Loading...
CF-Village-CS 881020 (2) Suite ~00, LB-~18 DALLAS, TE~S 752~ ~'~' 10-20-887~/~1~F :o..o... 380 (214) 2~900 ~.~,o. ~~~1~,~. ~. TO C~7 of Coppe[[ ~.0. Sox ~78 iv/ ~/ t WE ARE SENDING YOU ~Affach~ ~ Under s~ 2'~~. the following items: ~ Shop drawings ~ Prints ~ Plans ~ ~ples ~ S~ifications ~ Copy of le~er ~ Change o~er COPI ES DATE NO. DESCRIPTION ]. 10-20-88 Addendum #2 ~/~T THESE ARE TRANSMITTED as checked below: [] For approval [] Approved as submitted [] Resubmit copies for approval Z~ For your use [] Approved as noted [] Submit copies for distribution [] As requested [] Returned for corrections [] Return corrected prints [] For review and comment I~ [] FOR BIDS DUE 19 [] PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO SIGNED: o~ootJC~2~.~ /: ~,v~-~/iec. ~ ~ ~:~:~ If enclosures ere not es noted, kindty notify us et ADDENDUM NO. 2 PROJECT: VILLAGE PARKWAY PUMP STATION (RFP 0030) OWNER: City of Coppell, Texas BID OPENING: 10:00 A.M., Thursday, October 27, 1988, at Coppell Town Center, 255 Parkway Blvd., Coppell, Texas. ISSUED BY: Ginn, Inc. Consulting Engineers for the City of Coppell, Texas THE PROPOSED CONTRACT DRAWINGS AND/OR SPECIFICATIONS FOR THE ABOVE REFERENCED PROJECT ARE FURTHER MODIFIED AS FOLLOWS: DRAWING C-Z; SITE PLAN: Sheet 4 of 46, re-issued 1. Location of Proposed (under this contract) and Existing (by others) fence revised. Relocation of temporary fence deleted. 2. Tank diameter revised to 152'. DRAWING C-3: ENLARGED SITE PLAN & DETAILS: Sheet 5 of 46, re-issued 1. Clarified location of proposed concrete lined channel under this contract. 2. Location of Proposed (under this contract) and Existing (by others) fence revised. Relocation of temporary fence deleted. DRAWING C-$~ YARD PIPING PL]tN AND DETAILS: Sheet 7 ~f 46, re-issued 1. Clarified location of proposed concrete lined channel under this contract. 2. Revised pipe connections as noted. 3. Location of Proposed (under this contract) and Existing (by others) fence revised. Relocation of temporary fence deleted. GINN, INC. CONSULTING ENGINEERS VILLAGE PARKWAY PUMP STATION DALLAS, TEXAS PROJECT NO. 380 CITY O~ COPPELL, TEXAS . ~, ~I/)DELVDUE ~0. 2 · PAGE 2 DRAWING C-7; PIPING FLOOR PLAN & DETAILS: Sheet 9 of 46 1. Add one 1/2 inch pressure tap (ref. Drawing I-3, Detail 5) to each suction and discharge pipe (6 taps total; supply 2 gage assemblies and 4 plugs). Exact location to be specified by Engineer at time of shop drawing submittal. NOTE: THIS DRAWING NOT RE-ISSUED. DRAWING 8-2; STRUCTURAL FOUNDATION PLAN: Sheet 18 of 46, re-issued 1. Removed equipment pads. Added steel channels for equipment. DRAWING I-3; INSTRUMENTATION DETAILS: Sheet 26 of 46, re-issued 1. Added detail #2, other changes as noted. DRAWING E-l= SITE PLAN= Sheet 27 of 46, re-issued 1. The primary service conduits have been revised, as well as miscellaneous sections and notes. DRAWING E-5~ PLaN VIEW POWER ~ND CONTROL: Sheet 31 of 46 Add the following notes to the POWER AND CONTROL PLAN VIEW: 1. Flush mounted disconnects shall be NEMA i Square D, #FA100F with 30 amp 2 pole type FA breaker. 2. Install a # 6 solid ground wire from the telephone cabinet to hot water heater cold water pipe. Install in conduit and bond to conduit at each end. 3. Install a duplex receptacle inside telephone cabinet. Install a home run to lighting panel in low voltage · motor control center. 4. All conduit run under slab shall be as specified under Section 16410 - Underground. Ail conduit run in slab shall be Schedule 40 PVC with galvanized rigid steel bends. 5. Ail conduits entering motor control centers and instrument panel from the bottom shall be sealed with Dux-seal after all cables have been installed. Cap empty and spare conduits with threaded end caps. NOTE: THIS DRAWING NOT RE-ISSUED. GINN, INC. CONSULTING ENGINEERS VILLAGE PARKWAY PUMP STATION DALLAS, TEXAS PROJECT NO. 380 CITY OF COPPELL, TEXAS ~ ~DDEND~M NO. 2 PAGE 3 DRAWING E-?; SECTIONS AND DETAILS: Sheet 33 of 46 Add the following note to Detail # 3: 1. PVC pipe and couplings embedded in concrete will be installed under the Ground Storage Tank Contract (by others). Add the following note to Detail # 5: 2. Ail receptacles shall be GFCI/WP. Add the following note to Detail # 6: 3. Number and size of conduits shall be as shown on the plans. NOTE: THIS DRAWING NOT RE-ISSUED. SECTION 02444 - CHAIN LINK FENCE AND GATES Add Paragraph 2.6: POLYVINYL COATING 2.6 POLYVINYL COATING Ail polyvinyl coatings specified in this section shall be a bonded type with a minimum thickness of 7 mils. Color to be selected by the Owner. SECTION 13500 - COMMUNICATIONS Paragraph 3.02, Add the following: 3.02 Furnish to Owner, the following spare parts: A. One (1) spare analog tone transmitter. B. One (1) spare analog tone receiver. SECTION 13610 - MAIN CONTROL PANEL Paragraph 3.031 Add the following: 3.03 Furnish to the Owner, the following spare parts: A. One (1) spare level controller. B. Three (3) spare control relays and matching sockets. GINN, INC. CONSULTING ENGINEERS VILLAGE PARKWAY PUMP STATION DALLAS, TEXAS PROJECT NO. 380 CITY OF COPPELL, TEXAS ADD~NDU~ NO. 2 SECTION 15500 - H~AC Paragraph 2.06; Add the following: C. Attic exhaust fans shall be Penn model Z-14. Ductwork shall be as specified under part 2.02 of this section. ISSUED THIS 20th DAY OF OCTOBER, 1988. GINN, INC. CONSULTING ENGINEERS Sanford W. Case, P.E. Project Manager BIDDER'S ARE REMINDED OF THE FOLLOWING: 1. Receipt of this Addendum must be acknowledged on the executed Proposal and Bid Forms. 2. All Proposals must bo submitted in duplicate (same envelope is acceptable). GINN, INC. CONSULTING ENGINEERS VILLAGE PARKWAY PUMP STATION DALLAS, TEXAS PROJECT NO. 380 CITY OF COPPELL, TEXAS