CF-Andrew Park 2-LR 921022 (2)ATEC Associates, Inc.
11356 Mathis Avenue
Dallas, Texas 75229
(214) 556-2204
METRO 263-1681
CONCRETE TEST REPORT
Project: Andrew Brown Park
Dnte Sampled: 10/22/92
Client: Tony Crawford Construction
Our Report No.: 25-02-92-06928-24A
Field Test Data
Location of Pour when Sampled: PAVING, 300' NORTH OF PARKWAY BLVD.; weber b~DE OF DRIVEWAY,
30' EAST OF PLAYGROUND'S EAST FENCE.
Unit Weight (C-138) Supplier/Plant TXI #31
Sampled By SCOTT BERRY Delivery Tncket No. 42195
Time: Bntched 10:20 AM Sampled ll:10 AM Truck Number 104 Load Size ....
Temperature: Air 7~°F Concrete $~F Mix ID No. ~7.72. 3000
Slump: S.0 in. Air Content % Water Added on Site
(C-143) (C-173/C-231)
cu. yds.
Gals.
Streneth Test Results
(C-39)
Type ~eeimem: CYLINDER~ Area: 28.27 in? Beam Te~t Data (C-78)
L~b Type Dat~ Age. Failur~ Strength, Avg Avg Spin, Spcehl
No. Curing Tesled Days Load, lbs. 1'~I Wldlh, in. Depth, in. Preparation
in.
1-1375 LAB 10-29 7 86,000 3040
1-1376 LAB 11-19 28
1-1377 LAB 11-19 28
1-1378 LAB 11-19 H
81~.,CIFI~) STRENGTH 28 3000
Remarks:
Respectfully submitted,
.... I' ' J II1'1'1'1