CF-Andrew Park 2-LR 940216ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620-8911
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR: RODMAN EXCAVATION, INC.
FRISCO, TEXAS
DATE:
02/16/94
PROJECT;
ANDREW BROWN JR.
COMMUNITY PARK PHASE II
COPPELL, TEXAS
OUR REPORT NO.
94001-7
TEST DATA:
i .Es. .0,.,0 o,,,.- .A.,....A. ,...Ac. '" ;%% I
:i NO / DATE NUMiil MOIITUII !OIY DINIITY MOIITUII~ DIY pCF Y COMPACTiONPII CCNT COMMENTe
I ll 02/16 SG 3 18.2 104.7 21.5 103 98 2-A
12 02/16 SG 3 18.2 104.7 21.6 102 98 2-A
13 02/16 SG 1 12.6 117.3 16.0 113 96 2-A
14 02/16 FG-2 3 18.2 104.7 21.0 101 96 i-A
15 02/16 FG-2 2 2i.4 97.4 22.3 97 100 1-A
16 02/16 FG-2 3 18.2 104.7 19.7 104 99 1-A
17 02/16 FG-2 3 18.2 104.7 21.9 103 98 1-A
TEST LOCATION:
11 50' S. & 175' E. OF HOME PLATE S.E. BALLFIELD CENTER FIELD
12 APPROXIMATELY 150' m. OF RESTROOM AREA SIDEWALK
13 APPROXIMATELY 100' 5. & 200' W. OF HOME PLATE S.W. BALLFIELD
14 APPROXIMATELY 175' N. & 175' E. OF HOME PLATE N.E. BALLFIELD
15 APPROXIMATELY 200' m. OF POINT "R" (PLAZA AREA) SIDEWALK
16 APPROXIMATELY 125' W. & 225' N. OF HOME PLATE N.W. BALLFIELD
17 100' E. & 75' N. OF HOME PLATE N.E. BALLFIELD
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4. CEMENT TREATED
A. TEST RESULTS COMPLY WITH SPECIFICATIONS
B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D, RETEST