Loading...
CF-Andrew Park 2-LR 940608ALPHA TESTING, INC. 2209 WisconsIn St. Suite 100 Dallas. Texas 75229 (214) 620-8911 REPORT OF CONCRETE COMPRESSION TEST TESTEDFOR ROOH~ EXCAVATION, INC. FRISCO· TEXAS DATE: 06/08/94 PROJECT ANDREW BROWN 3R. COMMUNZTY PARK PHASE COPPELL, TEXAS II OUR REPORT NO. 94001-30 S I DEWALK LOCATION OF CONCRETE PLACEMENT E. LAKE · N. 06/08/94 DATE PLACED 10:05 TIME SLUMP 4 AIR CONTENT 84 AIR TEMPERATURE CONCRETE TEMPERATURE 87 06/09/94 DATE RECEIVED FIELD DATA SUBMITTED BY HPM MIX DATA SUBMITTED BY LATT FIE LD DATA SIDE TRAIL 6 PLANT 6003821 DELIVER TICKET NO. N/A MIX PROPORTIONS (SSD) CEMENT N/A WATER N/A FINE AGGREGATE N/A COARSE AGGREGATE N/A ADMIXTURE N/A COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6- X 12") Lab. Cuatomer Type Date ~ Comp~ee~ve No. No. Curing Treed Days Strength, Psi 53 94001 LAB 06/15/94 7 2100 54 I 94001 LAB 07/06/94 28 55 94001 LAB 07/06/94 28 56 94001 LAB HOLD Spec,t,ca,,ons 21~ ~UUL~ REMARKS [~Cylinders made by ALPHA representative. [] Cylinders made by Architect's or Contractor's representative. [~CCylinders picked up by ALPHA laboratory. [] Cylinders delivered to ALPHA laboratory. [] Compression test results comply with applicable specifications. [] Compression test results do not comply with applicable specifications. TYPE OF FRACTURE, IF OTHER AN CONILL R~/I~_ fqlly Submitted David P. Stettner ALPHA TESTING, INC.