CF-Andrew Park 2-LR 940602ALPHA TESTING, INC.
2209 Wisconsin St.
Suite 100
Dallas. Texas 75229
(214) 620-8911
REPORT OF CONCRETE
COMPRESSION TEST
TESTED FOR
ROOI~RN EXCAVAT]:ON, [NC.
FR]:SCO, TEXAS
DATE:
06/02/94
PROJECT
ANDREW BROWN 3R.
COI~IUNTTY PARK PHASE 1'1'
COPPELL, TEXAS
OUR REPORT NO.
94001-26
LOCATION OF CONCRETE PLACEMENT PIERS:
06/02/94
DATE PLACED
TIME 11: 20
4.25"
SLUMP
AIR CONTENT N/A
AIR TEMPERATURE 82
CONCRETE TEMPERATURE 89
DATE RECEIVED 06/03/94
FIELD DATA SUBMITTED BY
MIX DATA SUBMIT'TED BY LATT
FIELD DATA
#1-7
PLANT 7
DELIVER TICKET NO. 7001723
MIX PROPORTIONS (SSD) N/A
CEMENT N/A
WATER N/A
FINE AGGREGATE
COARSE AGGREGATE N/A
ADMIXTURE N/A
COMPRESSION TEST RESULTS
{NOMINAL CYLINDER SIZE S" X
Lab. Custom..r Type Dire ~ Comprem;v®
No. No. Curing Telt~l DIyI Strength, Pli
41 94001 LAB 06/09/94 7 42~0
42 I 94001 LAB 06/30/94 28 5210
43 94001 L~B 06/30/94 28 5340
44 ~ 94001 L~B H~D
,,~,,,~ 28 3000
REMARKS
[~'ylinders made by ALPHA
representative.
~ Cylinders made by Architect's
or Contractor's representative.
~linders picked up by ALPHA
laboratory.
[] Cylinders delivered to ALPHA
laboratory.
[~mpression test results comply with
applicable specifications.
[] Compres,~on lesl results do no~ comply
with applicable specifications.
:, IF OTHER