Neighborhood CU-LR130418
Concrete Cylinders Strength Report
ECS Texas, LLP
4950 Keller Springs Road, Suite 480
Addison, TX 75001
Project :Set Designation:A
5924-B
(972) 392-3222 [Phone]
Cast Date:
(972) 392-0102 [FAx]
03/21/2013
Design Strength:
3600 psi
Project:Neighborhood Credit Union
Report No.:
4
Location:360 S. Denton Tap Road, Coppell, TX
LEVEL5, LLC - J.R. Aguero
Owner:Client:
Arch.:
Gen. Contr.:LEVEL5, LLC - J.R. Aguero
Struc. Eng.:Conc. Contr.:
Placement Location:Paving
Concrete Supplier:Cow Town Redi-MixTruck No:940Ticket No:566470
Mix Designation:260-2Mix Strength:3600 psiBatch Time:
06:38AM
Added Water:
Time Added:Unit Wt.:
Brandon New5.00 in.
FIELD TEST DATA:Tested by:Time Sampled:07:41AMSlump:
Air Content:
Temperature - Air:52º FConcrete:63º F
3.80 % (P)
TypeArea
SampleTestTestBreakingBrkReview
Diameter
Compr.
CureIn.In.²
NoDateAgeTypby
Load,lbsStr.,psi
03/28/2013
839657Lab4.0012.565187241303DME
04/18/2013
8396628Lab4.0012.567017655802DME
04/18/2013
8396728Lab4.0012.566748853703DME
04/18/2013
8396828Lab4.0012.566460851403DME
05/16/2013
8396956Lab
Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard.
Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P),
temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617.
Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39.
FIELD CURING CONDITIONS:
InsulatedCooledIce
Curing Box
X
No Curing BoxHeatedCapsOther
Remarks:
Final Review By:
DME
Print Date:04/19/2013
BR01
Concrete Cylinders Strength Report
ECS Texas, LLP
4950 Keller Springs Road, Suite 480
Addison, TX 75001
Project :Set Designation:B
5924-B
(972) 392-3222 [Phone]
Cast Date:
(972) 392-0102 [FAx]
03/21/2013
Design Strength:
3600 psi
Project:Neighborhood Credit Union
Report No.:
5
Location:360 S. Denton Tap Road, Coppell, TX
LEVEL5, LLC - J.R. Aguero
Owner:Client:
Arch.:
Gen. Contr.:LEVEL5, LLC - J.R. Aguero
Struc. Eng.:Conc. Contr.:
Placement Location:Paving
Concrete Supplier:Cow Town Redi-MixTruck No:919Ticket No:566483
Mix Designation:260-2Mix Strength:3600 psiBatch Time:
08:29AM
Added Water:
Time Added:Unit Wt.:
Brandon New5.25 in.
FIELD TEST DATA:Tested by:Time Sampled:09:35AMSlump:
Air Content:
Temperature - Air:52º FConcrete:67º F
4.00 % (P)
TypeArea
SampleTestTestBreakingBrkReview
Diameter
Compr.
CureIn.In.²
NoDateAgeTypby
Load,lbsStr.,psi
03/28/2013
839707Lab4.0012.564634436905DME
04/18/2013
8397128Lab4.0012.565560044203DME
04/18/2013
8397228Lab4.0012.565452943403DME
04/18/2013
8397328Lab4.0012.566076848402DME
05/16/2013
8397456Lab
Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard.
Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P),
temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617.
Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39.
FIELD CURING CONDITIONS:
InsulatedCooledIce
Curing Box
X
No Curing BoxHeatedCapsOther
Remarks:
Final Review By:
DME
Print Date:04/19/2013
BR01
Concrete Cylinders Strength Report
ECS Texas, LLP
4950 Keller Springs Road, Suite 480
Addison, TX 75001
Project :Set Designation:C
5924-B
(972) 392-3222 [Phone]
Cast Date:
(972) 392-0102 [FAx]
03/21/2013
Design Strength:
3600 psi
Project:Neighborhood Credit Union
Report No.:
6
Location:360 S. Denton Tap Road, Coppell, TX
LEVEL5, LLC - J.R. Aguero
Owner:Client:
Arch.:
Gen. Contr.:LEVEL5, LLC - J.R. Aguero
Struc. Eng.:Conc. Contr.:
Placement Location:Paving
Concrete Supplier:Cow Town Redi-MixTruck No:933Ticket No:566490
Mix Designation:260-2Mix Strength:3600 psiBatch Time:
09:17AM
Added Water:
Time Added:Unit Wt.:
Brandon New5.00 in.
