Loading...
CF-Andrew Park 2-LR 921019ATEC Associates, Inc. 11356 Mathis Avenue Dallas, Texas 75229 (214) 556-2204 METRO 263-1681 CONCRETE TEST REPORT Project: Andrew Brown Park Date Smnpled: 10/t9/92 Client: Tony Crawtbrd Construction Our Report No.: 25-02-92-06928-23A Field Test Data Location of Pour when Sampled: 120' NORTH OF PARKWAY BLVD., WEST HALF OF DRIVEWAY Unit Weight (C-138) Supplier/Plant TX1 #31 Sampled By SCOTI' BERRY Delivery Ticket No. 41045 Time: Batched 10:06 AM Sampled 10:45 AM Truck Number 23 Load Size__ Temperature: Air 71°F Concrete 78°F Mix ID No. 8272, 3000 PS[ Slump: 5.0 in. Air Content % Water Added on Site 15.0 (C- ! 43) (C - 173/C-231 ) 10.0 cu. yds. Gals. Strength Test Results (C-39~ Type Specimens: CYLINDERS Area: 28.27 ind Beam Tent Dam (C-78} Lab Type Date Age. Failure Strength. Av~ Avg Span. Special NO. Curing Tested Days Load, lbs. PS[ Width, in. Depth. in. Preparation in. ! - 1275 LA B 10-26 7 59,U00 2090 [-1276 LAID 11-16 2~ 1-1277 LAB 11-16 28 1-1278 LAB 11-16 14 SPECIFIED STRENGTIi 28 3000 Remarks: Respectfully submitted,