Loading...
Neighborhood CU-LR130419 Concrete Cylinders Strength Report ECS Texas, LLP 4950 Keller Springs Road, Suite 480 Addison, TX 75001 Project :Set Designation:A 5924-B (972) 392-3222 [Phone] Cast Date: (972) 392-0102 [FAx] 04/12/2013 Design Strength: 4000 psi Project:Neighborhood Credit Union Report No.: 12 Location:360 S. Denton Tap Road, Coppell, TX LEVEL5, LLC - J.R. Aguero Owner:Client: Arch.: Gen. Contr.:LEVEL5, LLC - J.R. Aguero Struc. Eng.:Conc. Contr.: Placement Location:Screen Wall Footing Concrete Supplier:Cow Town Redi-MixTruck No:938Ticket No:567474 Mix Designation:260-2Mix Strength:4000 psiBatch Time: 10:15AM Added Water: Time Added:Unit Wt.: RJ Fullmer6.00 in. FIELD TEST DATA:Tested by:Time Sampled:11:20AMSlump: Air Content: Temperature - Air:71º FConcrete:64º F 5.00 % (P) TypeArea SampleTestTestBreakingBrkReview Diameter Compr. CureIn.In.² NoDateAgeTypby Load,lbsStr.,psi 04/19/2013 843117Lab4.0012.564220833603DME 05/10/2013 8431228Lab 05/10/2013 8431328Lab 05/10/2013 8431428Lab 06/07/2013 8431556Lab Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. FIELD CURING CONDITIONS: InsulatedCooledIce Curing Box X No Curing BoxHeatedCapsOther Remarks: Final Review By: DME Print Date:04/22/2013 BR01