Loading...
CF-Andrew Park 2-LR 940602 (5)ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas. Texas 75229 (214) 620-8911 REPORT OF CONCRETE COMPRESSION TEST TESTED FOR ROI)Iq/~IEXCAVATIO~, INC. FRISCO, TEXAS DATE: 06/02/94 PROJECT ~d~IDRENBROI4N 3R. C~ITY PP~K PI-~SE II COPPELL, TEXAS OUR REPORT NO. 94001-27 FIE LO DATA LOCATION OF CONCRETE PLACEMENT PAVEHENT E. SIDE OF 14. LAKE IO0'N FROH SE CORNER OF LR~(E DATE PLACED 06,/02/94 PLANT 7 TIME 11; 50 DELIVER TICKET NO. 7001727 SLUMP 2.5" MIX PROPORTIONS (SSD) N/A AIR CONTENT 4 CEMENT N/A AIR TEMPERATURE 83 WATER N/A CONCRETE TEMPERATURE 87 FINE AGGREGATE N/A DATE RECEIVED 06/03/'=)4 COARSE AGGREGATE N/A FIELD DATA SUBMITTED BY ~S ADMIXTURE N/A MIX DATA SUBMITTED BY LATT COMPRESSION TEST RESULTS {NOMINAL CYLINDER SIZE S" X 12'°) Lab. Customer Type Dell DAniel Coml~laivl No. No. Curin9 T#ted St~h, I~i 45 94~1 L~B ~/09/94 7 4120 46 94~1 L~ ~/~/94 28 4740 47 94~1 LAB ~/~/94 28 5100 48 ~ 94~1 L~ ~D sp.~,~,c~,o.s 2~ 3~ REMARKS [~'Cylinders made by ALPHA representative. [] Cylinders made by Architect's or Contractor's representative. [:~linders picked up by ALPHA laboratory. [] Cylinders delivered to ALPHA laboratory. [~mpression test results comply with applicable specifications. with applicable specifications.