES WITH THIS SECTION.** 4.16.4 Grab Bars **NOTE: ENSURE THAT THE LENGTH AND THE POSITIONING OF THE GRAB BARS SHALL COMPLY WITH THIS SECTION.** 4.16.5 Flush Controls **NOTE: ENSURE THAT THE LOCATION OF THE FLUSH CONTROLS SHALL COMPLY WITH THIS SECTION.** UNACCEPTABLE 4.17 TOILET STALLS 4.17.5 Doors ~LANS A~D SPECIFICATIONS RES~ WORKSHEET ~ PROJECT NO.: EABPRJ98007710 Article 9102, T.C.S. REVIEW : EAB1998023262R PAGE: 4 PROJECT: ADMINISTRATION OFFICES FACILITY: NORTH SERVICE CENTER REVIEWER: OLIVARES, GARY L. DATE: 08/29/98 **NOTE: ENSURE THAT THERE IS 18" CLEAR3%NCE ~N THE PULL SIDE OF THE TOILET STALL DOORS.** UNACCEPTABLE 4.18 URINALS 4.18.2 Height **NOTE: ELEVATIONS NOTE THE URINAL RIM TO BE MOUNTED AT 17" AFF, APPROVED.*** **NOTE: ENSURE THAT THE URINAL EXTENDS OUT AT LEAST 14" FROM THE THE BACK WALL.** 4.18.3 Clear Floor Space **NOTE: IF THE DEPTH OF THE URINAL SCREEN IS GREATER THAN 24", THEN THE WIDTH OF THE CLEAR FLOOR SPACE SHALL BE 36". ENSURE COMPLIANCE IF REQUIRED.** 4.18.4 Flush Controls **NOTE: ENSURE MOUNTING HEIGHT OF THE FLUSH CONTROLS SHALL COMPLY WITH THIS SECTION.** UNACCEPTABLE 4.19 LAVATORIES AND MIRRORS 4.19.2 Height and Clearances **NOTE: ELEVATIONS NOTE THE TOP OF THE LAVATORY TO BE MOUNTED AT 34" AFF, ~_PPROVED. HOWEVER, ENSURE THAT THE HEIGHT OF THE KNEE CLEARANCE COMPLIES WITH THIS SECTION.** 4.19.4 Exposed Pipes and Surfaces Hot water and drain pipes under lavatories shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories. **NOTE: ENSURE COMPLIANCE WITH THIS SECTION.** 4.19.6 Mirrors **NOTE: ENSURE THAT THE MOUNTING HEIGHT OF THE MIRROR COMPLIES WITH THIS SECTION.** NOT NOTED 4.20 BATHTUBS NOT NOTED 4.21 SHOWER STALLS ACCEPTABLE 4.22 TOILET ROOMS P~ANS A~D SPECIFICATIONS REVF~ WORKSHEET ~PROJECT NO.: EABPRJ98007710 Article 9102, T.C.S. REVIEW : EAB1998023262R PAGE: 5 PROJECT: ADMINISTRATION OFFICES FACILITY: NORTH SERVICE CENTER REVIEWER: OLIVARES, GARY L. DATE: 08/29/98 4.22.1 Minimum Number **NOTE: ONE MEN GANG AND ONE WOMEN GANG TOILET ROOM PROVIDED.** NOT NOTED 4.23 BATHROOMS, BATHING FACILITIES, AND SHOWER ROOMS UNACCEPTABLE 4.24 SINKS 4.24.2 Height **NOTE: T~E ELEVATIONS NOTE T~E HEIGHT OF THE SINK TO BE 34" AFF, APPROVED. HOWEVER, ENSURE T~AT THE HEIGHT OF THE KNEE CLEARANCE COMPLIES WIT~ THIS SECTION.** 4.24.4 Depth **NOTE: ENSURE T~{AT T~E DEPT~ OF T~E SINK COMPLIES WIT~ THIS SECTION.** 4.24.6 Exposed Pipes and Surfaces Hot water and drain pipes exposed under sinks shall be insulated or otherwise configured so as to protect against contact. There shall be no sharp or abrasive surfaces under sinks. **NOTE: ENSURE COMPLIANCE WIT}{ T~IS SECTION.** UNACCEPTABLE 4.25 STORAGE 4.25.3 Height Accessible storage spaces shall be within at least one of the reach ranges specified in 4.2.5 and 4.2.6 (see Fig. 5 and Fig. 6). Clothes rods or shelves shall be a maximum of 54 in (1370 mm) above the finish floor for a side approach. Where the distance from the wheelchair to the clothes rod or shelf exceeds 10 in (255 mm) (as in closets without accessible doors) the height and depth to the rod or shelf shall comply with Fig. 38(a) and Fig. 38(b). **NOTE: ENSURE COMPLIANCE WITH THIS SECTION.