FIELD TEST DATA:Tested by:Time Sampled:10:05AMSlump:
Air Content:
Temperature - Air:52º FConcrete:65º F
3.90 % (P)
TypeArea
SampleTestTestBreakingBrkReview
Diameter
Compr.
CureIn.In.²
NoDateAgeTypby
Load,lbsStr.,psi
03/28/2013
839757Lab4.0012.564640036904DME
04/18/2013
8397628Lab4.0012.565874046705DME
04/18/2013
8397728Lab4.0012.565897646902DME
04/18/2013
8397828Lab4.0012.566419251103DME
05/16/2013
8397956Lab
Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard.
Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P),
temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617.
Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39.
FIELD CURING CONDITIONS:
InsulatedCooledIce
Curing Box
X
No Curing BoxHeatedCapsOther
Remarks:
Final Review By:
DME
Print Date:04/19/2013
BR01
Concrete Cylinders Strength Report
ECS Texas, LLP
4950 Keller Springs Road, Suite 480
Addison, TX 75001
Project :Set Designation:D
5924-B
(972) 392-3222 [Phone]
Cast Date:
(972) 392-0102 [FAx]
03/21/2013
Design Strength:
3600 psi
Project:Neighborhood Credit Union
Report No.:
7
Location:360 S. Denton Tap Road, Coppell, TX
LEVEL5, LLC - J.R. Aguero
Owner:Client:
Arch.:
Gen. Contr.:LEVEL5, LLC - J.R. Aguero
Struc. Eng.:Conc. Contr.:
Placement Location:Paving
Concrete Supplier:Cow Town Redi-MixTruck No:948Ticket No:566503
Mix Designation:260-2Mix Strength:3600 psiBatch Time:
10:33AM
Added Water:
5 Gals.Time Added:Unit Wt.:
Brandon New5.25 in.
FIELD TEST DATA:Tested by:Time Sampled:11:17AMSlump:
Air Content:
Temperature - Air:52º FConcrete:72º F
4.20 % (P)
TypeArea
SampleTestTestBreakingBrkReview
Diameter
Compr.
CureIn.In.²
NoDateAgeTypby
Load,lbsStr.,psi
03/28/2013
839807Lab4.0012.564969639504DME
04/18/2013
8398128Lab4.0012.566115248702DME
04/18/2013
8398228Lab4.0012.566460851403DME
04/18/2013
8398328Lab4.0012.566204849403DME
05/16/2013
8398456Lab
Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard.
Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P),
temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617.
Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39.
FIELD CURING CONDITIONS:
InsulatedCooledIce
Curing Box
X
No Curing BoxHeatedCapsOther
Remarks:
Final Review By:
DME
Print Date:04/19/2013
BR01
Concrete Cylinders Strength Report
ECS Texas, LLP
4950 Keller Springs Road, Suite 480
Addison, TX 75001
Project :Set Designation:E
5924-B
(972) 392-3222 [Phone]
Cast Date:
(972) 392-0102 [FAx]
03/21/2013
Design Strength:
3600 psi
Project:Neighborhood Credit Union
Report No.:
8
Location:360 S. Denton Tap Road, Coppell, TX
LEVEL5, LLC - J.R. Aguero
Owner:Client:
Arch.:
Gen. Contr.:LEVEL5, LLC - J.R. Aguero
Struc. Eng.:Conc. Contr.:
Placement Location:Paving
Concrete Supplier:Cow Town Redi-MixTruck No:934Ticket No:566513
Mix Designation:260-2Mix Strength:3600 psiBatch Time:
11:39AM
Added Water:
5 Gals.Time Added:Unit Wt.:
Brandon New5.00 in.
FIELD TEST DATA:Tested by:Time Sampled:12:30PMSlump:
Air Content:
Temperature - Air:52º FConcrete:72º F
4.00 % (P)
TypeArea
SampleTestTestBreakingBrkReview
Diameter
Compr.
