CF-Andrew Park 2-LR 921015ATEC Associates, Inc.
11356 Mathis Avenue
Dallas, Texas 75229
(214) 556-2204
METRO 263-1681
CONCRETE TEST,REPQRT
Project: Andrew Brown Park
Date Sampled: 10/15/92
Client: Tony Crawford Construction
Our Report No.: 25-02-92-06928-20A
Field Test Data
Location of Pour when Sampled: 250' NORTH OF PARKWAY ST., 10' FROM EAST CURB
Unit Weight (C-138) Supplier/Plant TXI //31
Sampled By SCOTT BERRY Delivery Ticket No. 40252
Time: Batched 9:24 AM Sampled 10:30 AM Truck Number 203 , Load Size
Temperature: Air 78~F Coucrete 78aF Mix ID No. 8272
Slump: 5 in. Air Content % Water Added on Site 10.
(C- 143) (C- 173/C-231 )
10.0
cu. yds.
Ga£s.
Strength Test Results
(C-39)
Typ~ Specimens: CYLINDERS Area: 28.27 in.~ Beam Test Data (C-78)
Lab Typ~ Dat~ Age. Failure Strength. Avg Avg Span. Special
No. Curing Tcsted Days Load, Ibs~ PSI Width. in. Depth. in. Preparation
in.
1-1201 LA B 10-22 7 89.5(g~ 3170
1-1202 LAB I 1-22 28
1-1203 LAB 11-22 H
LAB
SPECIFIED STRF..N G TH 28 3000
Remarks:
Respectfully submitted,