** UNACCEPTABLE 4.26 F~NDRAILS, GRAB BARS, AND TUB AND SHOWER SEATS 4.26.3 Structural Strength **NOTE:ENSURE THAT BLOCKING IS PROVIDED INSIDE THE WALLS TO SUPPORT THE GR3%B BARS.** UNACCEPTABLE 4.27 CONTROLS AND OPERATING MECHANISMS 4.27.3 Height P~ANS A~D SPECIFICATIONS REV~ WORKSHEET ~ PROJECT NO.: EABPRJ98007710 Article 9102, T.C.S. REVIEW : EAB1998023262R PAGE: 6 PROJECT: ADMINISTRATION OFFICES FACILITY: NORTH SERVICE CENTER REVIEWER: OLIVD~RES, GARY L. DATE: 08/29/98 **NOTE: ENSURE THAT THE HEIGHT OF THE ELECTRICAL DEVICES (LIGHT SWITCHES AND OUTLETS) COMPLY WITH THIS SECTION.** NOT NOTED 4.28 AIJ~RMS 4.28.1 General **NOTE: IF ALARMS ARE TO BE PROVIDED, ENSURE COMPLIANCE WITH THIS SECTION.*** NOT NOTED 4.29 DETECTABLE WARNINGS NOT NOTED 4.30 SIGNAGE **NOTE: IF SIGNAGE IS TO BE PROVIDED, ENSURE COMPLIANCE WITH THIS SECTION.** NOT NOTED 4.31 TELEPHONES UNACCEPTABLE 4.32 FIXED OR BUILT-IN SEATING AND TABLES 4.32.4 Height of Tables or Counters **NOTE: ENSURE T~AT A 36" LONG PORITION OF THE CONFERENCE ROOM COUNTER IS MOUNTED AT 34" AFF.** NOT NOTED 4.33 ASSEMBLY AREAS NOT NOTED 4.34 AUTOMATED TELLER MACHINES NOT NOTED 4.35 DRESSING AND FITTING ROOMS NOT NOTED 5 RESTAURANTS, CAFETERIAS, SNACK BARS, AND VENDING AREAS 5.1 GENERAL 5.2 COUNTERS AND BARS 5.3 ACCESS AISLES 5.4 DINING AREAS 5.5 FOOD SERVICE LINES 5.6 TABLEWARE AND CONDIMENT AREAS 5.7 RAISED PLATFORMS 5.8 VENDING MACHINES AND OTHER EQUIPMENT P~ANS A~ SPECIFICATIONS REV~ WORKSHEET '~PROJECT NO.: EABPRJ98007710 Article 9102, T.C.S. REVIEW : EAB1998023262R PAGE: 7 PROJECT: ADMINISTRATION OFFICES FACILITY: NORTH SERVICE CENTER REVIEWER: OLIVARES, GARY L. DATE: 08/29/98 5.9 QUIET AREAS (Reserved) NOT NOTED 6 MEDICAL CARE FACILITIES 6.1 GENERAL 6.2 ENTRANCES 6.3 PATIENT BEDROOMS 6.4 PATIENT TOILET ROOMS 6.5 SIZE OF AREAS OF RESCUE ASSISTANCE 6.6 INFORMATION COUNTERS AND NURSES STATIONS NOT NOTED 7 BUSINESS AND MERCANTILE 7.1 GENERAL 7.2 SALES AND SERVICE COUNTERS, TELLER WINDOWS, INFORMATION COUNTERS 7.3 CHECK-OUT AISLES 7.4 SECURITY BOLLARDS AND TURNSTILES NOT NOTED 8 LIBRARIES 8.1 GENERAL 8.2 READING AND S~3DY AREAS 8.3 CHECK-OUT AREAS 8.4 CARD CATALOGS AND MAGAZINE DISPLAYS 8.5 STACKS NOT NOTED 9 ACCESSIBLE TRANSIENT LODGING 9.1 HOTELS, MOTELS, INNS, BOARDING HOUSES, DORMITORIES, RESORTS, ETC 9.2 REQUIREMENTS FOR ACCESSIBLE UNITS, SLEEPING ROOMS AND SUITES 9.3 VISUAL ALARMS, NOTIFICATION DEVICES AND TELEPHONES 9.4 OTHER SLEEPING ROOMS AND SUITES 9.5 SHELTERS, HALFWAY HOUSES, GROUP HOMES, OTHER ESTABLISHMENTS. PLANS AND SPECIFICATIONS REF~W WORKSHEET ~"~ PROJECT NO.: EABPRJ98007710 Article 9102, T.C.S. REVIEW : EAB1998023262R PAGE: 8 PROJECT: ADMINISTRATION OFFICES FACILITY: NORTH SERVICE CENTER REVIEWER: OLIVARES, GARY L. DATE: 08/29/98 NOT NOTED 10 TRANSPORTATION FACILITIES 10.1 GENERAL 10.2 BUS STOPS AND TERMINALS 10.3 FIXED FACILITIES AND STATIONS 10.4 AIRPORTS 10.5 BOAT AND FERRY DOCKS (Reserved)