Loading...
CF-Andrew Park 1-PR 940715 TEL: Jul 19 9~ · ./,~, PO'FI,R CO C ET CO., ..... Concrete Contractor~ ' 10:57 No.O0? P.02 July 15, 1994 Larry Davis The £ollowing is our proposal for the concrete work at the above referenced project. We propose to furnish all'labor, materials and equipment necessary to complete the work outlined.below. co~g~yE PAyX~ 5" Paving Reinforced with #3 @ 24" O.C.E.W. 6" Flex Base Compacted to 95% Density. 160,000 sr. 160,000 sr. FOR THE Lb'J, IP mlmOF $ 5" Paving Reinforced with Fiber Mesh 6" Fi~ Base Compacted to 95% Density. 160,000 sr. 160,000 sf. FZlllI. MBIH 3:fl HOT RBCO)IIBMII~ BY ~l COICRrT]I~. 2" Hot Mix Type "D" with Prime Coa~. 6" Flex Base Compacted to 95% Density 160,000 160,000 sf. FOR THE LM fltUMOF 4820GretnaDallas, Texas 75207 Office 2'14-630-2~9'~ FAX 2{4-689-~066 TEL; Jul 19 9~ 10:58 No.O0? P.O$ #e acknowledge having received addendum No.'ss NONE. Our proposal is based upon the following assumptions and/or exclusions. And is subject to a mutual agreement on contract documents. 1. We exclude any and all demolition. 2. We assume the sub-grade to be plus or minus one-tenth by others. 3. ~We have included fine grading and fine grading sand. we include engineering and layout for the concrete work listed above. We assume the concrete to be 3000 PSI. We assume all concrete will allow a 5" slump. We exclude heating or cooling of concrete. We exclude all concrete buggies or pumps. We assume the concrete truck~ will be allowed to back over the rebar or seven-day-old concrete in order to pour. We assume wasting spoils and any other excavated materials on site. At the sitework, we have included expansion joints at 100'-0" on center and saw joints a% 20'-0" on center. We exclude all sealing or caulking of joints. We assume that redwood expansion joints with load transfer devices, similar to keylode, will be acceptable. We exclude dowel baskets. We have included curing the paving with a white-pigmented curing compound at 300 s.f. per gallon. We exclude backfilling at curbs and walks. We assume the landscaping contractor will perform this work. We assume 6" Flex Base is existing. We have included scarifing, water and recompaction only. we exclude materials and labor to install PVC sleeves. We assume the landscaper will perform this work. We exclude any ¢oncret~ cleaning, striping or painting. we have excluded all off sitework. We exclude all utility work; i.e. culverts, headwalls, manholes, curb inlets, etc. We exclude adjusting utilities; i.e. storm drains, area-drains, etc. Unles! stated in our Scope of Work, we exclude all bollards, pole bases, pre-cast wheel stops, miscellaneous pads, etc. 20. We have included all rebar and rebar tying for the concrete work listed above. We assume plastic chairs are acceptable. We ew£1ude all masonry rebar. 21. We:='lude all patching of asphalt. 22. We :lude barricades. TEL: Jul 19 9~ 10:SS No.O07 P.04 czt, qr et, OOaPULL 23. 24. 25. #e aesu~ this project will be classified as new construction. Ne hive included sales tax for the materiels and equipment rentals purchased for the concrete work listed ebove. We exclude ell permits, bonds or concrete testing. We exclude bid, performance or payment bonds. ~ I~reciate the opportunity to bid this project. If you have any questions plelse do not hesitate to call. If ~his proposal is i=u~ed, it becomes e part o£ the contract. Sincerely, 1 Nails Estimator m /gg TEL: Jul 19 94 10:5? No.O0? P.01 PO" ER CON(DI,~I::IP.. UL..~ INLJ, ~ Concrete Contractors FAX TRANSMITTAL DATE: '7'."~, ,~' ~¢ FROM : POTTER ~TE CO., INC. INDIVIDUAL: /"7,~L,Z 1""/~(,.,/...~ FAX NUMBER: (214) ~-1066 TO: COMPANY: NUMBER OF PAGES ~UDING THIS PAGE: FAX NUMBER: .~ ~'$.,.':.,_~ ~_~ IF THERE ARE ANY PIIIII)IBLEMS IN THE TRANSMISSION FAX PLEASE CALL OF THIS MESSAGE: · '.1820 Gretna Dalk],.;, l'exa,.; 7,5207 Offic.,~ 2'14-630-2.19.1 FAX 2t4-6~9-'1066