CF-Andrew Park 2-LR 940602 (8)
ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620-8911 REPORT OF PIER INSPECTION TESTED FOR: Rodman Excavation, Frisco, Texas Inc. OATE: 06/02/94 OUR REPORT NO.: 94001-25A ARCHITECT: Mesa Group, Inc. PROJECT: Andrew BrownJr. C~a,,~nity Park Phase II Coppell, Texas PIER INFORMATION: Pier Designation , Date Drilled Date Concrete Placed Shaft Diameter - Design / Actual, inches Bell Diameter - Design / Actual, inches Top Elevation - Design / Actual Bottom Elevation - Design / Actual Deviation from Design - Bottom Elevation (ft _~) Steel Reinforcement Used: Vertical (No. & size) Ties (No. & spacing) Splices (No. & location) Length of casing used, ft. Estimated Allowable Bearing Capacity, ksf Total Pier Length Drilled, ft: GRND SURF ET,EV REMARKS * See daily GENERAL CONTRACTOR:RO~ Excavation PIER CONTRACTOR: Long & Long Pier Drilling CONCRETE SURLIER: Lattimore 1 2 3 4 06/02 06/02 06/02 06/02 06/02 06/02 06/02 06/02 18" / 18" 18" / 18" 18" / 18" 18" / 18" 36" / 36" 36" / 36" 36" / 36" 36" / 36" 96.0 ! 96.0 96.0 / 96.0 96.0 I 96.0 96.0 / 96.0 85.0 ! 84.6 85.0/ 84.3 85.0 / 84.5 85.0 / 84.6 0.4 0.7 0.5 0.4 6~5'$ 6#5's 6#5's 6~5's #3@8" #3@8" #3@8" #3@8" N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 15.0 15.3 15.1 15.0 99.6 99.6 99.6 99.6 field report. Respect f~jJJ)j-6ubM~d