Loading...
Westhaven-LR130517 ALPHA \ T E S T I N G REPORT OF FIELD 2209 Wisconsin Street,Suite 100 COMPACTION TESTS Dallas,Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR: Standard Pacific Homes- Irving DATE: 05/17/13 Irving, Texas PROJECT: Westhaven Phase 1 &2-Mass Grading OUR REPORT NO.: 130127-101 B Coppell, Texas TEST DATA: TECHNICIAN: Don Hinton TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY PERCENT COMMENT* NO. DEPTH NUMBER % PCF % PCF COMPACTION 2160 05/17/13 FG-4.0 2 9.2 124.4 11.4 119 96 1-A 2161 05/17/13 FG-3.0 2 9.2 124.4 11.0 121 97 1-A 2162 05/17/13 FG-2.0 2 9.2 124.4 11.7 119 96 1-A 2163 05/17/13 FG-1.0 2 9.2 124.4 10.3 119 95 1-A 2164 05/17/13 FG-5.0 2 9.2 124.4 10.2 121 98 1-A 2165 05/17/13 FG-4.0 2 9.2 124.4 10.3 121 97 1-A 2166 05/17/13 FG-3.0 2 9.2 124.4 10.8 120 96 1-A TEST LOCATION: 2160 Sanitary Sewer Line E at Station 4+02 2161 Sanitary Sewer Line E at Station 4+05 f I'./ 2162 Sanitary Sewer Line E at Station 4+08 lig 2163 Sanitary Sewer Line E at Station 4+10 �v 2164 Sanitary Sewer Line E at Station 6+15 0 ) 1 1 2165 Sanitary Sewer Line E at Station 6+18 2166 Sanitary Sewer Line E at Station 6+20 1. FILL *A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST 61471- [ Attef Abushakra,P.E. ALPHA TESTING,INC. Our test results and reports are for the exclusive use of the Client(and their designated recipients on file in our office)and shall not be reproduced and/or dstributed except with express approval of ALPHA.The use of our name and test results must receive our written approval.Test results and reports apply only to the samples tested and/or observed,and are not indicative of the qualities of apparently identical or similar specimens. ALPHA / TESTING REPORT OF FIELD 2209 Wisconsin Street,Suite 100 COMPACTION TESTS Dallas,Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No.813 TESTED FOR: Standard Pacific Homes- Irving DATE: 05/17/13 Irving, Texas PROJECT: Westhaven Phase 1 &2-Mass Grading OUR REPORT NO.: 130127-101C Coppell, Texas TEST DATA: TECHNICIAN: Don Hinton TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT* NO. DEPTH NUMBER % PCF % PCF COMPACTION 2167 05/17/13 FG-2.0 1 11.9 117.9 13.3 117 99 1-A 2168 05/17/13 FG-1.0 1 11.9 117.9 14.0 114 (7 1-A TEST LOCATION: 2167 Sanitary Sewer Line E at Station 6+00 2168 Sanitary Sewer Line E at Station 6+05 1. FILL *A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST G � 14' Attef Abushakra,P.E. ALPHA TESTING,INC. Our test results and reports are for the exclusive use of the Client(and their designated recipients on file in our office)and shall not be reproduced and/or astributed except with express approval of ALPHA.The use of our name and test results must receive our written approval.Test results and reports apply only to the samples tested and/or observed,and are not indicative of the qualities of apparently identical or similar specimens. ALPHA \ TESTING REPORT OF FIELD 2209 Wisconsin Street,Suite 100 COMPACTION TESTS Dallas,Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No.813 TESTED FOR: Standard Pacific Homes- Irving DATE: 05/17/13 Irving, Texas e/ PROJECT: Westhaven Phase 1 &2-Mass Grading OUR REPORT NO.: 130127-101 Coppell, Texas TEST DATA: TECHNICIAN: Don Hinton TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT* PCF % pCF COMPACTION 2146 05/17/13 FG-6.0 1 11.9 117.9 15.0 114 1-A 2147 05/17/13 FG-5.0 1 11.9 117.9 13.5 117 (97 99 1-A 2148 05/17/13 FG-4.0 1 11.9 117.9 13.0 117 r 99 1-A 2149 05/17/13 FG-3.0 1 11.9 117.9 14.0 115 \ 97 1-A 2150 05/17/13 FG-2.0 1 11.9 117.9 13.8 115 98 1-A C 2151 05/17/13 FG-1.0 1 11.9 117.9 12.0 118 ` 100 1-A 2152 05/17/13 FG-5.0 _ 1 11.9 117.9 13.0 116 99 1-A TEST LOCATION: 2146 Sanitary Sewer Line E at Station 2+00 2147 Sanitary Sewer Line E at Station 2+03 / 2148 Sanitary Sewer Line E at Station 2+05 2149 Sanitary Sewer Line E at Station 2+08 2150 Sanitary::::::: E:::::2+10I 251 Sanitary E 2+15 ffi // Yi° f / 2152 Sanitary Sewer Line E at Station 4+00 1. FILL *A. IN PLACE PERCENT MOISTURE AND PERCENT CO* TION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra,P.E. ALPHA TESTING,INC. Our test results and reports are for the exclusive use of the Client(and their designated recipients on file in our office)and shall not be reproduced and/or 6stnbuted except with express approval of ALPHA.The use of our name and test results must receive our written approval.Test results and reports apply only to the samples tested and/or observed,and are not indicative of the qualities of apparently identical or similar specimens. ALPHA 'VESTING REPORT OF FIELD 2209 Wisconsin Street,Suite 100 COMPACTION TESTS Dallas,Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No.813 TESTED FOR: Standard Pacific Homes- Irving DATE: 05/17/13 Irving, Texas PROJECT: Westhaven Phase 1 &2-Mass Grading OUR REPORT NO.: 130127-101A Coppell,Texas TEST DATA: TECHNICIAN: Don Hinton OPTIMUM MAXIMUM LAB IN PLACE IN PLACE TEST ELEV. SOIL ID PERCENT DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT* NO. DEPTH NUMBER % PCF % PCF COMPACTION 2153 05/17/13 FG-4.0 1 11.9 117.9 12.8 117 99 1-A 2154 05/17/13 FG-3.0 1 11.9 117.9 14.0 114 / 96 1-A 2155 05/17/13 FG-2.0 1 11.9 117.9 13.5 118 100 1-A 2156 05/17/13 FG-1.0 1 11.9 117.9 13.7 116 98 1-A 2157 05/17/13 FG-4.0 1 11.9 117.9 14.0 115 97 1-A 2158 05/17/13 FG-3.0 1 11.9 117.9 14.7 113 96 1-A 2159 05/17/13 FG-2.0 1 11.9 117.9 15.0 114 97 1-A TEST LOCATION: 2153 Sanitary Sewer Line E at Station 4+02 2154 Sanitary Sewer Line E at Station 4+05 2155 Sanitary Sewer Line E at Station 4+08 2156 Sanitary Sewer Line E at Station 4+10 2157 Sanitary Sewer Line F at Station 2+00 2158 Sanitary Sewer Line F at Station 2+02 2159 Sanitary Sewer Line F at Station 2+05 1. FILL 'A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra,P.E. ALPHA TESTING,INC. Our test results and reports are for the exclusive use of the Client(and their designated recipients on file in our office)and shall not be reproduced and/or ristributed except with express approval of ALPHA.The use of our name and test results must receive our written approval.Test results and reports apply only to the samples tested and/or observed,and are not indicative of the qualities of apparently identical or similar specimens.