Loading...
CF-Andrew Park 2-LR 921021ATEC Associates, Inc. 11356 Mathis Avenue Dallas, Texas 75229 (214) 556-2204 METRO 263-1681 CONCRETE TEST REPORT Project: Andrew Brown Park Date Sampled: 10/21/92 Client: Tony Crawford Construction Our Report No.: 25-02-92436928-25 Field Test Data' Location of Pour when Sampled: Paving slab, 41' E. & $5' N. of S.W. corner of West Parking area Unit Weight (C-138) Supplier/Plant TXI ~31 Sampled By SCOTT BERRY Delivery Ticket No. 41685 Tune: Bntched 8:15 AM Sampled ~;05 AM Truck Number 203 Load Size ,,, Temperature: Air ~F Concre~. 74~F Mix ID No. 8272, 3000 P.S.L Slump: 4 in. Air Content 5.0 % Water Added on Site O (C-143) (C-173/C-231) 10 cu. yds. Gals. Strength Test Results (c-:~) Type ~n~imens: CYLINDEI~ Area: 28.27 in? Beam Test DMa (C-Tg) Lab Type Date Age. Failure Strength, Avg AvI ~nn, Special No. Curing Teated Days Load, lbs. PSI Widlh, in. Deplh, in. Preparation in. 1-1~45 LAB 10-28 7 86,500 3060 1-1346 LAB 11-15 28 !-1347 LAB 11-18 28 2-1348 LAB 11-18 H SPEC~ 8TRF2~G~ll 28 ~000 Remarks: Respectfully submitted,