CureIn.In.²
NoDateAgeTypby
Load,lbsStr.,psi
03/28/2013
839857Lab4.0012.565196841405DME
04/18/2013
8398628Lab4.0012.56639045090DME
04/18/2013
8398728Lab4.0012.566384050803DME
04/18/2013
8398828Lab4.0012.566368050703DME
05/16/2013
8398956Lab
Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard.
Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P),
temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617.
Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39.
FIELD CURING CONDITIONS:
InsulatedCooledIce
Curing Box
X
No Curing BoxHeatedCapsOther
Remarks:
Final Review By:
DME
Print Date:04/19/2013
BR01
Concrete Cylinders Strength Report
ECS Texas, LLP
4950 Keller Springs Road, Suite 480
Addison, TX 75001
Project :Set Designation:F
5924-B
(972) 392-3222 [Phone]
Cast Date:
(972) 392-0102 [FAx]
03/21/2013
Design Strength:
3600 psi
Project:Neighborhood Credit Union
Report No.:
9
Location:360 S. Denton Tap Road, Coppell, TX
LEVEL5, LLC - J.R. Aguero
Owner:Client:
Arch.:
Gen. Contr.:LEVEL5, LLC - J.R. Aguero
Struc. Eng.:Conc. Contr.:
Placement Location:Paving
Concrete Supplier:Cow Town Redi-MixTruck No:940Ticket No:566529
Mix Designation:260-2Mix Strength:3600 psiBatch Time:
01:12PM
Added Water:
10 Gals.Time Added:Unit Wt.:
Brandon New4.75 in.
FIELD TEST DATA:Tested by:Time Sampled:02:54PMSlump:
Air Content:
Temperature - Air:52º FConcrete:72º F
3.20 % (P)
TypeArea
SampleTestTestBreakingBrkReview
Diameter
Compr.
CureIn.In.²
NoDateAgeTypby
Load,lbsStr.,psi
03/28/2013
839907Lab4.0012.564169633203DME
04/18/2013
8399128Lab4.0012.565651245001DME
04/18/2013
8399228Lab4.0012.565446443303DME
04/18/2013
8399328Lab4.0012.565603244602DME
05/16/2013
8399456Lab
Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard.
Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P),
temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617.
Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39.
FIELD CURING CONDITIONS:
InsulatedCooledIce
Curing Box
X
No Curing BoxHeatedCapsOther
Remarks:
Final Review By:
DME
Print Date:04/19/2013
BR01
Concrete Cylinders Strength Report
ECS Texas, LLP
4950 Keller Springs Road, Suite 480
Addison, TX 75001
Project :Set Designation:G
5924-B
(972) 392-3222 [Phone]
Cast Date:
(972) 392-0102 [FAx]
03/21/2013
Design Strength:
3600 psi
Project:Neighborhood Credit Union
Report No.:
10
Location:360 S. Denton Tap Road, Coppell, TX
LEVEL5, LLC - J.R. Aguero
Owner:Client:
Arch.:
Gen. Contr.:LEVEL5, LLC - J.R. Aguero
Struc. Eng.:Conc. Contr.:
Placement Location:Paving
Concrete Supplier:Cow Town Redi-MixTruck No:927Ticket No:566551
Mix Designation:260-2Mix Strength:3600 psiBatch Time:
04:05PM
Added Water:
Time Added:Unit Wt.:
Brandon New4.25 in.
FIELD TEST DATA:Tested by:Time Sampled:04:40PMSlump:
Air Content:
Temperature - Air:52º FConcrete:75º F
3.50 % (P)
TypeArea
SampleTestTestBreakingBrkReview
Diameter
Compr.
CureIn.In.²
NoDateAgeTypby
Load,lbsStr.,psi
03/28/2013
839957Lab4.0012.565900847003DME
04/18/2013
8399628Lab4.0012.567411259002DME
04/18/2013
8399728Lab4.0012.566643252903DME
04/18/2013
8399828Lab4.0012.567683261102DME
05/16/2013
8399956Lab
Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard.
Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P),
temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617.
Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39.
FIELD CURING CONDITIONS:
InsulatedCooledIce
Curing Box
X
No Curing BoxHeatedCapsOther
Remarks:
Final Review By:
DME
Print Date:04/19/2013
BR01